ASM GmbH
MAN-PRAS-EX-E-13 5
www.asm-sensor.com
Mounting
POSIROT
®
EX
Instruction Manual
Mounting
Measuring error by misalignment of the position magnet
Placement and alignment of the position magnet
For non-contact sensor models air gap and alignment of sensor and position
magnet has to be observed. The linearity will degrade in case of misalign-
ment. Also external magnetic fields and magnetized materials nearby can
effect the measuring result.
Sensor
Position
magnet
Air gap
[mm]
Paral-
lelism
[°]
Error by axial misalignment
[°]
0,2
mm
0,5
mm
1 mm
2 mm
3 mm
4 mm
PRAS2EX
PRMAG2Z-EX
0 ... 9
5
0.1
0.2
0.6
1.5
4.5
8.5
PRMAG5Z-EX
0 ... 8
5
0.1
0.2
0.6
1.5
4.5
8.5
PRAS5EX
PRMAG2Z-EX
0 ... 5.5
5
0.1
0.2
0.6
1.5
4.5
8.5
PRMAG5Z-EX
0 ... 4.5
5
0.1
0.2
0.6
1.5
4.5
8.5