8

BUILT-IN

ASKO dryers can be installed beneath a cabinet 

or worktop with a minimum height of 34" (864 

mm). There must be a gap of about 1/2" (12 mm) 

all around the machine and a minimum gap of 1" 

(25 mm) between the rear edge of the machine top 

panel and the back wall. The opening width must be 

at least 24-1/2" (622 mm). 

The condensing models work best when they have 

good air circulation.

Install the dryer so the condensed water will 

continuously 

fl

 ow into a drain or sink. You will need

a drain outlet behind the unit. The maximum drain 

height is 40" (1016 mm).

  The height adjustment for the dryer is 33- 1/2" to 

34-1/2" (850 mm to 876 mm). Do not raise it higher 

than 34-1/2" (876 mm).

  It is very important to avoid a buildup of heat.

  The warm air that is expelled from the rear of the 

dryer must be able to dissipate.

  Warm air that cannot dissipate could cause a 

fault.

A buildup of heat could be avoided by:

• 

Creating a gap for the dryer in the kitchen 

furniture plinth facing.

• 

Creating ventilation gaps in the kitchen unit.

When build under, drying times may be longer.

  The dryer should not be installed next to a 

refrigeration appliance. The warm air expelled from 

the rear of the dryer would increase the temperature 

around the refrigeration appliance heat exchanger 

causing the compressor to run continuously. If it is 

not possible to install the dryer anywhere else, then 

the refrigeration appliance must be sealed o

  from 

the dryer.

Closet Install- Ventilation Requirements

ASKO's front panel controls make it possible to 

install the washers and dryers in a closet. Make sure 

there is clearance between units and cabinet or wall 

and a 1" (25 mm) minimum clearance between the 

rear edge of the machine top panel and the cabinet 

or wall. To ensure proper ventilation, we recommend 

louvered doors, particularly for condenser dryers. 

Otherwise there must be ventilation openings in 

the door. See illustration for minimum ventilation 

openings below (gray boxes):

  Ensure the dryer door can be opened without 

hindrance after installation.

 The cool air intake panel at the front of the dryer 

must not be blocked or covered. Doing so could 

cause an error.

Summary of Contents for T208C.W.U

Page 1: ...INSTALLATION INSTRUCTIONS TD75 Carefully read the instructions for use before using the dryer Condenser Tumble Dryer DOMESTIC...

Page 2: ...lace the dryer behind lockable or sliding doors or doors with a hinge on the opposite side of the dryer door hinge Install the dryer in such way that the door can always be freely opened Never block t...

Page 3: ...to level the dryer horizontally and vertically by rotating the adjustable feet using a No 22 0 87 spanner max 15 mm 0 59 Then firmly tighten the jam nuts counter nuts by rotating them towards the app...

Page 4: ...ne and dryer are not of matching dimensions or if you have installed a hidden helper between the two appliances then binding plates are available as optional accessories at the service unit available...

Page 5: ...panner The feet allow levelling by 1 cm 0 39 2 After adjusting the height of the feet firmly tighten the jam nuts using a spanner No 17 0 67 by turning them towards the bottom of the washing machine 3...

Page 6: ...1Open the door fully 2Undo the screws and remove the door 3Use the screwdriver to remove the door lock cover and undo the screw on the door lock 4Push the door lock upwards and remove it Move it to th...

Page 7: ...ly to the left hand side Use the screwdriver to remove the plastic part more easily 7Undo the door ring and remove it temporarily 8Rotate the door glass cover by 90 so that the sign indicating the ope...

Page 8: ...reating ventilation gaps in the kitchen unit When build under drying times may be longer The dryer should not be installed next to a refrigeration appliance The warm air expelled from the rear of the...

Page 9: ...2000 mm Run the condensate drain hose into a drain Tie the hose onto a tap B so that it cannot slip during use The drain hose can also be fed into the washbasin siphon C or directly into the floor dr...

Page 10: ...ll be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited Grounding through the neutral conductor is prohibited for new branch circuit instal...

Page 11: ...power supply cord with four No 10 copper wires and a matching 4 wire receptacle of NEMA Type 14 30R as illustrated below The fourth wire must be identified with a white cover and the ground conductor...

Page 12: ...We reserve the right to modifications TD75 SPK DOM US CA en 12 21 US ASKO COM CA ASKO COM ASKO COM MX...

Reviews: