ML20700 PWI/PIP Series Mortise Lock
24
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
1. Install Inside Mounting Plate
Fig. 10a
Mounting Plate
(4) #8 - 32 x 1-7/8" Flat
Head Machine Screws
(2) #8 - 3/8" flat head
Wood Screws
(4) #8 - 32 x 1-7/8" Flat
Head Machine Screws
Note: Cable lengths exaggerated for illustrative purposes.
1. On the inside of the door, position the mounting plate over the indicated holes.
2. Feed reader, ground ring terminal and DPS cables through central opening on mounting plate (Fig. 11).
3. Route PoE Harness through alternate opening (to the right of the central opening).
4. Route ground ring terminal from lock body through bottom of mounting plate and attach to bottom left
corner using (1) #8-32 x 1-7/8” flat head machine screw.
5. Insert other three #8-32 x 1-7/8” flat head machine screws and tighten, fastening the outside escutcheon
to the door (Fig. 11).
IMPORTANT
: If the following step is skipped, the product
will not be UL-compliant:
6. Attach two (2) #8 x 3/8” flat head wood screws for
wood doors or (2) #8-32 x 3/8” flat head machine
screws for metal doors (Fig. 11).
7) PWI (Wireless) Wiring & Installation