4
CL33600 Series Cylindrical Lock
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
12VDC System
• Reader Draw = 150mA
• 12VDC Solenoid Draw = 500mA
• Total System Draw = 650mA
24VDC System
• Reader Draw = 150mA (maximum)
• 24VDC Solenoid Draw = 250mA (normal state)
• Total System Draw = 400mA
The Corbin Russwin Access 600 TCRNE1 Series cylindrical lock is designed to interface with existing Wiegand
Electrical Access Control (EAC) panels. The reader requires 12 or 24VDC for power and is compatible with HID
iCLASS SE
®
13.56 MHz technology. The Access 600 technology is designed around Corbin Russwin’s Grade 1
hardware. The cylindrical lock (with external DPS, Door Position Switch) comes with complete inside REX
(request to exit) monitoring and is available in 12VDC or 24VDC. Weatherseal gaskets are also included for
outdoor applications.
The Access 600 reader provides visual (LED) and audible indication of lock state (locked/unlocked).
• Latch – Stainless steel, ½” (13mm) throw
Optional: ¾” (19mm) throw deadlocking
fire latch for pairs of doors
• Deadlocking latch prevents manipulation when door closed
• Door Thickness – 1-3/4” (44mm) to 2” (50mm) standard
Optional 2” (50mm) to 2-1/4” (57mm) optional
• Outside lever controlled by reader or key retracts latch
• Inside Lever produces REX (request to exit) signal
• Fail Safe or Fail Secure operation (must specify)
• UL fire listed
• Wire from EAC Panel to door must be shielded with a drain.
Drain terminated at EAC Panel controller
• Complete monitoring of door (External DPS supplied)
• Wires directly to EAC Panels
• McKinney QC12 Hinge with ElectroLynx
®
plug and play
2) General Description
3) Features
4) Regulatory Specifications
Destructive Attack
Level I
Line Security
Level I
Endurance
Level IV
Standby Power
Level I
• UL 294 Access Control Performance Ratings:
• UL294 6th Edition (Access Control System Units)
• This product meets the requirements of CAN/ULC-S319-05 Equipment Class I
• ANSI/BHMA A156.25 Listed Grade 1 Compliant ANSI/BHMA A156.25 Listed Grade 1 Compliant
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical
Code (CEC), Part I, Safety Standard for Electrical Installations, local codes, and the authorities having jurisdiction.
• Supported credentials:
• iCLASS
®
• iCLASS SE
®
(SIO-enabled)
• iCLASS
®
Seos
®
• HID SIO on MIFARE
®
Classic
• HID SIO on MIFARE DESFire
®
EV1
• NFC-enabled mobile phones
Summary of Contents for Corbin Russwin Access 600 CL33600 TCRNE1 Series