Aperio

®

 Online Mechanical Installation Guide, Document No: ST-001323-B Date: 21 februari 2014

25

Aperio

®

Online

5  Configuration and Connection of Cables

AH15 (RS-485)

This chapter describes how to perform a default 

configuration of an AH15 communication hub 

using the RS-485 interface.

Configuration of the communication hub to the 

EAC includes setting the DIP switches, connecting 

it to the RS-485 bus and connecting it to power 

supply, according to the applicable section below.

Configuring the DIP switches

8-24V

GND

GREEN

RED

DATA0

DATA1

RS485 B

RS485 A

1

2

3

4

5

6

7

8

ON

DIP

Abbr.

Description

8

TERM

Activates termination of EAC bus

7

UP

Activation of pull up resistor

6

DOWN

Activation of pull down resistor

5

A4

Manual EAC Address

4

A3

Manual EAC Address

3

A2

Manual EAC Address

2

A1

Manual EAC Address

1

A0

Manual EAC Address/Automatic 

pairing (DIP 1-5 = OFF)

DIP 1-5 – Selecting the EAC address/Automatic 

paring

The DIP 1-5 has two functions, either automatic 

paring mode, or manual selection of EAC address 

on the RS485. Default configuration is to select 

an address according to below. By doing so 

automatic pairing will be deactivated. 

 ∙

DIP 1-5 – Pairing mode

 

If DIP 1-5 are set to OFF, pairing mode will be 

activated. This means that after powering on 

the communication hub it will automatically 

try to pair with locks within range. Automatic 

pairing will only be made with unpaired locks. 

The automatic pairing procedure is described in 

ref [2], Aperio Online Programming Application 

manual.

 ∙

DIP 1-5 – Selecting EAC address

 

It is possible to select an address 1-31 for the 

AH15 communication hub using the DIP switch. 

For mixed modes, see section 

"Selecting the 

correct EAC address (AH15/AH30)" on page 42 

for more details and advance options.

  The communication hub must be power 

cycled after changing the address, since 

the state of the DIP switch is read only at 

startup.

Figure 7. 

Address  

allocation in a default 

installation

Lock

0x01

Lock

0x02

Lock

0x2F

AH15

0x01

AH15

0x02

AH15

0x2F

Address 1-31 (-63 using the Programming application)

. . .

. . .

. . .

Lock

0x03

AH15

0x03

Lock

0x11

AH15

0x11

Lock

0x12

AH15

0x12

Lock

0x21

AH15

0x21

Summary of Contents for Aperio AH15

Page 1: ...The global leader in door opening solutions Aperio Online Mechanical Installation Manual Document No ST 001323 C Issue date 21 February 2014 ...

Page 2: ...ence 6 4 Mechanical Installation 7 Mechanical installation AH15 7 Installation examples for AH15 communication hub with E cylinder locks 9 Installation examples for AH15 communication hub with other type of locks 14 Mechanical installation AH20 30 40 17 Installation examples for AH20 30 40 communication hub 19 5 Configuration and Connection of Cables 25 AH15 RS 485 25 AH15 Wiegand 28 AH20 Wiegand ...

Page 3: ...ual software for setup of Aperio products for final use with an EAC Applicable Products This manual can be used for all versions of communication hubs Product availability The products included in this manual may not be available on all markets Please check your local ASSA ABLOY company for details Aperio support in the EAC system Note that the Aperio support may vary depending on the Aperio commu...

Page 4: ...Aperio USB radio device connected to one of its USB ports The USB radio device enables the application to connect via a Communication Hub to the door lock The lock communicates via the Communication Hub either with the EAC or with the Programming Application Read more in the Aperio Online Programming Application Manual Regulatory and security information Refer to the Programming Application manual...

Page 5: ...antenna is used the radio coverage backwards is limited to 0 5 m 3 ft for AH15 and 3 m 10 ft for AH20 30 40 The coverage also depends on the type of wall it is installed on When the external antenna is used the radio coverage will be focused perpendicular to the direction of the antenna and in some directions the range may decrease However the maximum range will not increase See section Radio cove...

