25
_____________________________________________
Amber triangle LED illuminates
and warning beeps (every 30
seconds if enabled)
• There is a fault condition in your alarm system.
Note: this may be a simple fault that can easily be
rectified, for example replacing low batteries in an
internal PIR (movement) sensor.
• Please view the ‘fault log’ in the control panel to
determine what the issue is. This is the first option
in the programming menu. First press the ‘menu’
key and enter your user PIN code followed by
pressing
3
. Select ‘fault log’ followed by
3
. You
may need to scroll down using the
q
Key to
check if there are multiple faults in the system.
As an example, the display may read ‘DC Z01
tamper’, in which case you need to check the
mounting of the tamper spring on door contact
zone 01 to rectify this fault. In the case of low
batteries, you may see ‘IR Z02 LB’. Replacing the
batteries in PIR zone 02 will clear this particular
fault. Other reported faults include: Interference,
Tamper, Radio Device Low Battery and AC Power
Fail etc.
• If faults has not been cleared from the ‘fault log’, a
fault display will be show when the Arm or Home
Arm keys are pressed, with the device and fault
that is causing the problem.
• If more than one fault is present then individual
fault messages will be displayed sequentially at
2-second intervals.
IMPORTANT:
Please enter the programming menu first before
swapping out batteries- otherwise you will trip the
system tamper alarm.
Press the ‘menu’ key and enter your user Pincode
followed by pressing
3
. Stay in the programming
menu. Then, disconnect the relevant sensor and
replace batteries. If the control panel times out and
returns to ‘Alarm off’, please follow the above steps
again and repeat the process.
_____________________________________________
Complete Reset Procedure
Reset to factory default setting
The control panel can clear all programmed
parameters by the following sequence:
1
Power down control panel and remove the battery.
2
Apply power while holding down the
p
key.
3
Release the
p
key when a tone is heard, ‘
Enter
Code
’ will be displayed.
4
Enter the following key sequence:
pqpqpqpq
3
5
Press the
P
key.
6
All programmed parameters are reset to factory
default setting.
7
If more than 17 incorrect keys are entered, then
the unit will revert to normal Alarm On mode.
Note
• Once the ‘System Reset’ is executed, all the
programmed data is return to its default value and
all the programmed devices will be removed. User
will be prompt with the initial setup screen. Press
the learn button (see Chapter 2 for location) on
all accessories one at a time. Every time a button
is pressed, the screen will prompt the device
and you will need to press OK on the panel to
acknowledge/add. Please ensure you learnt in all
devices before exiting the initial setup screen.
Partial Reset Procedure
Reset to factory default setting however
keeping memory of all learnt sensors.
The control panel can clear all programmed
parameters by the following sequence:
1
Power down control panel and remove the battery.
2
Apply power while holding down the
p
key.
3
Release the
p
key when a tone is heard, ‘
Enter
Code
’ will be displayed.
4
Enter the following key sequence:
pqpq
3