230V
40-65Hz
140V-300V
Yes
3 Pin 10A, Indian Plug, 1.2 mt wire
230V +10%~-15%
Follows Input
230V ±10%
50 Hz ±1%
Modified Sinewave
0.6
>80%
3 output sockets
UPS output cutoff immediately
110% for 1 min
130% for 3 sec
4-8 ms
12V
7AH, SMF
Auto Discharge Protection
6 hrs (to 90% full capacity)
approx. 10-15 mins
LED steady
LED blink
Slow beeping sound (about 0.47 Hz)
Rapid beeping sound (about 1.8 Hz)
Continuos beeping sound
0-40°C, 0-95% humidity non condensing, 3500 meter max.
<40DbA (1 meter from surface)
15,000 meter max. elevation
4.2 Kgs.
101 x 279 x 142
IND600
1 PC Load (max 600VA)
Capacity
Voltage
Frequency
AVR
Generator Compatible
Connection
Voltage on mains
Frequency on mains
Voltage on Battery
Freq on Battery
Waveform
Power Factor Lagging
Efficiency
Sockets
O/p Short cct
O/p overload shutdown
Mains to Inverter
DC Bus
Internal Battery
Proctection
Typical Recharging Time
Backup time on PC
with LCD monitor
Power ON
Inverter ON
Battery Backup
Battery Low
Overload
Ambient Operation
Audible Noise
Storage Condition
Weight (Kgs.)
Dimension - WxDxH (mm)
Features
!
Line interactive design
!
Boost and buck AVR (Auto voltage
regulation)
!
Cold start function (DC power on)
!
Advanced battery management
(ABM technology)
!
Battery charging in UPS OFF Mode
!
Microprocessor controlled
Specifications -
IND600
Model
Input
Output
Protection
Transfer Time
Battery
Indications
Alarm
Environment
Physical
ASIA POWERCOM PVT. LTD.
H.O.:
401, 402 4th Floor,Arya Arcade CHS, Station Road, Vikhroli West , Mumbai - 400083.
[email protected] • [email protected] • www.asiapowercom.com
Error/Problem
No LED
display
on the
front panel.
Alarm buzzer
beeps
continuously
when AC
supply is
normal.
When Power
failure, backup
time is
shortened.
Possible cause
Battery defect.
Power switch is
not pressed
.
Overload of
the UPS.
Overload of
the UPS.
Battery voltage
is too low.
Battery defect
due to high
temp. operation
environment, or
improper
operation
of battery.
Remedy
Charge battery
up to 8 hours.
Replace with the
same type
of battery.
Press the power
switch again.
Verify that the
load matches the
UPS capability
specified in the
specs.
Remove some
noncritical load.
Charge battery
16 hrs. or more.
Replace with the
same type of
battery.
TROUBLESHOOTING
Use the table below to solve minor UPS
installation or operation problems. If any
abnormal situation occur that are not
listed above, please call service people
immediately.