53
Preparation for Work - 6
Ib (L7)
: Base current
Unit
: A
Setting range : 5-200 (DC TIG), 10-200 (AC TIG)
Important! Only selectable when “pulse key” has been pressed.
Fp (L12)
: Pulse frequency
Unit
: Hz
Setting range : 0.5ing
Factory setting : 0.5
Important! Only selectable when “pulse key” has been pressed.
Dcy (L6)
: Pulse Width. Ratio of pulse duration to base current duration
Unit
: %
Setting range : 5ttin
Factory setting : 5
Important! Only selectable when “pulse key” has been pressed.
Tdown (L8)
: Downslope time
Unit
: S
Setting range : 0-10
Factory setting : 0
Ic (L9)
: Crater arc current (only with 4T)
Unit
: S
Setting range : 5-100% of main current Iw
Factory setting : 5
Tpo (L10)
: Gas post-flow time
Unit
: S
Setting range : 0.1:
Factory setting : 3 AC Frequency (only with 4T)
AC Frequency (L5) (only with 4T)
Unit
: Hz
Setting Range
: 50 - 250 (Iw<70A)
50 - 200 (70A≤Iw<100A)
50 - 150 (100A≤Iw<140A)
50 - 120 (140A≤Iw<170A)
50 - 100 (170A≤Iw)
Balance (L11) (only with TIG-AC)
Balance adjustment is mainly used to set the adjustment of eliminating metal-oxide (such as
Aluminium, Magnesium and its alloy) while AC output.
Unit
: %
Setting range : 15 - 50
Factory setting : 15