Draught check
These accessories can be purchased from your
retailer.
Electrical installation
If the machine is delivered from the factory with
a plug attached, it can be connected to an earthed
wall socket. Otherwise, a permanent connection
using a multipolar circuit breaker must be made
by a qualified professional.
If this appliance is supplied from a cord extensions
set or electrical portable outlet device, the cord
extension ser or electrical portable outlet device
must be positioned so that it is not subject to
splashing or ingress of moisture.
Connection on delivery
The machine is supplied as 1-Phase, 230 V, 50
Hz, heat output 3000 W and has a 16 A plug. Any
residual current devices must be type A.
Coin operation
The machine is prepared for coin operation. Such
installation must be carried out by a qualified
professional.
The installation requires a connection cable to
power the coin meter. This connection cable can
be ordered using the factory spare part number
92 090 95.
The coin meter shall be able to short circuit two
signal lines for periods of up to 10 minutes. This
is to give the user time to load the machine,
choose a program and start the program after
putting the coins in.
'Insert coin' appears on the display when the
machine is started with the main power switch.
21
Installation