CL33600 Series Cylindrical Lock
15
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Note: Once electrical wiring has been successfully
completed according to proper application, perform
the following step:
a. Turn power ON.
b. Verify LED located on reader is ON (Red or Green
depending on reader configuration (See reader LED
Configuration).
c. Present proximity credential and verify LED and
sounder activity.
d. Verify valid card read at EAC Panel.
e. Verify system operation functions; i.e., when prox
credential is presented to reader that the door unlocks.
8) Operational Check
Before closing door test for cylinder function of lock cylinder
and Inside lever:
a. Insert key into cylinder and rotate.
b. The key will retract the latch. Key should rotate freely.
c. Inside lever retracts latch.
d. Close door, ensure latch fully extends into strike
and does not bind.
Electrical
Mechanical
Feature
WT1
WT2
12 or 24VDC solenoid
lock voltage adjustable
X
X
Operates as Fail Safe or
Fail Secure
X
X
"Learn" mode allows
testing of specific cards
without programming at
the panel level
X
X
Card reader data inte-
grity is validated at test
unit
X
X
Works with SE LP10
X
X
Displays detailed
Wiegand data, including
hexadecimal string and
total bits received
X
Displays measured end-
of-line resistor values
(if applicable)
X
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product’s features and capabilities.
Wiegand Test Unit