Page 6: ...Fi WLAN routers and other radio transmitters operating in the 2 4 GHz band should be kept at least 3 5 meters 12 feet from the Communication Hub and lock Other possible sources of interference include microwave ovens electric motors wireless emergency exit signs and other high power electrical equipment Keep at least 3 5 meters 12 feet distance to Communication Hub or lock In difficult environment...

Page 7: ...ine EAC system This chapter also describes how to connect the communication hubs to the power supply Mechanical installation AH15 Minimum distance between AH15 communica tion hubs If necessary several communications hubs can be positioned together with a minimum of 0 2 meter in between the hubs or use one AH30 communication hub to pair with all three locks X X 0 2 m 8 in X Figure 3 Minimum distanc...

Page 8: ...rallel to the direction of the lock and as close to the lock as possible The following pages show typical installations based on field experience that will give a good result for radio link quality The colors indicate which hubs and Aperio door locks that belong together 4 m 13 ft Parallel 5 m 16 ft The AH15 communication hub can be mounted according to the following figure AH15 Communication hub ...

Page 9: ...nical Installation Guide Document No ST 001323 B Date 21 februari 2014 9 Aperio Online Installation examples for AH15 communication hub with E cylinder locks Short long Corridors Alternate installation 5 m 16 ft 5 m 16 ft ...

Page 10: ...Aperio Online Mechanical Installation Guide Document No ST 001323 B Date 21 februari 2014 Aperio Online 10 High ceiling 5 m 16 ft 5 m 16 ft 4 m 13 ft Low ceiling 5 m 16 ft 5 m 16 ft 1 5 4 m 5 13 ft ...

Page 11: ...e Mechanical Installation Guide Document No ST 001323 B Date 21 februari 2014 11 Aperio Online Square rooms 5 m 16 ft 5 m 16 ft Alternate installation with ceiling placement 5 m 16 ft 5 m 16 ft 5 m 16 ft 5 m 16 ft ...

Page 12: ...Aperio Online Mechanical Installation Guide Document No ST 001323 B Date 21 februari 2014 Aperio Online 12 Open space environments 5 m 16 ft 5 m 16 ft 5 m 16 ft 5 m 16 ft ...

Page 13: ...nting holes vertically aligned and as close to the lock as possible The following pages show typical installations based on field experience that will give a good re sult for radio link quality The colors indicate which hubs and Aperio door locks that belong together The AH15 communication hub can be mounted according to the following figure AH15 Communication hub installed on a wall with mounting...

Page 14: ...ation Guide Document No ST 001323 B Date 21 februari 2014 Aperio Online 14 Installation examples for AH15 communication hub with other type of locks Corridors 4 m 13 ft 5 m 16 ft Alternate installation on same wall 4 m 13 ft 5 m 16 ft ...

Page 15: ...Aperio Online Mechanical Installation Guide Document No ST 001323 B Date 21 februari 2014 15 Aperio Online Square rooms 5 m 16 ft 5 m 16 ft Alternate installation on same wall 5 m 16 ft 5 m 16 ft ...

Page 16: ...Aperio Online Mechanical Installation Guide Document No ST 001323 B Date 21 februari 2014 Aperio Online 16 Open space environments 5 m 16 ft 5 m 16 ft ...

Page 17: ... under good conditions free air between the units and limited radio interference from other transmitters the distance can be extended The following pages show typical installations based on field experience that will give a good re sult for radio link quality The colors indicate which hubs and Aperio door locks that belong together The AH20 30 40 communication hub can be mounted according to the f...

Page 18: ... does not extend the maximum range which is still 15 m 50 ft An example of a situation where external antenna could be used is when the placement options are limited for the communication hub The following figure illustrates the difference in radio pattern for external and internal antenna Note that this is only an simplified picture of the radio reception for each antenna showing the theoretical ...

Page 19: ...ine Mechanical Installation Guide Document No ST 001323 B Date 21 februari 2014 19 Aperio Online Installation examples for AH20 30 40 communication hub Short Corridors 15 m 50 ft Alternate installation 15 m 50 ft ...

Page 20: ...Aperio Online Mechanical Installation Guide Document No ST 001323 B Date 21 februari 2014 Aperio Online 20 Long corridors 30 m 100 ft Alternate installation 30 m 100 ft ...

Page 21: ...Aperio Online Mechanical Installation Guide Document No ST 001323 B Date 21 februari 2014 21 Aperio Online High ceiling 15 m 50 ft 5 m 16 ft Alternate installation 15 m 50 ft 5 15 m 16 50 ft ...

Page 22: ...Aperio Online Mechanical Installation Guide Document No ST 001323 B Date 21 februari 2014 Aperio Online 22 Low ceiling 15 m 50 ft 1 5 5 m 5 16 ft ...

Page 23: ...o Online Mechanical Installation Guide Document No ST 001323 B Date 21 februari 2014 23 Aperio Online Square rooms 15 m 50 ft 15 m 50 ft Alternate installation with light wall material 15 m 50 ft 20 m 50 ft ...

Page 24: ...Aperio Online Mechanical Installation Guide Document No ST 001323 B Date 21 februari 2014 Aperio Online 24 Open space environments 15 m 50 ft 15 m 50 ft Alternate installation 15 m 50 ft 15 m 50 ft ...

Page 25: ...tomatic paring mode or manual selection of EAC address on the RS485 Default configuration is to select an address according to below By doing so automatic pairing will be deactivated DIP 1 5 Pairing mode If DIP 1 5 are set to OFF pairing mode will be activated This means that after powering on the communication hub it will automatically try to pair with locks within range Automatic pairing will on...

Page 26: ...ition for all communication hubs except for the communication hub at the end of the bus which must have DIP switch 8 in ON position The RS 485 bus must be terminated on the EAC side EAC system A B A Termination enabled B A B A B Hub 1 DIP 6 OFF DIP 7 OFF DIP 8 OFF Hub 2 DIP 6 OFF DIP 7 OFF DIP 8 OFF Hub N End of Bus DIP 6 ON DIP 7 ON DIP 8 ON For a star connection set DIP 6 and 7 in ON position fo...

Page 27: ...n the EAC system a maximum of 32 units 31 communication hubs plus the EAC when using the DIP Switch for RS 485 addressing can be connected to the same bus Connect all RS485 A connectors together and all RS485 B connectors together depending on connection type see Figure 8 and Figure 9 on page 26 Connecting to supply voltage Connect the wires to 8 24 VDC 0 9 W and GND ground on the communication hu...

Page 28: ...ce component 3 A2 Controls addition of parity bits on transmitted credentials One even parity bit before and one odd parity bit after the actual credentials OFF Addition of parity is disabled Credentials are transmitted as received ON Addition of parity bits is enabled 2 A1 Reserved for future use Set to OFF 1 A0 Controls use of Red LED signal for access decision ON Red LED is used OFF Red LED is ...

Page 29: ...ired Yes Yes Figure 10 Dip Switch 1 OFF Access decision logic with single LED signal Red LED active Data from RFID reader Transmit via Wiegand interface On completion start timer 1 5 s Signal access denied to lock Signal access granted to lock No No No No No Yes Yes Green LED active Red LED active Timer expired Exit without access decision to lock This means that override credentials will be used ...

Page 30: ...t to OFF DIP 3 Parity bit Note Transmitted credentials may include parity anyway although addition of parity is disabled in the Hub Wiegand EAC interface component The reason is that parity bits are usually already included on the credential DIP 4 Byte Order Note This setting is ignored if the credential length does not make up complete bytes Note The byte order received as input to the Hub Wiegan...

