Grade 1 Key-In-Lever VR Lever Lock
CL3100 Series
Installation Instructions
FM345 01/19
For Installation Assistance contact Corbin Russwin
1-888-607-5703 • [email protected]
Copyright © 2016, 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
13
1. Align mounting plate on both sides of the door with the five (5) holes prepared in the door.
Note
The dimple faces the door edge.
2. Install screw from the opposite side of the door.
Note
Be sure to install mounting plate aligning clearance hole and threaded hole.
2A. Install washer and screw from the opposite side of the door
(half dummy).
3. Install four (4) surface screws (#4 flat head Phillips screws)
in the mounting plate.
4. Align and place the rose on both sides of the door.
5. Place and tighten rosette with CL3100 wrench.
6. Install lever.
7. Tighten 6 lobe security set screws.
d
Remove Cylinder
1. Remove security screw on outside of lever with 6 lobe wrench.
2. Insert key and rotate key 45° clockwise; keep key in this position.
3. Using screwdriver, tighten the security attachment screw clockwise
until it clears the lever.
4. Remove lever and remove key.
5. Remove cylinder from lever and install new cylinder.
6. Reinstall lever following steps on previous page.
Figure 23
Cylinder Removal
15
Dummy Trim Installation
CL3150/70 Half/Full Dummy Trim C, E and K Rose
14
Installation: CL3100 Lever Lock with High Security Lever (cont.)
Figure 24
Dummy Trim Installation C, E and K
PLEASE REFERENCE
TEMPLATE: T31194
2
4
3
1
6 lobe security
wrench
6 lobe security
wrench
45°
1
3
4 rose
5 rosette
6
7
7
clearence
hole
dimple
5
threaded hole
re v erse of flange
2
1
3
rose 4
rosette 5
6
5
7
7
2A
Half
Dummy
Trim
Full
Dummy
Trim
4. Rose
4. Rose
5. Rosette
5. Rosette
Clearance
hole
Threaded hole
reverse of flange
Dimple