7) Installation Instructions (Continued)
Fig. 5a
Fig. 5b
Outside Face of Door
5.
Installing Lock
- Feed lock body and wire through 2-1/8” diameter hole from outside of door (Fig. 5a).
Be sure latch engages lock body as shown (Fig. 5b):
Important: Door must remain open during installation.
Use door stop
6.
Install Inside Spring Cassette:
a. Feed lock body wires and cassette (REX) wires in slot on face of door (Fig. 6a)
Note: Be careful to keep wires in slot cut into door.
b. Tightening using two #12-24 screws.
Note: DO NOT PINCH wires when tightening.
Fig. 6a
Fig. 6b
Inside Face of Door
Keep wires in slot:
DO NOT pinch under
Spring Cassette
Lock Body Wires
REX Wires
Ground Wire
Spring Cassette
Summary of Contents for Corbin Russwin Access 600 CL33600 TCRNE1 Series