background image

4

5

English

ClearCMOS

1 (header)

NMI Button

SGPIO

2

Front Panel

1

Buzzer

1

NVME support

WC422D8A-2T/U: 

4 Oculink (from CPU) 

WC422D8A-2T:

2 Oculink (from CPU)

80 Debug Port 
LED

1

Speaker

1

VROC

1

PWR_SMB

OH/FanFail 
LED

1 (Fan Fail LED only )

System BIOS
BIOS Type

128Mb AMI UEFI Legal BIOS

BIOS Features

- Plug and Play (PnP) 
- ACPI 2.0 Compliance Wake Up Events 
- SMBIOS 2.8.0 Support 
- ASRock Rack Instant Flash

Hardware Monitor
Temperature

-CPU Temperature Sensing 
-System Temperature Sensing 
-Card side Temperature Sensing 
-System TR Temperature Sensing

Fan

- CPU/Front Fan Tachometer 
- CPU Quiet Fan (Allow CPU Fan Speed Auto-Adjust by CPU 
Temperature) 
- CPU/Front Fan Multi-Speed Control

Voltage

Voltage Monitoring: Vcore, VCCSA, VCCIO, VCCMAB, 
VCCMCD, 3v, 5v, 12v, 1.05V_PCH, 1.05V_PCH_PHY, +BAT, 
3VSB, 5VSB, 5V_Dual, 5V_Dual2

Support OS
OS

Microsoft® Windows® 
- Windows 10 (64 bit)

Linux® 
- RedHat Enterprise Linux Server 6.9 (64 bit) / 7.3 (64 bit) /  
   7.6 (64 bit) 
- SUSE Enterprise Linux Server 11 SP4 (64 bit) / 12 SP2 (64 bit) /  
   12 SP4 (64 bit) 
- Ubuntu 16.04 (64 bit) / 16.10 (64 bit)

Summary of Contents for WC422D8A-2T

Page 1: ...WC422D8A 2T WC422D8A 2T U User Manual Version 1 0 Published November 2019 Copyright 2019 ASRock Rack INC All rights reserved...

Page 2: ...implied including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose In no event shall ASRock Rack its directors officers employees or agen...

Page 3: ...ant to know more about ASRock Rack you re welcome to visit ASRock Rack s website at www ASRockRack com or you may contact your dealer for further information ASRock Rack Incorporation 6F No 37 Sec 2 J...

Page 4: ...2 2 Pre installation Precautions 16 2 3 Installing the CPU 17 2 4 Installing the CPU Fan and Heatsink 20 2 5 Installation of Memory Modules DIMM 21 2 6 Expansion Slots PCI Express Slots 23 2 7 Jumper...

Page 5: ...uration 55 3 3 4 Storage Configuration 58 3 3 5 Super IO Configuration 60 3 3 6 Serial Port Console Redirection 61 3 3 7 H W Monitor 64 3 3 8 Runtime Error Logging 66 3 3 9 Intel ME Configuration 68 3...

Page 6: ...System 87 4 2 Support CD Information 87 4 2 1 Running The Support CD 87 4 2 2 Drivers Menu 87 4 2 3 Utilities Menu 87 4 2 4 Contact Information 87 Chapter 5 Troubleshooting 88 5 1 Troubleshooting Pro...

Page 7: ...2T U Motherboard ATX Form Factor 12 0 in x 9 6 in 30 5 cm x 24 4 cm Support CD Quick Installation Guide 1 x I O Shield 1 x SATA3 Cable 60cm 2 x Screws for M 2 Sockets If any items are missing or appea...

Page 8: ...GB 64GB DIMM Frequency R DIMM 2666 2400 2133 1866 1600MHz LR DIMM 2666 2400 2133 1866 1600MHz Voltage 1 2V Expansion Slot PCIe 3 0 x16 Slot4 Gen3 x16 link auto switch to x8 link if Slot3 is occupied S...

Page 9: ...Audio Audio Codec Realtek ALC892 Rear Panel I O PS 2 KB mouse 1 VGA Port 1 x D Sub USB 3 0 Port 4 USB 3 1 Port 2 1 type A 1 type C LAN Port 2 x RJ45 Gigabit Ethernet LAN ports 1 x RJ45 Dedicated IPMI...