Page 31: ...onnect to a lock control relay output on EAC system RED Wiegand Red LED signal Input to communication hub Used for access decision Wiegand Red LED output on EAC system Alternatively leave unconnected if signal is selected not to be used by DIP switch 1 DATA0 Wiegand Data 0 signal Output from communication hub Used to transmit credentials Wiegand Data 0 on EAC system DATA1 Wiegand Data 1 signal Out...

Page 32: ...d as input to the Hub Wiegand EAC interface component 3 A2 Controls addition of parity bits on transmitted credentials One even parity bit before and one odd parity bit after the actual credentials OFF Addition of parity is disabled Credentials are transmitted as received ON Addition of parity bits is enabled 2 A1 Set to OFF Reserved for future use 1 A0 Controls use of Red LED signal for access de...

Page 33: ...ired Yes Yes Figure 13 Dip Switch 1 OFF Access decision logic with single LED signal Red LED active Data from RFID reader Transmit via Wiegand interface On completion start timer 1 5 s Signal access denied to lock Signal access granted to lock No No No No No Yes Yes Green LED active Red LED active Timer expired Exit without access decision to lock This means that override credentials will be used ...

Page 34: ...on time out in this case DIP 2 Future use Note This DIP must always be set to OFF DIP 3 Parity bit Note Transmitted credentials may include parity anyway although addition of parity is disabled in the Hub Wiegand EAC interface component The reason is that parity bits are usually already included on the credential DIP 4 Byte Order Note This setting is ignored if the credential length does not make ...

Page 35: ...APPLICABLE DATA1 Wiegand Data 1 signal Output from communication hub Used to transmit credentials Wiegand Data 1 on EAC system DATA0 Wiegand Data 0 signal Output from communication hub Used to transmit credentials Wiegand Data 0 on EAC system RED Wiegand Red LED signal Input to communication hub Used for access decision Wiegand Red LED output on EAC system Alternatively leave unconnected if signal...

Page 36: ... 4 5 6 7 8 9 10 ON S101 J100 J103 S100 Relays Description Relay 1 K500 DPS Door Position Sensor Relay 2 K501 RX Request to exit Relay 3 K502 Battery Alarm Output Relay 4 K503 Tamper Alarm Output Lock Jammed Relay Contacts Description NCL Normal Closed COM Common NOP Normal Open Relay max voltage 30 VDC Relay max current 1 A resistive load Connecting to supply voltage Connect the wires to 8 24 VDC ...

Page 37: ... 3 A2 Manual EAC Address 2 A1 Manual EAC Address 1 A0 Manual EAC Address Automatic pairing DIP 1 5 OFF DIP 1 5 Selecting the EAC address Automatic paring The DIP 1 5 has two functions either automatic paring mode or manual selection of EAC address on the RS485 Default configuration is to select an address according to below By doing so automatic pairing will be deactivated DIP 1 5 Pairing mode If ...

Page 38: ...x17 0x27 0x37 0x47 0x57 0x67 0x77 1000 0x08 0x08 0x18 0x28 0x38 0x48 0x58 0x68 0x78 1001 0x09 0x09 0x19 0x29 0x39 0x49 0x59 0x69 0x79 1010 0x0A 0x0A 0x1A 0x2A 0x3A 0x4A 0x5A 0x6A 0x7A 1011 0x0B 0x0B 0x1B 0x2B 0x3B 0x4B 0x5B 0x6B 0x7B 1100 0x0C 0x0C 0x1C 0x2C 0x3C 0x4C 0x5C 0x6C 0x7C 1101 0x0D 0x0D 0x1D 0x2D 0x3D 0x4D 0x5D 0x6D 0x7D 1110 0x0E 0x0E 0x1E 0x2E 0x3E 0x4E 0x5E 0x6E 0x7E 1111 0x0F 0x0F 0...

Page 39: ...ll communication hubs except for the communication hub at the end of the bus which must have DIP switches 6 8 in ON position The RS 485 bus must be terminated on the EAC side EAC system A B A Termination enabled B A B A B Hub 1 DIP 6 OFF DIP 7 OFF DIP 8 OFF Hub 2 DIP 6 OFF DIP 7 OFF DIP 8 OFF Hub N End of Bus DIP 6 ON DIP 7 ON DIP 8 ON For a star connection set DIP 6 and 7 in ON position for one c...

Page 40: ... 485 bus should be made up of a twisted pair cable with characteristic impedance between 90 Ohm and 120 Ohm Maximum bus length is about 1000 m Depending on the EAC system a maximum of 32 units 31 communication hubs plus the EAC when using the DIP Switch for RS 485 addressing can be connected to the same bus Connect all RS485 A connectors together and all RS485 B connectors together depending on co...

Page 41: ... activate automatic pairing connect the two left pins PAIR with the jumper see figure Connect to supply voltage Connect the power and ground to the and the terminals of the connector marked 8V 24V Note Power supply input 8 24 VDC 3 5 W The power supply shall be a Limited Power Source LPS according to EN 60950 1 The power supply shall be 3 A over current protected Wire requirements 16 22 AWG Connec...

Page 42: ... can pair with up to 8 locks When pairing several locks to a communication hub the following addresses are used for the address range 1 15 Above this range only one lock can be paired DIP 4 DIP 1 AH30 Hub address Lock addresses 0000 Reserved 0001 0x01 0x01 0x11 0x21 0x31 0x41 0x51 0x61 0x71 0010 0x02 0x02 0x12 0x22 0x32 0x42 0x52 0x62 0x72 0011 0x03 0x03 0x13 0x23 0x33 0x43 0x53 0x63 0x73 0100 0x0...

Page 43: ... this mode are set consecutively For example if communication hub has address 1 the locks will get address 1 8 9 16 17 24 etc DIP 5 DIP 1 AH30 Hub address Lock addresses 0000 Reserved 0001 0x01 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0010 0x02 0x09 0x0A 0x0B 0x0C 0x0D 0x0E 0x0F 0x10 0011 0x03 0x11 0x12 0x13 0x14 0x14 0x16 0x17 0x18 0100 0x04 0x19 0x1A 0x1B 0x1C 0x1D 0x1E 0x1F 0x20 This mode is use...

Page 44: ...e of installation since all the lock addresses used are unique Addressing is simply made by selecting a unique address for each communication hub Mixed installation A mixed installation uses both AH15 and AH30 communication hubs with the address range from 1 to 63 according to this figure Lock 0x01 Lock 0x11 Lock 0x21 Lock 0x02 Lock 0x03 Lock 0x13 Lock 0x11 Lock 0x2F AH30 0x01 AH15 0x02 AH30 0x03 ...

Page 45: ... paired If so use the Programming Application to unpair any locks Upgrading firmware in AH30 communication hubs The latest firmware 2 6 0 or later for AH30 communication hubs adds the functionality to use DIP Switch addresses in the range of 16 31 DIP switch 5 Before upgrading make sure that your existing AH30 communication hubs do not have DIP 5 activated If DIP 5 is activated and the communicati...

Page 46: ...en three red flashes Aperio lock and EAC offline Yellow off fast flash UHF communication Some special LED indication schemes are used during lock maintenance actions Yellow green flashes Pairing active 2 sec AH40 Ethernet LED indication The LED on the AH40 communication hub indicates both the status of the Ethernet link level and ethernet communication 2 sec Green Green off fast flash Ethernet lin...

Page 47: ... Three red flashes 5 second each Lock mechanism is blocked when closing Tamper Ten red flashes 125 sec each Repeated every 10 sec Time to replace the battery Error in lock maintenance required Ten red flashes 125 sec each Repeated every 10 sec if lock cannot close 2 1 Battery reached end of life lock disabled Card access configurable Card PIN access configurable EAC response time Enter PIN One yel...

Page 48: ......

Page 49: ......

Page 50: ......

Page 51: ......

Page 52: ...ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience Wireless lock technology Contact www assaabloy com aperio ...

Reviews: