Grade 1 Key-In-Lever VR Lever Lock
Installation Instructions
CL3100 Series
FM345 01/19
For Installation Assistance contact Corbin Russwin
1-888-607-5703 • [email protected]
Copyright © 2016, 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
10
13
IC Cylinder and Levers - Installation / Removal
Corbin Russwin Interchangeable Cores (C6, CL6, CT6, CTP, C7, CL7, CT7)
Small Format Interchangeable Cores SFIC (M08). Schlage LFIC (M69). Yale LFIC (YRC, YRC7)
a
Remove IC Core
1. Insert control key and turn counter clockwise until stop is reached.
2. With key in this position, pull out core.
3. Remove key.
2
1
Figure 16
Core Removal
b
Remove IC Core Lever
1. Remove cylinder (as above).
2. Remove 6 lobe security set screw.
3. Use a flat blade screwdriver to rotate cam within lever sleeve 45°
clockwise to align lever catch slot with lever catch button. (See cam
orientation page 7 step 7).
4. Depress catch and remove lever.
Figure 17
Core Lever Removal
c
Install IC Core Lever
1. Assemble lever onto sleeve.
Note
If IC core is available, insert it into the lever first (see 13D).
2. Use a flat blade screwdriver (or, with the IC core in the
lever, use the key and turn to engage the tailpiece and
slot) to rotate cam within lever sleeve 45° clockwise to
align wide slot with lever retainer catch.
3. Push lever until catch engages. Check engagement.
4. Secure with 6 lobe security set screw.
Figure 18
Core Lever Installation
3
2
4
PRESS CATCH
5
Press catch
2
4
3
PRESS CATCH
3
1
OR
Press catch