10
© 2021 United States Stove Company
on the heat range “1” setting.
•
During start up the heat level advance (Up and
Down keys) will change the heat range indicator
level accordingly, but there is no change in the
stoves operating conditions until start-up is
completed.
• During start-up ignition must occur within 12
minutes or the stove will error out and show E3.
•
During the start-up phase, the Mode key does not
function.
B.
Heat Range Arrow Buttons
•
These buttons when pushed will set the pellet
feed rate, hence the heat output or heat range
of your stove. When using the hand-held remote
this function can be performed with the “Up/
Down” buttons.
•
The levels of heat output will incrementally
change on the bar graph starting from heat
range “1” to heat range “5”.
CONTROL PANEL OVERVIEW
Turning the heater ON/OFF, as well as adjustments
for the fuel feed rate and room fan speed are
performed by pressing the appropriate button(s)
on the control panel which is located on the lower
left-hand side of your heater.
•
ON/OFF
Pressing the “ON” button on the control panel will
begin the start-up sequence for the heater. Fuel
will begin to feed through the auger feed system
then ignite after approximately 5 minutes.
Pressing the “OFF” button on the control panel will
cause the heater to enter its shut-down sequence.
The fuel feed system will stop pulling fuel from the
hopper and, once the fire goes out and the heater
cools down, the fans will stop running.
•
HEAT RANGE
Pressing the “Heat Range” arrows, up or down, will
adjust the amount of fuel being delivered to the
burnpot.
•
DRAFT FAN
The draft fan (exhaust) will come on as soon as the
“ON” button is pressed. The fan will automatically
adjust its speed in accordance to the heat range
setting. However, this speed can be manually
operated by pressing the “Draft Fan” arrows up or
down. “Draft Fan” when pressed, the display will
show “Df-A”, which is automatic. Press the arrows
again to adjust fan speed. When the heater is in
the manual mode, the optional thermostat will
not properly control the unit. When adjusting the
Draft Fan setting, try only 1 setting above or below
the heat setting. It is better to leave the stove in the
automatic mode.
•
ROOM FAN
The room fan will come on once the unit has
reached operating temperature. By pressing the
“Room Fan” buttons, the display will show “Rf-
A” which is automatic or “Rf-1” through “Rf-9” for
manual settings. In auto mode, the room fan’s
speed will automatically be adjusted in accordance
with the heat range setting. By pressing the “Room
Fan” up arrow, you can adjust the fan speed setting
up to “Rf-9”. The room fan must operate at a level
greater than or equal to the heat range setting.
•
AUX - USED TO RETURN THE STOVE TO THE
FACTORY SETTINGS
To return the stove to it’s original factory settings,
press and hold the AUX UP and AUX DOWN buttons
simultaneously for 3 seconds.
•
AUGER DELAY
The “Auger Delay” button can be used to pause
rotation of the Auger for approximately 1 minute.
This can be cancelled by pressing the “ON” button.
The “Auger Delay” is normally used only during the
start up cycle to slow the fuel delivery down during
the initial ignition.
•
MODE
The “Mode” button is not used on this model.
During normal operation, the unit is constantly
monitored for problems. In the event of an error
condition, the unit will stop and an error will be
displayed. See the list of error codes found at the
end of this manual.