5
Installation Instructions
Exit Devices
FM572 10/22
Copyright © 2022, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
ED2400 & ED2400(A) Series Surface Vertical Rod
2
General Information, continued
Lift block
Vertical lifter
assembly
(4) 8-32 x 3/16" PRHMS
Vertical lifter
assembly
(4) 8-32 x 3/16" PRHMS
RHR Device
LHR Device
Remove four (4) screws and
vertical lifter assembly. Rotate
device to opposite hand (180˚).
Insert lifter assembly under
lift block and re-install screws.
Note
Lifter must fit under lift block as
shown. ( 1)
Change Hands
a
1/4-20 Sex Nut Option
b
Recommended for wood
composite or unreinforced
metal doors. (Figure 2)
Figure 2
Note
Standard for Fire
Rated doors.
Device
Quantity
Size
No trim
8
1/4 - 20
With trim
6
Rod Extension Options
c
Figure 3
• 2" (51 mm)
• 6" (152 mm)
• 12" (305 mm)
Figure 1
RHR Door
LHR Door