VIPET - Hardware Installation and Maintenance Guide
U-0582-0512.doc – Issue: 05 complete, approved
Page 10 of 24
Status Monitor
power
processor
system fault
fault
VIPET
2U
VIPET-RS485-4
1U
VIPET
M6 PAN HEAD POZIDRIV SCREW
M6 PLAIN WASHER
M6 CAGE NUT
4.
If using the BOB04 or BOB08, install the unit and connect the unit as described in the VIPET-AUDIO-
4/8 & BOB04/08 Product Manual.
5.
Connect the wiring for control ports, signal monitoring, RS485, and RS232 cabling to the rear panel
connectors according to the application.
CONTROL PORT
EXP. 1
EXP. 2
VIPET
COM1
LPT1
VGA
ETH1
ETH0
USB2
USB4
USB1
USB3
RS232
(ASL-Router)
RS485
RS232
Keyboard
Mouse
Microphone
Audio Line-In
Audo Line-Out
Refer to VIPET-
AUDIO-4 /8 & BOB08
Product Manual
•
ETH0:
As standard, the VIPET uses Ethernet port ETH0.
•
EXP. 2:
As standard the RS232 interface type is enabled. This port can be disabled in order to enable
the RS485 (COM2/ttyS1) interface on the EXP. 1 port. The interface is enabled or disabled by
setting a link on the Watchdog Card (see Figure 4).
Summary of Contents for VIPET
Page 24: ......