46
EN
Fitting and installation
Emergency Open module 1386D00
Fig. 34 :
Connections of the
Emergency Open
button
8
9
10
11
7
6
5
4
3
2
1
12
off
on
2
1
12
off
on
1
2
J1
J2
Front page
Back page
A
Attention!
Propy damage from connection
with USB devices:
The jack is not
a USB jack and is only intended
for connecting the
ePED Service
Interface USB
1386–SIF.
1
Connection jack for
ePED Service Interface USB
2
Cover contact
3
SYSCON 5
4
SYSCON 4
5
SYSCON 4
6
Screw-type terminal strip
1 CAN_H
2 CAN_L
3 V
B
+
4 GND
5
In1
V
B
+
6 In1
GND
7
In2
V
B
+
8 In2
GND
In1
= Temporary release
In2
= Fire alarm
7
Screw-type terminal strip
Potential-free
relay
8
1
Hi-O terminating resistor
2
Hi-O group switch,
must be set to
Off
position
1
2
3
4
5
6
7
8
I
Note!
Configuration:
The connections can be configured with the
ePED
®
Service Software
(
D01104xx ePED
®
Service Software
Manual).