Thermostats

There are four thermostats : The first is of 47°C and the second of 60°C,  (for
automatic programs) are fitted to the fan casing.
The third of 115°C (resets automatically) operates at 115°C switching out
one of the heaters if the temperature rises excessively. The fourth thermo-
stat, also fitted to the heater casing, operates at 150°C and provides protec-
tion against dangerous overheating. It must be manually reset.

The manual overheating protection breaks the contact to the starter relay,
which means that the machine stops completely when there is overheating.

Signal lamp

The signal lamp indicates that the main switch is ”on”.

Driving motor

The driving motor is a bi-polar unit with direct-coupling fan and gear facility
for driving the drum.

Capacitor

The capacitor is 8 uF mounted on the component bridge.

Heating element

The heating element with 1900 + 950 W output is the spiral type, located
behind the drum.

Contactor and starter relay

The contactor and starter relay are located on the component bridge. The starter
relay breaks contact when there is overheating and when the door is opened.

Door contact

The door contact is actuated by the door, and breaks the operating circuit.

Buzzer

The buzzer is installed in the program unit and gives two signals at end of pro-
gram.

Internal cables

Internal cables are 0,75 or 1,5 mm

2

 and 1,0 mm

2

 for earth wire.

Connecting cables

The connecting cables shall be RKK  or 5x1,5mm

2

Wiring diagrams

Wiring diagrams with timer diagrams and cable layout are incorporated in the
machines.

Summary of Contents for TD70

Page 1: ...INDEX TD70 TD73 TD76 TD77 DRYERS...

Page 2: ...Content Page Tumble dryers TD70A 1 2 TD73A 3 7 TD76A 8 9 TD77A 10 14...

Page 3: ...omatic programs can be started in setting 1 or 2 Setting 2 is more used and gives drying to selected temperature after which the program continues for about 14 minutes without any heat Setting 1 start...

Page 4: ...otor is a bi polar unit with direct coupling fan and gear facility for driving the drum Capacitor The capacitor is 8 uF mounted on the component bridge Heating element The heating element with 1900 95...

Page 5: ...The keyboard includes pushbuttons and indicators Main On Off switch The main On Off switch is fitted in the centre of the lower edge of the panel is a 2 pole switch and disconnects the phase and the z...

Page 6: ...or gets a short circuit the program is stopped See fault signal F3 Moisture sensing A moisture sensor measuring the humidity of the circulating air controls the drying process The output from the sens...

Page 7: ...eriod S1 5 Timed program One press on S1 5 means 5 min drying time cool down till the air temperature is 40 C or maximum 15 minutes Continued pressings increases the drying time to 10 15 20 30 50 60 7...

Page 8: ...During the heating up the moisture in the machine is indicated by D1 and D2 normally 3 13 D3 and D4 indicate the temperature Fault signals The following codes are indicated by D3 and D4 F2 Maximal dry...

Page 9: ...ing suppIy fuses blown Fuse L1 blown Machine will stop after ca 20 minutes Heater power will be reduced 720W Fuse L2 blown The machine will not start Main power On light extinguished Fuse L3 blown Mac...

Page 10: ...can set this sequence directly and to get an airing program The program unit The program unit has a mecanically marked setting points motor with 4 min stages and built in buzzer Pushbuttons The pushbu...

Page 11: ...heating and when the door is opened Door contact The door contact is activated by the door and breaks the operating circuit Condensate water pump There is a pump in the machine to pump water from the...

Page 12: ...ch The main On Off switch is fitted in the centre of the lower edge of the panel is a 2 pole switch and disconnects the phase and the zero line Indicating lamp The indicating lamp shows that the main...

Page 13: ...Temperature sensing Machine temperature is controlled by a thermistor for exact control If the ther mistor is loose or gets a short circuit the program is stopped See fault signal F3 Moisture sensing...

Page 14: ...eriod S1 5 Timed program One press on S1 5 means 5 min drying time cool down till the air temperature is 35 C or maximum 15 minutes Continued pressings increases the drying time to 10 15 20 30 50 60 7...

Page 15: ...are shut off During the heating up the moisture in the machine is indicated by D1 and D2 normally 3 13 D3 and D4 indicate the temperature Fault signals The following codes are indicated by D3 and D4 F...

Page 16: ...ing suppIy fuses blown Fuse L1 blown Machine will stop after ca 20 minutes Heater power will be reduced 950W Fuse L2 blown The machine will not start Main power On light extinguished Fuse L3 blown Mac...

Reviews: