6) Installation Instructions (Contin
ued)
4. Configuring the Fail Safe/Fail Secure and RX* DIP switch settings:
Check polarity:
(red) wire
Please note that the lock must be cycled once in order for setting changes to take effect.
5. Install Lock Body into Door:
a. Plug mortise lock harness into
ElectroLynx
®
harness in door (Fig. 5).
Important: Door must remain open during
installation. Use door stop.
Install, but do not tighten two #12 x 1”
b.
combination screws through lock body
(Fig. 5).
Outside Face of Door
(2) #12 x 1”
Fig. 5
Do not tighten
8
EcoFlex
™
Electrified Mortise Locks (NAC-)
with High-Security Monitoring Options
Installation and Wiring Instructions
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express
written permission of ASSA ABLOY Access and Egress Hardware Group, Inc.
is prohibited.
*RX output only configurable for locks
with end-of-line resistance monitoring.
Default is normally open.