ELECTRICAL INSTALLATION

  The receptacle on the rear of the machine is 

designed to accommodate ASKO washers ONLY 

(rated 208–240 V.) To use this receptacle, you must 

use the ready-fitted plug supplied with the washing 

machine or an equivalent.

ASKO washers rated 208–240 V have two internal 

fuses of 15 A each.

The machine should only be connected to a 

grounded wall socket.

  This appliance must be properly grounded. Refer 

to the “Important Safety Instructions” for grounding 

instructions.

The power supply cord must be grounded. If the 

machine is to be used in a wet area, the supply must 

be protected by a residual current device.

Connection to a permanently wired supply point must 

be made only by a qualified electrician. 

As supplied: Single-phase, 230 V, 60 Hz, 3000W 

heater rating 30 A circuit required.

  Do not connect the machine to the mains 

electricity supply by an extension lead.

Remove cover to access teminal box. 

(Requires- Torx screwdriver.)

Electrical Connections

  Read the Electrical requirements and grounding 

instructions before connecting the tumble dryer.

Electric models of the dryer are manufactured for 

a 3-wire connection system. The dryer frame is 

grounded by a link to the neutral conductor on the 

dryer terminal block. If local codes do not permit 

grounding through the neutral, the grounding link 

from the terminal block must be removed and a 

separate ground wire must be used.

Only a 4-conductor cord shall be used when the 

appliance is installed in a location where grounding 

through the neutral conductor is prohibited. 

Grounding through the neutral conductor is 

prohibited for new branch-circuit installations, 

mobile homes, recreational vehicles, and areas 

where local codes prohibit grounding through the 

neutral conductors. The grounding link on the dryer 

must be removed for all 4-wire installations.

These Electrical Connection instructions provide for 

installing the dryer in the following situations:

3-wire connections where local codes permit 

grounding through the neutral, 3-wire connections 

with a separate grounding connector where local 

codes do not permit grounding through the neutral, 

and 4-wire connections.

Each of the above connections can be made 

with an approved power supply cord or by direct 

wiring. Each connection instruction identi

fi

 es 

the appropriate Power Supply Cord and covers 

requirements for direct wiring.

  In Canada, the dryer is delivered ready-

fi

 tted 

with a four-prong plug intended for connection to a 

single-phase supply.

Connecting a 3-wire Power Cord

  Before starting this procedure, be sure the power 

is turned off at the breaker/fuse box.

Spade terminals 

with upturned 

ends

Ring 

terminals

Ground 

(center)

3/4" UL-listed 

strain relief

Ground

This blade connects to 

this conductor.

3-Wire Cord

Power Supply Cord

You will need a 3-wire power supply cord with 

three No. 10 copper wires and a matching 3-wire 

receptacle of NEMA Type 10-30R, as illustrated 

below:

To connect a 3-wire power cord to the dryer, follow 

the steps below.

  The numbers in the illustration correlate to the 

step numbers.

Summary of Contents for T208C.W.U

Page 1: ...INSTALLATION INSTRUCTIONS TD75 Carefully read the instructions for use before using the dryer Condenser Tumble Dryer DOMESTIC...

Page 2: ...lace the dryer behind lockable or sliding doors or doors with a hinge on the opposite side of the dryer door hinge Install the dryer in such way that the door can always be freely opened Never block t...

Page 3: ...to level the dryer horizontally and vertically by rotating the adjustable feet using a No 22 0 87 spanner max 15 mm 0 59 Then firmly tighten the jam nuts counter nuts by rotating them towards the app...

Page 4: ...ne and dryer are not of matching dimensions or if you have installed a hidden helper between the two appliances then binding plates are available as optional accessories at the service unit available...

Page 5: ...panner The feet allow levelling by 1 cm 0 39 2 After adjusting the height of the feet firmly tighten the jam nuts using a spanner No 17 0 67 by turning them towards the bottom of the washing machine 3...

Page 6: ...1Open the door fully 2Undo the screws and remove the door 3Use the screwdriver to remove the door lock cover and undo the screw on the door lock 4Push the door lock upwards and remove it Move it to th...

Page 7: ...ly to the left hand side Use the screwdriver to remove the plastic part more easily 7Undo the door ring and remove it temporarily 8Rotate the door glass cover by 90 so that the sign indicating the ope...

Page 8: ...reating ventilation gaps in the kitchen unit When build under drying times may be longer The dryer should not be installed next to a refrigeration appliance The warm air expelled from the rear of the...

Page 9: ...2000 mm Run the condensate drain hose into a drain Tie the hose onto a tap B so that it cannot slip during use The drain hose can also be fed into the washbasin siphon C or directly into the floor dr...

Page 10: ...ll be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited Grounding through the neutral conductor is prohibited for new branch circuit instal...

Page 11: ...power supply cord with four No 10 copper wires and a matching 4 wire receptacle of NEMA Type 14 30R as illustrated below The fourth wire must be identified with a white cover and the ground conductor...

Page 12: ...We reserve the right to modifications TD75 SPK DOM US CA en 12 21 US ASKO COM CA ASKO COM ASKO COM MX...

Reviews: