Alignment of the rosette
Two pictograms – fail-unlocked and fail-locked – are printed on the rosette
(see ill. 2). The rosette must be aligned accordingly so that during operation
the pictogram “fail-locked” and during installation the pictogram “fail-unlocked”
points to the mark of the locking element.
Mounting
Mounting and adjustment only when the rosette is set to “fail-unlocked
Otherwise, it would not be possible to open the door or the drawer any
more after having been closed.
Four each cylindrically countersunk mounting holes each are provided for
mounting the locking element as well as the rosette. Position of mounting
holes see drawing. Reducing bushes, screws and washers are included in the
mounting material supplied.
Before fastening the two washers of special steel with screws, they must
be placed into the elongated holes of the locking element.
Dimensioned instructions
!
Illustration 2: Alignment of the rosette
Illustration 3: Dimensioned drawing
18.5
cylindrical countersinking
depth 2.5
dimensions in mm
or
Mark
fail-unlocked operation
position during mounting
fail-locked operation
position during operation
locking element
rosette