Page 10: ...nitor Temperature CPU Temperature Sensing System Temperature Sensing Card side Temperature Sensing System TR Temperature Sensing Fan CPU Front Fan Tachometer CPU Quiet Fan Allow CPU Fan Speed Auto Adj...

Page 11: ...FireX Technology NOTE Please refer to our website for the latest specifications This motherboard supports Wake from on Board LAN To use this function please make sure that the Wake on Magic Packet fro...

Page 12: ...ty you can press the F6 key during the POST or the F2 key to enter into the BIOS setup menu to access ASRock Rack Instant Flash Just launch this tool and save the new BIOS file to your USB flash drive...

Page 13: ...1 T USB31_TA_1 B USB31_TC_1 PS2 Keyboard Mouse LAN2 CHASSIS_ID0 1 1 1 BATTERY CHASSIS_ID1 CHASSIS_ID2 PECI1 FRNT_FAN1 FRNT_FAN2 FRNT_FAN3 FRNT_FAN4 DDR4_A2 64 bit 288 pin module White DDR4_A1 64 bit...

Page 14: ...Connector FRNT_FAN4 15 2 x 288 pin DDR4 DIMM Slots DDR4_A1 DDR4_B1 Blue 16 2 x 288 pin DDR4 DIMM Slots DDR4_A2 DDR4_B2 White 17 ATX 12V Power Connector ATX12V1 18 PWM Configuration Header PWM_CFG1 19...

Page 15: ...io Header HD_AUDIO1 48 OCULink x4 Connector OCU1 49 M 2 Socket M2_2 Type 2230 2242 2260 2280 22110 50 OCULink x4 Connector OCU2 51 CPU Fan Connector CPU1_FAN1 52 Front VGA Header FRNT_VGA1 For DIMM in...

Page 16: ...PS2 Keyboard Mouse LAN2 CHASSIS_ID0 1 1 1 BATTERY CHASSIS_ID1 CHASSIS_ID2 PECI1 FRNT_FAN1 FRNT_FAN2 FRNT_FAN3 FRNT_FAN4 DDR4_A2 64 bit 288 pin module White DDR4_A1 64 bit 288 pin module Blue CPU1_FAN1...

Page 17: ...14 Front Fan Connector FRNT_FAN4 15 2 x 288 pin DDR4 DIMM Slots DDR4_A1 DDR4_B1 Blue 16 2 x 288 pin DDR4 DIMM Slots DDR4_A2 DDR4_B2 White 17 ATX 12V Power Connector ATX12V1 18 PWM Configuration Heade...

Page 18: ...r OCU1 49 OCULink x4 Connector OCU3 50 OCULink x4 Connector OCU4 51 M 2 Socket M2_2 Type 2230 2242 2260 2280 22110 52 OCULink x4 Connector OCU2 53 CPU Fan Connector CPU1_FAN1 54 Front VGA Header FRNT_...

Page 19: ...1 1 1 1 1 1 1 1 2 3 4 5 7 8 1 1 1 DDR4_A 64 bit 288 pin module Blue DDR4_B 64 bit 288 pin module Blue DDR4_A 64 bit 288 pin module Blue DDR4_B 64 bit 288 pin module Blue DDR4_A 64 bit 288 pin module...

Page 20: ...heartbeat LED 2 FFAN_LED1 Amber FRNT_FAN1 failed 3 FFAN_LED2 Amber FRNT_FAN2 failed 4 FFAN_LED3 Amber FRNT_FAN3 failed 5 FFAN_LED4 Amber FRNT_FAN4 failed 6 CPU_FAN_LED1 Amber CPU1_FAN1 failed 7 FFAN_...

Page 21: ...B 3 1 Type A Port USB31_TA_1 15 10G LAN RJ 45 Port LAN2 8 USB 3 1 Type C Port USB31_TC_1 16 10G LAN RJ 45 Port LAN1 LAN Port LED Indications There are two LED next to the LAN port Please refer to the...

Page 22: ...connection or no link Blinking Orange Data Activity Amber 1Gbps connection On Link Green 10Gbps connection If you use a 2 channel speaker please connect the speaker s plug into Front Speaker Jack See...

Page 23: ...WC422D8A 2T WC422D8A 2T U 17 English 1 7 Block Diagram...

Page 24: ...to secure the motherboard to the chassis Attention Before installing this motherboard be sure to unscrew and remove the standoff at the marked location under the motherboard from the chassis in order...

Page 25: ...lso remember to use a grounded wrist strap or touch a safety grounded object before you handle the compo nents 3 Hold components by the edges and do not touch the ICs 4 Whenever you uninstall any comp...

Page 26: ...ocket 1 Before you insert the 2066 Pin CPU into the socket please check if the PnP cap is on the socket if the CPU surface is unclean or if there are any bent pins in the socket Do not force to insert...

Page 27: ...WC422D8A 2T WC422D8A 2T U 21 English 4 A 3 B 5...

Page 28: ...22 English Please save and replace the cover if the processor is removed The cover must be placed if you wish to return the motherboard for after service 6 A B 8 B 7 A...

Page 29: ...WC422D8A 2T WC422D8A 2T U 23 English 2 4 Installing the CPU Fan and Heatsink 1...

Page 30: ...ted Populated Since installing three memory modules is NOT supported on this motherboard we suggest not using this configuration 1 It is not allowed to install a DDR DDR2 or DDR3 memory module into a...

Page 31: ...8A 2T WC422D8A 2T U 25 English 1 2 3 The DIMM only fits in one correct orientation It will cause permanent damage to the motherboard and the DIMM if you force the DIMM into the slot at incorrect orien...

Page 32: ...x8 x8 CPU 1 PCI Express Slot Configuration PCIE 5 PCIE 6 Single PCIE Card x0 x16 Two PCIE Cards x8 x8 PCIE 3 PCIE 4 Single PCIE Card x0 x16 Two PCIE Cards x8 x8 Installing an expansion card Step 1 Be...

Page 33: ...you just finish updating the BIOS you must boot up the system first and then shut it down before you do the clear CMOS action Please be noted that the password date time and user default profile will...

Page 34: ...ASSIS_ID0 Chassis ID1 Jumper 3 pin CHASSIS_ID1 Chassis ID2 Jumper 3 pin CHASSIS_ID2 Reserved for system level use Reserved for system level use Chassis ID0 Jumper 3 pin CHASSIS_ID0 Chassis ID1 Jumper...

Page 35: ...WC422D8A 2T WC422D8A 2T U 29 English Enable Disable BMC Jumper 2 pin MFG_N Normal Mode Default BMC Enabled BMC Disabled...

Page 36: ...PLED System Power LED Connect to the power status indicator on the chassis front panel The LED is on when the system is operating The LED is off when the system is in S4 sleep state or powered off S5...

Page 37: ...D These two 2 pin headers allow you to use the Gigabit internet indicator cable to connect to the LAN status indicator When this indicator flickers it means that the internet is prop erly connected C...

Page 38: ...By default USB3_7 supports a USB 2 0 device and both M_SATA_0 and M_SATA_1 are enabled To enable USB3_7 to support a USB 3 0 device please go to the BIOS Settings BIOS Menu Advanced USB Configuration...

Page 39: ...B Configuration USB3_7 Select If USB3_7 supports a USB 3 0 device M_SATA_0 and M_SATA_1 are disabled USB 3 0 Header 19 pin USB3_5_6 Besides four default USB 3 0 ports on the I O panel there is one USB...

Page 40: ...activate the front mic go to the FrontMic Tab in the Realtek Control panel and adjust Recording Volume Front Panel Audio Header 9 pin HD_AUDIO1 J_SENSE OUT2_L 1 MIC_RET PRESENCE GND OUT2_R MIC2_R MIC2...

Page 41: ...12V 3V 12 1 13 24 3V 12V GND PSON GND GND GND 5V 5V 5V GND N A This motherboard provides a 24 pin ATX power connector To use a 20 pin ATX power supply please plug it along Pin 1 and Pin 13 ATX 12V Pow...

Page 42: ...OCK GND GND SDATAOUT0 for 7 pin SATA_SGPIO1 SDATAOUT1 for 7 pin SATA_SGPIO2 This header supports Serial Link interface for onboard SATA connections PSU SMBus Header PSU_SMB1 3V 1 GND ALERT SMBCLK SMBD...

Page 43: ...R1 TR1 GND Please connect the thermal sensor cable to either pin 1 2 or pin 2 3 and the other end to the device which you wish to monitor its temperature PWM Configuration Header 3 pin PWM_CFG1 1 GND...

Page 44: ...f operation SKU HW key required Key features Pass thru Not needed Pass thru only no RAID LED Management Hot Plug Support RAID 0 support for Intel Fultondale NVMe SSDs Standard VROCSTANMOD Pass thru SK...

Page 45: ...A12 CLK_OCU_1 B12 OCU _PERST_BUF_N A13 CLK_OCU_1 B13 OCU _B13_PRSNT_N A14 GND B14 GND A15 OCU _RX_DP2 B15 OCU_TX_DP2 A16 OCU _RX_DN2 B16 OCU_TX_DN2 A17 GND B17 GND A18 OCU _RX_DP3 B18 OCU_TX_DP3 A19...

Page 46: ...s Code Description 0x10 PEI_CORE_STARTED 0x11 PEI_CAR_CPU_INIT 0x15 PEI_CAR_NB_INIT 0x19 PEI_CAR_SB_INIT 0x31 PEI_MEMORY_INSTALLED 0x32 PEI_CPU_INIT 0x33 PEI_CPU_CACHE_INIT 0x34 PEI_CPU_AP_INIT 0x35 P...

Page 47: ...NIT 0x71 DXE_SB_SMM_INIT 0x72 DXE_SB_DEVICES_INIT 0x78 DXE_ACPI_INIT 0x79 DXE_CSM_INIT 0x90 DXE_BDS_STARTED 0x91 DXE_BDS_CONNECT_DRIVERS 0x92 DXE_PCI_BUS_BEGIN 0x93 DXE_PCI_BUS_HPC_INIT 0x94 DXE_PCI_B...

Page 48: ...USB_ENABLE 0xA0 DXE_IDE_BEGIN 0xA1 DXE_IDE_RESET 0xA2 DXE_IDE_DETECT 0xA3 DXE_IDE_ENABLE 0xA4 DXE_SCSI_BEGIN 0xA5 DXE_SCSI_RESET 0xA6 DXE_SCSI_DETECT 0xA7 DXE_SCSI_ENABLE 0xA8 DXE_SETUP_VERIFYING_PASS...

Page 49: ...E_LEGACY_OPROM_INIT 0xB3 DXE_RESET_SYSTEM 0xB4 DXE_USB_HOTPLUG 0xB5 DXE_PCI_BUS_HOTPLUG 0xB6 DXE_NVRAM_CLEANUP 0xB7 DXE_CONFIGURATION_RESET 0xF0 PEI_RECOVERY_AUTO 0xF1 PEI_RECOVERY_USER 0xF2 PEI_RECOV...

Page 50: ...x57 PEI_CPU_MISMATCH 0x58 PEI_CPU_SELF_TEST_FAILED 0x59 PEI_CPU_NO_MICROCODE 0x5A PEI_CPU_ERROR 0x5B PEI_RESET_NOT_AVAILABLE 0xD0 DXE_CPU_ERROR 0xD1 DXE_NB_ERROR 0xD2 DXE_SB_ERROR 0xD3 DXE_ARCH_PROTOC...

Page 51: ...ID_PASSWORD 0xD9 DXE_BOOT_OPTION_LOAD_ERROR 0xDA DXE_BOOT_OPTION_FAILED 0xDB DXE_FLASH_UPDATE_FAILED 0xDC DXE_RESET_NOT_AVAILABLE 0xE8 PEI_MEMORY_S3_RESUME_FAILED 0xE9 PEI_S3_RESUME_PPI_NOT_FOUND 0xEA...

Page 52: ...ront rear UID blue LED indicator will be turned on Press the UID button again to turn off the indicator 2 11 Driver Installation Guide To install the drivers to your system please insert the support C...

Page 53: ...ry adapter handles all non TCP IP traffic The Secondary adapter will receive fallback traffic if the primary fails If the Preferred Primary adapter fails but is later restored to an active status cont...

Page 54: ...PCI Express module up to Gen3 x4 16 Gb s If M2_1 is occupied by a SATA type M 2 device SATA_7 will be disabled Installing the M 2_SSD NGFF Module Step 1 Prepare a M 2_SSD NGFF module and the screw 3...

Page 55: ...o Step 5 if you are going to use the default nut Otherwise release the standoff by hand B C D E A Step 4 Peel off the yellow protective film on the nut to be used Hand tighten the standoff into the de...

Page 56: ...50 English NUT1 NUT2 D E Step 6 Tighten the screw with a screwdriver to secure the module into place Please do not overtighten the screw as this might damage the module...

Page 57: ...as a menu bar with the following selections Item Description Main To set up the system time date information Advanced To set up the advanced UEFI features Security To set up the security features Boot...

Page 58: ...selected items Tab Switch to next function Enter To bring up the selected screen PGUP Go to the previous page PGDN Go to the next page HOME Go to the top of the screen END Go to the bottom of the scr...

Page 59: ...ain screen will appear and display the system overview The Main screen provides system overview information and allows you to set the system time and date All screenshots in this document are provided...

Page 60: ...section you may set the configurations for the following items CPU Configuration Memory Configuration Chipset Configuration Storage Configuration Super IO Configu ration Serial Port Console Redirectio...

Page 61: ...reduce CPU voltage and lead to system stability or compatibility issues with some power supplies Please set this item to Disabled if above issues occur Intel Turbo Boost Technology Intel Turbo Boost T...

Page 62: ...le CPU internal thermal control mechanisms to keep the CPU from overheating No Execute Memory Protection Processors with No Execution Memory Protection Technology may prevent certain classes of malici...

Page 63: ...able Disables this feature Auto Sets it to the MRC default setting current default is Enable DRAM Frequency If Auto is selected the motherboard will detect the memory module s inserted and assign the...

Page 64: ...nce Primary Graphics Adapter If PCI Express graphics card is installed on the motherboard you may use this option to select PCI Express or Onboard VGA as the primary graphics adapter If no PCI Express...

Page 65: ...allows you to select PCIE1 Link Width The default value is Auto PCIE1 Link Speed This allows you to select PCIE1 Link Speed The default value is Auto PCIE1 ASPM Support This option enables or disables...

Page 66: ...em to set front panel HD audio to Auto or Disabled PS2 Y Cable Enable the PS2 Y Cable or set this option to Auto Restore AC Power Loss Select the power state after a power failure If Power Off is sele...

Page 67: ...Aggressive Link Power Management Use this item to enable or disable SALP Hard Disk S M A R T Use this item to enable or disable the S M A R T Self Monitoring Analysis and Reporting Technology feature...

Page 68: ...will minimize your boot time and get the best performance If you still want to boot from Marvell SATA3 controller please set this item to Yes Easy RAID Installer Easy RAID Installer helps you to copy...

Page 69: ...ort 1 COM1 Serial Port Use this item to enable or disable the serial port Change Settings Use this item to select an optimal setting for Super IO device SOL Configuration Use this item to set paramete...

Page 70: ...ure Console Redirection Settings and specify how your computer and the host computer to which you are connected exchange information Terminal Type Use this item to select the preferred terminal emulat...

Page 71: ...t signal can be sent to restart the flow Hardware flow uses two wires to send start stop signals The options include None and Hardware RTS CTS VT UTF8 Combo Key Support Use this item to enable or disa...

Page 72: ...Type Use this item to select the preferred terminal emulation type for out of band management It is recommended to select VT UTF8 Option Description VT100 ASCII character set VT100 Extended VT100 tha...

Page 73: ...ed will controlled by BMC If Manual is selected configure the items below CPU1_FAN1 This allows you to set the CPU fan1 s speed The default value is Smart Fan FRNT_FAN1 This allows you to set the fron...

Page 74: ...rt fan s level speed Smart Fan Duty Control Smart Fan Duty x x means 1 to 11 stage This allows you to set duty cycle for each stage Smart Fan Temp Control Smart Fan Temp x x means 1 to 11 stage This a...

Page 75: ...r log features S W Error Injection Support When it is set to Enabled S W Error Injection is supported by unlocking MSR Ox790 Memory Error Memory enabling and logging setup option Correctable Error Thr...

Page 76: ...70 English PCIE Uncorrected Error Enable Use this item to enable or disable PCIe Uncorrectable errors PCIE Fatal Error Enable Use this item to enable or disable PCIe Ftal errors...

Page 77: ...WC422D8A 2T WC422D8A 2T U 71 English 3 3 9 Intel ME Configuration Intel ME Configuration screen displays the Intel ME Configuration information such as Operational Firmware Version and Firmware State...

Page 78: ...e system to be waked up by onboard COM port modem Ring In signals RTC Alarm Power On Allow the system to be waked up by the real time clock alarm Set it to By OS to let it be handled by your operating...

Page 79: ...y issues it is recommended to disable legacy USB support Select UEFI Setup Only to support USB devices under the UEFI setup and Windows Linux operating systems only PS 2 Simulator Enable PS 2 Simulato...

Page 80: ...isk or hard drive and launch this tool then you can update your UEFI only in a few clicks without preparing an additional floppy diskette or other compli cated flash utility Please be noted that the U...

Page 81: ...Leave it blank and press enter to remove the password User Password Set or change the password for the user account Users are unable to change the settings in the UEFI Setup Utility Leave it blank an...

Page 82: ...re Boot keys Force System to Setup Mode clear all Secure Boot Variables Change takes effect after reboot Install Default Secure Boot Keys Please install default secure boot keys if it s the first time...

Page 83: ...he first time you use secure boot Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 hash of the binary into Authorized Signature Database db Export Secure Boot Variables Copy N...

Page 84: ...RT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test Authorized Signatures Enroll Factory Defaults or load certifica...

Page 85: ...a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Sourc...

Page 86: ...oot From Onboard LAN Use this item to enable or disable the Boot From Onboard LAN feature Setup Prompt Timeout Configure the number of seconds to wait for the UEFI setup utility Bootup Num Lock If thi...

Page 87: ...cy only to run those that support legacy option ROM only Select Do not launch to not execute both legacy and UEFI option ROM PCIE5 PCIE6 Slot OpROM To select Slot Storage and Network Option ROM policy...

Page 88: ...pROM To select Slot Storage and Network Option ROM policy In Auto option the default is Dis abled with NVMe device but it is Legacy with other devices This item can t select Video Option ROM policy M2...

Page 89: ...r specified time out In PILOTII BMC starts at the same time when BIOS starts during AC power ON It takes around 30 seconds to initialize Host to BMC interfaces Inventory support Use this item to execu...

Page 90: ...res of System Event Logging during boot Erase SEL Use this to choose options for earsing SEL When SEL is Full Use this to choose options for reactions to a full SEL Log EFI Status Codes Use this item...

Page 91: ...is assigned by DHCP If you prefer using a static IP address toggle to Yes and the changes take effect after the system reboots The default value is No Configuration Address Source Select to configure...

Page 92: ...ow to set up remote control environment and use the IPMI man agement platform please refer to the IPMI Configuration User Guide or go to the Support website at http www asrockrack com support faq asp...

Page 93: ...t and Yes Every reset If Yes is selected all logged events will be erased When Log is Full Use this item to choose options for reactions to a full Smbios Event Log The options include Do Nothing and E...

Page 94: ...es changed here do not take effect until computer is restarted entries which utilize a multiple event counter The value ranges from 0 to 99 minutes View Smbios Event Log Press Enter to view the Smbios...

Page 95: ...following message Discard changes and exit setup will pop out Press ESC key or select Yes to exit the UEFI SETUP UTILITY without saving any changes Discard Changes When you select this option the foll...

Page 96: ...g The Support CD To begin using the support CD insert the CD into your CD ROM drive The CD automatically displays the Main Menu if AUTORUN is enabled in your computer If the Main Menu does not appear...

Page 97: ...re set to default settings 3 Check the settings of the 115V 230V switch on the power supply 4 Verify if the battery on the motherboard provides 3VDC Install a new battery if it does not If there is no...

Page 98: ...battery on the motherboard provides 3VDC Install a new battery if it does not 2 Confirm whether your power supply provides adaquate and stable power Other problems 1 Try searching keywords related to...

Page 99: ...t or a copy of your invoice marked with the date of purchase is required By calling your vendor or going to our RMA website http event asrockrack com tsd asp you may obtain a Returned Merchandise Auth...

Reviews: