Overheating cutout

The machine incorporates a manually-resettable overheating cutout, operating
at a temperature of 150°C.

Thermostat

The thermostat has an automatic reset and the breaking temperature is of
115°C. It is used for indication of fluff in the filter or in the condenser. See fault
signals F4. Not all markets.

Capacitor

The drive motor capacitor is of 8µF.

Buzzer

A built-in buzzer is fitted so that the end of the program can be indicated audibly
if required.

Lighting

An interior drum light is fitted and is operated by the door switch.

Temperature sensing

Machine temperature is controlled by a thermistor for exact control. If the ther-
mistor is loose or gets a short circuit, the program is stopped. See fault signal
F3.

Moisture sensing

A  moisture sensor, measuring the humidity of the circulating air, controls the
drying process. The output from the sensor should be between 1-16 mV DC
when the machine is running. Other values from the sensor will stop the pro-
gram. See fault signal F5.

Interference suppression

The machine incorporates two RFI suppressors.

Starting relay

A relay mounted on the electrical components platform interrupts the power a) if
the machine overheats, b) if the door is opened or c) at the end of a program.

Mains cable

The mains cable is an RKK 3x1,5 or 5x1,5 mm

2

, with variants for different

markets.

Maximum operating time

In order to prevent the dryer from operating indefinitely (for whatever reason),
the maximum running time is 180 minutes, after which the program is
interrupted.See fault signal F2.

Summary of Contents for TD70

Page 1: ...INDEX TD70 TD73 TD76 TD77 DRYERS...

Page 2: ...Content Page Tumble dryers TD70A 1 2 TD73A 3 7 TD76A 8 9 TD77A 10 14...

Page 3: ...omatic programs can be started in setting 1 or 2 Setting 2 is more used and gives drying to selected temperature after which the program continues for about 14 minutes without any heat Setting 1 start...

Page 4: ...otor is a bi polar unit with direct coupling fan and gear facility for driving the drum Capacitor The capacitor is 8 uF mounted on the component bridge Heating element The heating element with 1900 95...

Page 5: ...The keyboard includes pushbuttons and indicators Main On Off switch The main On Off switch is fitted in the centre of the lower edge of the panel is a 2 pole switch and disconnects the phase and the z...

Page 6: ...or gets a short circuit the program is stopped See fault signal F3 Moisture sensing A moisture sensor measuring the humidity of the circulating air controls the drying process The output from the sens...

Page 7: ...eriod S1 5 Timed program One press on S1 5 means 5 min drying time cool down till the air temperature is 40 C or maximum 15 minutes Continued pressings increases the drying time to 10 15 20 30 50 60 7...

Page 8: ...During the heating up the moisture in the machine is indicated by D1 and D2 normally 3 13 D3 and D4 indicate the temperature Fault signals The following codes are indicated by D3 and D4 F2 Maximal dry...

Page 9: ...ing suppIy fuses blown Fuse L1 blown Machine will stop after ca 20 minutes Heater power will be reduced 720W Fuse L2 blown The machine will not start Main power On light extinguished Fuse L3 blown Mac...

Page 10: ...can set this sequence directly and to get an airing program The program unit The program unit has a mecanically marked setting points motor with 4 min stages and built in buzzer Pushbuttons The pushbu...

Page 11: ...heating and when the door is opened Door contact The door contact is activated by the door and breaks the operating circuit Condensate water pump There is a pump in the machine to pump water from the...

Page 12: ...ch The main On Off switch is fitted in the centre of the lower edge of the panel is a 2 pole switch and disconnects the phase and the zero line Indicating lamp The indicating lamp shows that the main...

Page 13: ...Temperature sensing Machine temperature is controlled by a thermistor for exact control If the ther mistor is loose or gets a short circuit the program is stopped See fault signal F3 Moisture sensing...

Page 14: ...eriod S1 5 Timed program One press on S1 5 means 5 min drying time cool down till the air temperature is 35 C or maximum 15 minutes Continued pressings increases the drying time to 10 15 20 30 50 60 7...

Page 15: ...are shut off During the heating up the moisture in the machine is indicated by D1 and D2 normally 3 13 D3 and D4 indicate the temperature Fault signals The following codes are indicated by D3 and D4 F...

Page 16: ...ing suppIy fuses blown Fuse L1 blown Machine will stop after ca 20 minutes Heater power will be reduced 950W Fuse L2 blown The machine will not start Main power On light extinguished Fuse L3 blown Mac...