background image

4

MP6600 Series Multi-Point Lock

Installation Instructions

Used with VN1 Escutcheon Trim and V Series Indicators

FM556  08/20

Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or 
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

For installation assistance contact Corbin Russwin

1-800-543-3658 • [email protected]

Rehanding Indicator (if required)

Verify hand and bevel of door.  See Figure 2 below.

LH

 

Left Hand

Hinges Left

Open Inward

LHRB 

Left Hand

Reverse Bevel

Hinges Left

Open Outward

RH

Right Hand

Hinges Right

Open Inward

RHRB 

Right Hand

Reverse Bevel

Hinges Right

Open Outward

Note:

Stand outside of locked door when determining door hand.

Next, verify inside and/or outside indicators are handed 
correctly, using Spindle Cam Position chart. (Figure 3) 

If they are handed correctly, skip to Step 5 

"

Prepare Door". 

If they are not handed correctly:

1.  Remove indicator back plate by pulling out from top slot, 

then remove spindle cam from assembly. (Figure 4)

2.  Position spindle cam in correct direction for door 

hand. (Figure 3)

Important:

• 

 For thumbturn indicators, make sure thumbturn is 
positioned in 12 o’clock direction as shown. (Figure 5)

3.  Slide spindle cam post into the correct slot of the 

display slide. (Figure 4)

4.  Re-seat back plate into original position.

5.  Return indicator to 

v

acant/unlocked position for installation

Door Hand: RH / RHRB

Door Hand: LH / LHRB

Outside Indicator

Inside Indicator

Inside Indicator

Outside Indicator

Spindle Cam Position for Locks with Deadbolt (*and 56 function)

Door Hand: RH / RHRB

Door Hand: LH / LHRB

Outside Indicator

Inside Indicator

Inside Indicator

Outside Indicator

Spindle Cam Position for Locks without Deadbolt (*except 56 function)

Figure 2 

 

Figure 3 

 

Spindle 
cam

Display 
slide slot

Plate slot 
for removal

Back plate

Thumbturn 
position

Figure 4 

 

Summary of Contents for Corbin Russwin MP6600 Series

Page 1: ...roup Inc is prohibited FM556 08 20 For installation assistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com WARNING This product can expose you to lead which is known...

Page 2: ...sion of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited For installation assistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com TOC Table of Contents 1...

Page 3: ...assaabloy com 1 Tools Required 2 Indicator Variants Depending on function and option ordered indicators are provided in the following variations these instructions detail how to install with cylinder...

Page 4: ...ing Spindle Cam Position chart Figure 3 If they are handed correctly skip to Step 5 Prepare Door If they are not handed correctly 1 Remove indicator back plate by pulling out from top slot then remove...

Page 5: ...lock is in unlocked state control hub slot should be vertical Also verify indicator is in vacant unlocked position 2 Align trim posts with diagonal holes in door be sure lever is horizontal Slide out...

Page 6: ...op Figure 10 If double cylinder function is used repeat steps 1 and 2 for second cylinder Removable Core or Interchangeable Core cylinders require a control key key stamped with C to remove and instal...

Page 7: ...icator Window 1 3 Indicator Display Assembly Green Unlocked Red Locked 1 Indicator Display Assembly Green Vacant Red Occupied Indicator Display Assembly Green Unlocked Icon Red Locked Icon Indicator D...

Page 8: ...rdware Group Inc All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited For installation assistanc...

Reviews: