Installation Instructions – ASPEN 1900 Series Mid-Sized Bollard
Installation Instructions – ASPEN 1900 Series Mid-Sized Bollard
ADL141353 www.eaton.com
Figure 7.
Figure 8.
3X Screws 120°
Apart
1. Disconnect or turn fixture power OFF prior to
performing all maintenance activities.
2. Remove external sleeve from base by removing three
screws and placing in a safe location (Figure 8).
3. ATTENTION: Do not try to unscrew optical
assembly to access lamp. Tampering with optical
assembly will void fixture warranty.
4. Cat. 1900-OA (MR16): Align and insert the two pins
at the bottom of the lamp with the two in GU5.3
socket. Make sure base of lamp touches the base
of the socket. Do not rotate lamp when installing or
removing from socket.
5. Cat. 1900-OA (PAR20): Thread lamp clockwise into
socket until firmly seated. This fixture only accepts
PAR20, 50W max incandescent lamps.
6. Cat. 1900-OA (LED): See LED Module Section (Figure
9).
7. Cat. 1900-IL (Compact Fluorescent Lamp): Align pins
with socket. Place the lamp in the socket and turn
clockwise to snap lamp into place. This fixture accepts
either 26W, 32W or 42W compact flourescent lamps.
8. Place external sleeve over component frame assembly
and secure to base using the three counter-sink
screws.
Step 6: Relamping
Remove external
sleeve to access
lamp or LED
Figure 9.
1. Push button enables switching between four light
output modes (100%, 80%, 55% and 18%). Module
is factory set to 100%.
2. The selected setting is stored in memory. The device
automatically switches to selected mode after power
has been interrupted. If the module is connected to a
dimmer, the push button is automatically de-activated
and the dimmer will be the sole control method of the
light output.
REVIEW: LED Module
Push Button
Location
DO NOT REMOVE
OPTICAL ASSEMBLY
TO ACCESS LAMP.
THIS IS FACTORY
SEALED.
Optical Assembly
B.C. 2.10
1.0
.57
.33
3.0
.50
Reference: Anchor Bolt Pad Plate Template
1. Template is not to scale and to be used as a reference
only (Figure 10).
Figure 10.
Shown in inches