IMPROPER INSTALLATION
The use of other components other than stated
herein could cause bodily harm, heater damage,
and void your warranty. The manufacturer will not
be held responsible for damage caused by the
malfunction of a stove due to improper venting or
installation.
FLOOR PROTECTION
This heater must have a non-combustible floor
protector (UL1618 ember protection) installed
beneath it if the floor is of combustible material.
US:
The floor pad or non-combustible surface
should be large enough to cover at least the area
under the product and 6” (152 mm) beyond the
front and beyond each side of the fuel loading
and ash removal openings. Floor protection must
extend under and 2” (51 mm) to each side of the
chimney tee for an interior vertical installation.
Canada:
Require a minimum of 475 mm [18”]
beyond the front of the unit and 203 mm [8”]
beyond each side of the unit. A Floor Protector of
1/4 inch thick is recommended for this installation.
B
B
C
Floor Protector
A
Floor Protector
D
A Rear
1”
25 mm
B Side
USA
6”
153 mm
CAN 8” 203 mm
C Front
USA
6”
153 mm
CAN 18” 475 mm
D Rear
2”
50 mm
CLEARANCES
Your pellet stove has been tested and listed for
installation in residential, mobile home, and alcove
applications in accordance with the clearances given
in this manual. For safety reasons, please adhere
to the installation clearances and restrictions. Any
reduction in clearance to combustibles may only be
done by means approved by a regulatory authority.
E
F
G
E
F
G
H
H
H
H
TABLE 1 CLEARANCES
in mm
PARALLEL
E
Back wall to unit
3
76
F
Sidewall to flue
11
280
G
Sidewall to top edge
of unit
8
203
CORNER
H
Adjacent wall to unit
8
203
INSTALLATION