WARNING

Make certain power is OFF before starting installation 

or attempting any maintenance.

WARNING

Risk of fire/electric shock. If not qualified, consult an 

electrician. This equipment to be installed by trained 

and qualified personel.

WARNING

Risk of Electric Shock - Disconnect power at fuse or 

circuit breaker before installing or servicing.

WARNING

Risk of Burn - Disconnect power and allow fixture to cool 

before servicing.

WARNING

Risk of Personal Injury - Fixture may become damaged 

and/or unstable if not installed properly.

WARNING

Risk of Burn - Disconnect power and allow fixture to cool 

before servicing.

NOTE:

 These instructions do not claim to cover all details 

or variations in the equipment, proocedure, or 

process described, nor to provided directions for 

meeting every possible contingency during instal-

lation, operation or maintenance. When additional 

information is desired to satisfy a problem not cov-

ered sufficiently for user’s purpose, please contact 

your nearest representative.

NOTE:

 Care must be taken not to set lighting fixture down 

on optical lenses or lift fixture in lens area.

NOTE:

 To prevent wiring damage or abrasion, do not 

expose wiring to edges of sheet metal or any 

sharp objects. Proper grounding is required to 

ensure personal safety.

NOTE:

 Specifications and dimensions subject to change 

without notice.

NOTE:

 Replace removable parts after servicing.

I

MPORTANT:

 Read carefully before installing fixture. Retain for future reference.

GENERAL:

 Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the

attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the

housing to assure you have received the correct material.

SAFETY:

 This fixture must be wired in accordance with the National Electrical Code and applicable local codes and

ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under

installation section.

APPLICATIONS: 

This lighting fixture is designed for outdoor lighting services, and should not be used in area of limited

ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do not

expose lighting fixture to rain, dust or other environmental conditions prior to installation. Best results will be obtained if 

installed and maintained according to the following recommendations.

IMPORTANT LISTINGS AND CERTIFICATIONS SPECIFIC TO FIXTURE:

 

z

SUITABLE FOR WET LOCATIONS.

 

z

SUITABLE FOR GROUND MOUNT ONLY.

 

z

SUITABLE FOR OPERATION NOT EXCEEDING 40°C AMBIENT

Installation Instructions – ASPEN 1900 Series Mid-Sized Bollard

Summary of Contents for 1900-OA

Page 1: ...INS Brand Logo reversed out of black INS ADL141353 Installation Instructions ASPEN 1900 Series Mid Sized Bollard 1900 OA 1900 IL ...

Page 2: ... to edges of sheet metal or any sharp objects Proper grounding is required to ensure personal safety NOTE Specifications and dimensions subject to change without notice NOTE Replace removable parts after servicing IMPORTANT Read carefully before installing fixture Retain for future reference GENERAL Upon receipt of the fixture thoroughly inspect for any freight damage which should be brought to th...

Page 3: ...900 OA Series Mid Sized Bollards INSTALLATION Installation Instructions ASPEN 1900 Series Mid Sized Bollard ADL141353 www eaton com Mid Size Bollard External Sleeve with factory sealed optical assembly Component Frame Assembly Options Base Mounting Pad Anchor Bolt Assembly with Bolt Plate LED MR16 PAR20 Figure 2 ASPEN 1900 IL Series Mid Sized Bollards Mid Size Bollard External Sleeve with factory ...

Page 4: ...nd to allow 2 to protrude from the top of the base Figure 4 4 Pour concrete Make sure that pad plate is as level as possible Allow concrete to cure 2 Conduit Figure 4 Pad Plate on surface of concrete Figure 5 1 To level the base adjust the top three lock nuts 2 As you tighten the nuts the base compresses the underlying neoprene pad for quick and easy leveling Step 4 Leveling Base 1 Pull line volta...

Page 5: ...le Section Figure 9 7 Cat 1900 IL Compact Fluorescent Lamp Align pins with socket Place the lamp in the socket and turn clockwise to snap lamp into place This fixture accepts either 26W 32W or 42W compact flourescent lamps 8 Place external sleeve over component frame assembly and secure to base using the three counter sink screws Step 6 Relamping Remove external sleeve to access lamp or LED Figure...

Page 6: ...er Lighting Business 18001 East Colfax Avenue Aurora CO 80011 Cooperlighting com 2014 Eaton All Rights Reserved Printed in USA Imprimé aux États Unis Impreso en los EE UU Publication No ADL141353 Rev Date December 2014 Warranties and Limitation of Liability Please refer to www cooperlighting com WarrantyTerms for our terms and conditions Garanties et limitation de responsabilité Veuillez consulter...

Reviews: