Specifications

All devices

EMC

Tested to ETS 300 683

Radio Components tested to EN

300 220-1

Environmental conditions

-10°C to 40°C, relative humidity

70% non-condensing for all units
except the external siren. Siren: -20°C
to 50°C, relative humidity 95% non-
condensing

Radio operational range

30m in a typical domestic

installation, range can vary depending
on building construction, device
positions and RF environment

Housings

ABS/polycarbonate

Siren

Siren output 

104dBA sound pressure @

1m minimum

Radio

433.92MHz AM super heterodyne

receiver with jamming detection 

Power supply 

6V, 4 x D alkaline cells. 3

years typical service life 

Passive infra red (PIR) detector

Alarm processing 

Microprocessor

controlled dual edge sequential pulse

count with pulse length discrimination

Radio

433.92MHz AM transmitter 

Power supply 

4.5V, 3 x AA alkaline cells.

3 years typical domestic service life, 1-

minute sleep timer 

Movement detection range 

15m, 110°

Door/window contact

Radio

Microprocessor controlled

433.92MHz AM transmitter 

Power supply 

3V, 2 x AAA alkaline cells. 3

years typical domestic service life 

Smoke detector

Radio

Microprocessor controlled

433.92MHz AM transmitter 

Power supply 

6V, 4 x AAA alkaline cells. 3

years typical domestic service life

Keyfob remote control

Radio

Microprocessor controlled

433.92MHz AM transmitter 

Power supply 

12V, 23A/MN21 alkaline

miniature "lighter" battery. 3 years

typical domestic service life 

Keypad remote control

Radio

Microprocessor controlled

433.92MHz AM transmitter 

Power supply 

3 x AAA alkaline cells. 3

years typical domestic service life

Help button

EMC

Tested to EN 300 220-1 and ETS

300 683

Environmental conditions 

-10°C to

40°C, relative humidity 70% non-

condensing

Radio operational range 

30m in a

typical domestic installation. Can vary

depending on building construction and

RF environment

Radio

Microprocessor controlled

433.92MHz AM transmitter

Power supply 

12V 23A/MN21 alkaline

miniature ‘lighter battery’. 3 years

typical domestic service life

0560

18

Specifications

All devices

EMC

Tested to ETS 300 683

Radio Components tested to EN

300 220-1

Environmental conditions

-10°C to 40°C, relative humidity

70% non-condensing for all units
except the external siren. Siren: -20°C
to 50°C, relative humidity 95% non-
condensing

Radio operational range

30m in a typical domestic

installation, range can vary depending
on building construction, device
positions and RF environment

Housings

ABS/polycarbonate

Siren

Siren output 

104dBA sound pressure @

1m minimum

Radio

433.92MHz AM super heterodyne

receiver with jamming detection 

Power supply 

6V, 4 x D alkaline cells. 3

years typical service life 

Passive infra red (PIR) detector

Alarm processing 

Microprocessor

controlled dual edge sequential pulse

count with pulse length discrimination

Radio

433.92MHz AM transmitter 

Power supply 

4.5V, 3 x AA alkaline cells.

3 years typical domestic service life, 1-

minute sleep timer 

Movement detection range 

15m, 110°

Door/window contact

Radio

Microprocessor controlled

433.92MHz AM transmitter 

Power supply 

3V, 2 x AAA alkaline cells. 3

years typical domestic service life 

Smoke detector

Radio

Microprocessor controlled

433.92MHz AM transmitter 

Power supply 

6V, 4 x AAA alkaline cells. 3

years typical domestic service life

Keyfob remote control

Radio

Microprocessor controlled

433.92MHz AM transmitter 

Power supply 

12V, 23A/MN21 alkaline

miniature "lighter" battery. 3 years

typical domestic service life 

Keypad remote control

Radio

Microprocessor controlled

433.92MHz AM transmitter 

Power supply 

3 x AAA alkaline cells. 3

years typical domestic service life

Help button

EMC

Tested to EN 300 220-1 and ETS

300 683

Environmental conditions 

-10°C to

40°C, relative humidity 70% non-

condensing

Radio operational range 

30m in a

typical domestic installation. Can vary

depending on building construction and

RF environment

Radio

Microprocessor controlled

433.92MHz AM transmitter

Power supply 

12V 23A/MN21 alkaline

miniature ‘lighter battery’. 3 years

typical domestic service life

0560

NoPb

WEEE

Note: Waste electrical products and 

batteries should not be disposed of with 

household waste. Please recycle where 

facilities exist. Check with your local 

authority or retailer for recycling advice.

2 Year Guarantee

Statement

This product is guaranteed for consumers against faulty workmanship, 
materials and function for a period of 2 years from the date of purchase 
providing the full installation and maintenance instructions are followed. 
Please keep your proof of purchase safe, this must be submitted when 
making a claim under this guarantee. 

Please  note  that  it  is  a  condition  of  this  guarantee  that  your  Yale 
product:

•  Has been correctly installed and maintained in accordance with the  

  Yale installation and maintenance instructions provided to you at  
  the time of purchase.

•  Has not been modified or damaged in any way.
•  Has not been subjected to unauthorized repairs.

Yale are responsible under this guarantee for repairing the product or 
replacing the product as we deem necessary. If there is fault with the 
product, please contact Customer Services on 01902 364647, who 

will give you the name of an expert and confirm what you need to do 

to make a claim under this guarantee.

Please do not carry out any repairs without our authority or by using an 
unauthorised expert. Any repairs or other works carried out without our 

authorization or by using an unauthorized expert will not be covered 

under this guarantee.

This guarantee is non transferrable and applies to products purchased 
in the United Kingdom only. This guarantee does not apply to normal 
wear and tear. This does not affect your statutory rights. A full copy of 
this guarantee is available upon request by writing to Yale UK, School 
Street, Willenhall, West Midlands. WV13 3PW or by visiting our website 
www.yale.co.uk.

Summary of Contents for HSA6500

Page 1: ... s instructions Be careful when using hand and power tools and follow the manufacturer s guidelines when using them Take care that the correct tools are used Wear goggles or protective clothing where required The external Siren is extremely loud please ensure you replace the cover and retreat to a safe distance before testing The dialling SMS facilities must only be used with persons who have cons...

Page 2: ...e operation Extend The System Extend the system in the future to increase your security or as your needs change For example add extra PIR detectors and extra door window contacts Choosing Location To minimise interference avoid locating devices close to metal framework glass electrical appliances especially wireless devices and electric cables Please note that the present of high density material ...

Page 3: ...ble Do not aim a PIR at this door or window PIR movement detector Mount in a position such that an intruder would normally move across the PIRs field of view Height should be between 1 9 and 2 metres above floor level Location in a corner will ensure wider room coverage Do not mount the PIR where its field of view will be obstructed e g by curtains ornaments etc Do not point directly at sources of...

Page 4: ...e backup battery duration the backlights will be switched off during mains power failure Remove the Sim card Power switch cover and switch the internal battery to on Insert a standard size GSM sim card not provided and replace the back cover Please ensure the sim card is not pin protected 2 Siren WARNING The siren is very loud be prepared Take care not to activate the siren tamper switch unnecessa...

Page 5: ...move the cover and insert the 3 AAA alkaline batteries as shown The Tx LED will flash briefly while components initialise Please note the Home button on the operating panel and the jumper switch inside do not move have no function on this model Smoke detector accessory Remove the cover and insert the four AAA batteries as shown Keyfob remote control accessory Slide off the battery cover insert the...

Page 6: ...t date time ok Press OK 3 to continue Set date press ok when done ok Press OK 3 to continue date setting 01 jan pqOK Set the current month using the p q key Press OK 3 to confirm setting Set the day using the p q key Press OK 3 to confirm setting After setting the day it will now prompt you to set the time Set the current time using the p q key Press OK 3 to confirm the hour follow by setting the ...

Page 7: ...e press the test learn button on all your accessories please add Siren later one at a time Every time a button is pressed the screen will prompt the device and you will need to press OK on the panel to acknowledge add It would then be reverted to the Exit Setup Repeat setup screen Please press the learn button on the next device and repeat the above steps Please ensure all the devices are added on...

Page 8: ...the learn test button the control unit should respond with a chime If the sensor signal reached the control unit the screen will briefly display dc zone01 b 6 Note this screen shot is use as example only The radio signal strength is shown by a number on the upper right 6 in this case this number ranges from 1 to 9 strongest Where possible please ensure sensor shows 3 or above for optimal performan...

Page 9: ... LED lights up it implies the two items are within range i Mounting using adhesive pads Clean the mounting surface with a suitable degreaser agent Please note that some surface or environment i e exposure to Sunlight maybe unsuitable for this mounting method Please use screw mounting in these cases Mounting using screws and wall plugs Loosen the bottom screw and open the door window contact Knock ...

Page 10: ...ing is disabled by default If you need Home arming function see Chapter 5 Home arm set i All accessories were pre set to entry attributes When the system is first armed user will have 30 seconds to exit the building System will ignore any sensors triggering in this duration If the system is already armed triggering any sensors will cause an entry countdown to begin When the alarm is triggered the ...

Page 11: ...t is selected you will be given 4 different options Sensor Test External Siren test Panel Siren test and Phone alert Sensor Test three beeps will sound during a screen self test This allows you to test the system without causing an alarm To test if the control panel is receiving a signal do one of the following depending on the device 1 Press Arm on the keypad 2 Press the test learn button on the ...

Page 12: ...te Controller emergency Button Help Button Remote Keypad dual emergency buttons Control Unit dual key emergency 1 and 3 keys Zone Type List Burglar When the system is in home or away armed mode and a burglar device is triggered a burglar alarm will be activated immediately A device set to burglar will not trigger an alarm during entry or exit delay periods Home Omit A home omit device will be igno...

Page 13: ...am the siren select Program siren under the Devices menu The following items are available in this menu Learn Siren Siren Tamp On Siren Tamp Off Confirm On Confirm Off Entry Snd On Entry Snd Off Learn Siren The control unit requires that at least one device is programmed into the system before the siren is added Put the siren into learn mode by pressing the learn button on the siren The siren LED ...

Page 14: ...sing 3 You will now be asked to name the PIN code The new code is now programmed P can be used to correct entry errors pressing P repeatedly will return you to the PIN code list User 1 code can only be changed and cannot be erased All other codes can be erased by selecting them and pressing 3 An error message will be shown if either an incorrect repeat code is used or a duplicate code is entered f...

Page 15: ...via voice dial or SMS These numbers are dialled SMS in order a maximum of 20 digits per number can be stored Only one number is required to enable the control unit to report over the telephone line 1 Use the pq keys to select a number from the list 2 Press 3 to confirm If there was a number already stored then you will be asked to change the number if the slot was empty you will be asked to enter ...

Page 16: ... Periodic SMS GSM signal SMS Keyword Reset GSM Periodic SMS Use this feature to avoid pre paid sim card credit expiring The credit in a pre paid GSM sim card PAYG often expires after 90 days of inactivity please check with your provider This option allows you to set an automatic SMS period between 10 days to 180 days By sending out SMS periodically it will keep the sim card live and avoid credit e...

Page 17: ...or press the disarm key followed by a PIN code on the control unit and keypad The keyfob will only disarm the system during entry time after an entry or away entry door window contact or PIR has been triggered 2 The control unit will sound two beeps The siren will beep twice and the strobe will flash side to side Alarm off will be displayed on the screen and the system is now disarmed 3 The contro...

Page 18: ...iated the control unit will wait for 15 seconds before dialling the preset phone numbers For voice call the control panel will wait 5 seconds then playback the messages in a loop It will first play the recorded address message then the pre recorded messages Burglar Emergency depending on the nature of the alarm and finally an acknowledgement request message The recipient should acknowledge the mes...

Page 19: ... 1 hour after which it will automatically arm again If longer is needed to fit the siren then simply repeat the steps above Leave the control unit in programming mode to stop the system responding to tampers If the control unit automatically times out re enter programming mode again i Enabling the system tamper After mounting the siren and detectors please enable the system tamper by 1 Press the m...

Page 20: ...d after an entry or away entry sensor is activated in the entry period Keypad Keypad code changing and setting The keypad comes with a factory default code of 0000 This code will need to be changed to the same code used in the control panel for the keypad to disarm the system To do this you will need to 1 Press the Panic button A key followed by factory default keypad code 0000 2 The LED will now ...

Page 21: ...riod If the smoke density is still over the alarm threshold then the smoke detector will remain in an alarm condition and it will repeat the local fire alarm with a radio fire alarm signal to the control unit Testing Smoke detector testing should be done on a regular monthly basis Pressing the test button will make the LED flash the audible sounder chime will send a radio test signal to the contro...

Page 22: ...disarmed take care not to confuse the two different conditions PIR battery change When the battery is low the LED will flash when any movement is detected The batteries are changed as follows 1 Put control unit into programming mode to prevent a tampered alarm 2 Loosen the case screw and remove PIR sensor from base to reveal three AAA batteries 3 Insert new alkaline batteries observing correct pol...

Page 23: ...ress a number key and check that the LED lights If the LED lights the new battery installation is successful screw keypad back on and the battery change is complete Help button battery change When the battery is low the LED will glow dimly when the button is pressed The battery is changed as follows 1 Loosen the bottom case screw and take button cover off base 2 Insert new CR2032 coin cell taking ...

Page 24: ...w it is less sensitive walking directly towards it PIR gives false alarms Check pets have no access to protected area Check that PIR is not pointed at sources of heat or moving objects e g fluttering curtains Check that PIR is not mounted above convector heaters or pointing directly at windows PIR LED flashes Batteries are low or the tamper switch is disturbed Check that the tamper switch spring i...

Page 25: ...ser Pincode followed by pressing 3 Stay in the programming menu Then disconnect the relevant sensor and replace batteries If the control panel times out and returns to Alarm off please follow the above steps again and repeat the process _____________________________________________ Complete Reset Procedure Reset to factory default setting The control panel can clear all programmed parameters by th...

Page 26: ...__________________ Jamming Interference detection User can enable Jamming interference detection should they feel it is a risk Detection via control panel From the panel s menu system select Adv Setting Jamming Det Enable Detection via External Siren Open up the siren Disable tamper first see earlier section and switch the Dip Switch 2 to On position Enabling these features increases the likely ho...

Page 27: ...ry Home Arm Entry Burglar No action Instant Burglar alarm Instant Burglar alarm No action No action No action Home Omit No action Instant Burglar alarm No action No action No action No action Entry Door Chime Start Entry Timer Start Entry Timer No action No action No action ...

Page 28: ...mming detection Power supply 6V 4 x D alkaline cells 3 years typical service life Passive infra red PIR Detector Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination Radio 433 92MHz AM transmitter Power supply 4 5V 3 x AAA alkaline cells 2 years typical domestic service life 1 minute sleep timer Movement detection range 15m 110 Door window co...

Page 29: ...HSA6060 HSA6080 HSA6090 HSA6091 HSA6500 HSA3045 HSA3070 Date 07 10 14 On behalf of ASSA ABLOY Ltd ASSA ABLOY Ltd School Street Willenhall West Midlands England WV13 3PW John Ward Director 17 Model HSA3400 HSA3020 HSA3060 HSA3010 HSA3050 HSA3045 HSA3080 HSA3030 HSA3070 EN 300 220 1 V2 1 1 2006 04 EN 301 489 1 V1 6 1 2004 12 EN 301 489 3 V 1 4 1 2002 08 EN 60 950 2001 A11 corrigendum 2004 ...

Page 30: ...creen below Panel Name Please give your panel a name Panel SIM The mobile number of your alarm panel SIM card PIN code Your alarm panel PIN code SMS Keyword Default is PROG You can change this Keyword from the panel option GSM setting SMS Keyword Once you have confirmed this setting select the panel and enter the main dashboard Please note that this app does not hold status information of your ala...

Page 31: ...etting page 14 Please note that the parameters shown does not reflect your actual alarm settings To confirm this setting press Save to send an SMS command to the panel Report Settings This menu has a list of 6 telephone numbers notify via voice dial or SMS These numbers are dialled SMS in order a maximum of 20 digits per number can be stored Only one number is required to enable the control unit t...

Page 32: ...D alkaline cells 3 years typical service life Passive infra red PIR detector Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination Radio 433 92MHz AM transmitter Power supply 4 5V 3 x AA alkaline cells 3 years typical domestic service life 1 minute sleep timer Movement detection range 15m 110 Door window contact Radio Microprocessor controlled...

Reviews: