10 MAN-PRAS-EX-E-13
ASM GmbH
www.asm-sensor.com
POSIROT
®
EX
Instruction Manual
Mechanical
information for
PRMAG-EX
magnets
•
Secure mounting screws against loosening, use threadlocker if
necessary.
•
Mount sensor with corrosion-resistant screws.
•
Mount sensor on a flat and smooth metallic surface – this surface
must be connected to the local potential equalization.
•
Protect magnets against damage, the housings have been tested
with low impact energy 4J (DIN EN 61241-0).
•
Provide protection devices to avoid damage or blocking of sensor
and magnet by strange parts falling into the working area.
•
Contact between sensor and magnet is not allowed, an adequate
minimum clearance must be observed.
•
Dust concentrations between sensor and magnet are not allowed
– remove any dust deposit – appropriate maintenance intervals