background image

TD 73

ELECTRICAL FEATURES TD 73A

General design

TD 73A is a vented dryer, which incorporate a microprocessor for process control,
and pushbutton selection of programs. The pushbutton panel also carries LEDs
and two-digit 7-segments displays which indicate selected time (for times
programs), time-delayed starts etc.

Electrical supply

The machines are supplied as 3-phase, 230V, 10A, heater power 2620W. They
can also be reconnected internally to suit them for a single-phase, heater power
2620W, 16A or single-phase. Heater power 1900W, 10A.

Programcontrol

Control unit

The control unit has a microprocessor for control of the motor, heater, program etc.

Keyboard

The keyboard includes pushbuttons and indicators.

Main On/Off switch

The main On/Off switch is fitted in the centre of the lower edge of the panel, is a 2-
pole switch and disconnects the phase and the zero-line.

Indicating lamp

The indicating lamp shows that the main switch is turned on.

Door switch

The door operates a door-switch that, when open, interrups the program. If the
door has been opened while the machine is running, and then closed again, the
machine must be restarted by the Start pushbutton.

Drive motor

The main drive motor is at the bottom of the machine, driving the drum and the two
fans that circulate internal air and external air.

Heater

TD 73 A: The maximum heating power is 2620W provided by two heaters with
ratings of 1900W and 720W  respectively, so that the machine can be recon-
nected to provide a reduced heating power of 1900W.

Summary of Contents for TD70

Page 1: ...INDEX TD70 TD73 TD76 TD77 DRYERS...

Page 2: ...Content Page Tumble dryers TD70A 1 2 TD73A 3 7 TD76A 8 9 TD77A 10 14...

Page 3: ...omatic programs can be started in setting 1 or 2 Setting 2 is more used and gives drying to selected temperature after which the program continues for about 14 minutes without any heat Setting 1 start...

Page 4: ...otor is a bi polar unit with direct coupling fan and gear facility for driving the drum Capacitor The capacitor is 8 uF mounted on the component bridge Heating element The heating element with 1900 95...

Page 5: ...The keyboard includes pushbuttons and indicators Main On Off switch The main On Off switch is fitted in the centre of the lower edge of the panel is a 2 pole switch and disconnects the phase and the z...

Page 6: ...or gets a short circuit the program is stopped See fault signal F3 Moisture sensing A moisture sensor measuring the humidity of the circulating air controls the drying process The output from the sens...

Page 7: ...eriod S1 5 Timed program One press on S1 5 means 5 min drying time cool down till the air temperature is 40 C or maximum 15 minutes Continued pressings increases the drying time to 10 15 20 30 50 60 7...

Page 8: ...During the heating up the moisture in the machine is indicated by D1 and D2 normally 3 13 D3 and D4 indicate the temperature Fault signals The following codes are indicated by D3 and D4 F2 Maximal dry...

Page 9: ...ing suppIy fuses blown Fuse L1 blown Machine will stop after ca 20 minutes Heater power will be reduced 720W Fuse L2 blown The machine will not start Main power On light extinguished Fuse L3 blown Mac...

Page 10: ...can set this sequence directly and to get an airing program The program unit The program unit has a mecanically marked setting points motor with 4 min stages and built in buzzer Pushbuttons The pushbu...

Page 11: ...heating and when the door is opened Door contact The door contact is activated by the door and breaks the operating circuit Condensate water pump There is a pump in the machine to pump water from the...

Page 12: ...ch The main On Off switch is fitted in the centre of the lower edge of the panel is a 2 pole switch and disconnects the phase and the zero line Indicating lamp The indicating lamp shows that the main...

Page 13: ...Temperature sensing Machine temperature is controlled by a thermistor for exact control If the ther mistor is loose or gets a short circuit the program is stopped See fault signal F3 Moisture sensing...

Page 14: ...eriod S1 5 Timed program One press on S1 5 means 5 min drying time cool down till the air temperature is 35 C or maximum 15 minutes Continued pressings increases the drying time to 10 15 20 30 50 60 7...

Page 15: ...are shut off During the heating up the moisture in the machine is indicated by D1 and D2 normally 3 13 D3 and D4 indicate the temperature Fault signals The following codes are indicated by D3 and D4 F...

Page 16: ...ing suppIy fuses blown Fuse L1 blown Machine will stop after ca 20 minutes Heater power will be reduced 950W Fuse L2 blown The machine will not start Main power On light extinguished Fuse L3 blown Mac...