56
EN
Configuration
Example configuration
The following procedure serves as an example of how you can use the key switch
to set and save the pre-alarm time at twenty seconds.
Starting configuration mode
1 Open the cover on the escape door module and leave it open.
2 Push the key to the left:
3 Turn the key to the left and hold it for 5 seconds.
Changing to the “Pre-alarm time” menu.
1 Turn the key 4 times to the left.
You are now in the ‘Pre-alarm time’ configuration menu. This is displayed by
the left-hand yellow LED lighting up.
Configuring pre-alarm time
1 Now turn the key to the right and hold it for the duration of the desired
pre-alarm time (20 seconds).
The green LEDs blink alternately in clockwise motion, with each cycle
corresponding to one second.
The change you have made will be saved as soon as you let go of the key.
Leaving the configuration menu
1 Press the key to the left until the 4 yellow LEDs flash.
2 Push the key to the right:
The 4 green LEDs flash alternately in pairs in a diagonal sequence and the
lower yellow LED lights up.
3 Close the cover again.
The device has been configured and is ready to operate.