SAFETY NOTICE:

If this heater is not properly installed, a house fire 

may result.  For your safety, follow the installation 

instructions. Never use make-shift compromises 

during the installation of this heater. Contact local 

building or fire officials about permits, restrictions 

and installation requirements in your area.

CAUTION!

Please read this entire manual before you install 

or use your new room heater. Failure to follow 

instructions may result in property damage, 

bodily injury, or even death.

Improper Installation Could Void

Your Warranty!

CONFORMS TO UL STD 1482 and CERTIFIED TO ULC STD S627

WASHINGTON STATE APPROVED

MOBILE HOME APPROVED (U.S. ONLY)

United States Stove Company

227 Industrial Park Road

P.O. Box 151

South Pittsburg, TN 37380

800-750-2723

SAVE THESE INSTRUCTIONS

THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU 

TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

852087F-0902G

MODEL: AC2000

French version is available for download from the U. S. Stove website: http://www.usstove.com/

La version française est disponible pour téléchargement à partir du site U. S. Stove: http://www.usstove.com/

U.S. Environmental Protection Agency 

Certified to comply with 2015 particulate emissions standards.

Owner’s Operation and Instruction Manual

Summary of Contents for AC2000

Page 1: ...L STD 1482 and CERTIFIED TO ULC STD S627 WASHINGTON STATE APPROVED MOBILE HOME APPROVED U S ONLY United States Stove Company 227 Industrial Park Road P O Box 151 South Pittsburg TN 37380 800 750 2723 SAVE THESE INSTRUCTIONS THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE 852087...

Page 2: ... s are based on the first hour of operation at high burn rate burning cordwood CAUTIONS Hot while in operation Keep children clothing and furniture away Contact may cause skin burns Do not use chemicals or fluids to ignite the fire Do not leave the stove unattended when the door is slightly opened Do not burn garbage flammable fluid such as gasoline naphtha or motor oil Do not connect to any air d...

Page 3: ...ponents required for your particular chimney installation For mobile homes see page 13 ASSEMBLY Flue Collar Assembly 1 Mount the flue collar to the top of the unit as shown using the 3 5 16 18 x 1 1 2 bolts 3 washers and 3 weld tabs provided in the parts box Room Air Deflector Assembly 1 Locate the Room Air Deflector Mount the deflector to the unit using the three 3 1 2 Tek Screws provided may be ...

Page 4: ...MARKED TO INDICATE SUCH USE DO NOT ROUTE THE SUPPLY CORD NEAR OR ACROSS HOT SURFACES Step 1 Fix the assembly to the back of the stove with the four screws provided CUT ENDS OF GALSS GASKET SHALL MEET AT THE BOTTOM CENTER OF THE GLASS CUT ENDS OF GASKET SHALL MEET BETWEEN HINGE LUGS 8 4 9 6 5 ASH PAN ASSEMBLY Remove ash pan from firebox Under the firebox there are two brackets Slide the ash pan int...

Page 5: ... air into the room or space heated shall be provided when required POSITIONING THE STOVE It is very important to position the wood stove as close as possible to the chimney and in an area that will favor the most efficient heat distribution possible throughout the house The stove must therefore be installed in the room where the most time is spent and in the most spacious room possible Recall that...

Page 6: ...section of chimney connector the floor protector should go under it and 2 inches beyond each side To calculate R Values for alternative methods see ALTERNATE FLOOR PROTECTOR CALCULATIONS section in this manual The floor protector should exceed the stove as follows Dimension Inch mm H Front 16 635 J Left 6 153 K Right 6 153 L Back 1 25 M Total Width 46 1169 N Total Length 53 5 1359 Canadian install...

Page 7: ...nnector must not pass through an attic or roof space closet or similar concealed space a floor or a ceiling For Canadian installations where passage through a wall or partition of combustible construction is desired the installation must conform to CAN CSA B365 A flue pipe crossing a combustible wall must have a minimum clearance of 18 457 2mm To reduce flue clearances from combustible materials c...

Page 8: ...g pipe should never exceed 8 to 10 2 4m to 3 04 m Except for cases of vertical installation cathedral roof style where the smoke exhaust system can be much longer and connected without problem to the chimney at the ceiling of the room There should never be more than two 90 degrees elbows in the smoke exhaust system Installation of a barometric draft stabilizer fireplace register on a smoke exhaust...

Page 9: ...himney fires Note that it is the chimney and not the stove which creates the draft effect your stove s performance is directly dependent on an adequate draft from your chimney The following recommendations may be useful for the installation of your chimney 1 Do not connect this unit to a chimney flue serving another appliance 2 It must rise above the roof at least 3 0 9m from the uppermost point o...

Page 10: ...same manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance to the structure as recommended by the manufacturer The chimney must be the required height above the roof or other obstructions for safety and proper draft operation ...

Page 11: ...ssociation NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove through a combustible wall to a masonry chimney special methods are needed ...

Page 12: ...ch has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiberglass insulation from the outer surface of the wall thimble to wall combustibles Support the wall thimble and cover its opening with a 24 gage minimum sheet metal support Maintain the 6 152 4 mm space There should also be a support sized to fit and hold the me...

Page 13: ...uffer smoke roll out when opened or back drafts occur whether or not there is combustion present 4 Opening a window slightly on a calm windless day alleviates any of the above symptoms 5 The house is equipped with a well sealed vapor barrier and tight fitting windows and or has any powered devices that exhaust house air 6 There is excessive condensation on windows in the winter 7 A ventilation sys...

Page 14: ...and stacking wood before it is stored accelerates drying time Storing wood on an elevated surface from the ground and under a cover or covered area from rain or snow also accelerates drying time A good indicator if wood is ready to burn is to check the piece ends If there are cracks radiating in all directions from the center then the wood should be dry enough to burn If your wood sizzles in the f...

Page 15: ...ween Then a fourth layer of loose small kindling and twisted newspaper sheets tops off the pile Before igniting the paper and kindling wood it is recommended that you warm up the chimney This is done in order to avoid back draft problems often due to negative pressure in the house If such is the case open a window slightly near the stove and twist together a few sheets of newspaper into a torch Li...

Page 16: ...earn to adjust the air settings of your specific unit to produce the smallest amount of visible smoke Wood that has not been seasoned properly and has a high wood moisture content will produce excess visible smoke and burn poorly RELOADING Once you have obtained a good bed of embers you should reload the unit In order to do so open the air controls to maximum a few seconds prior to opening the sto...

Page 17: ...e While the modern combustion systems in heaters drastically reduce the amount of CO emitted out the chimney exposure to the gases in closed or confined areas can be dangerous Make sure you stove gaskets and chimney joints are in good working order and sealing properly to ensure unintended exposure It is recommended that you use both smoke and CO monitors in areas having the potential to generate ...

Page 18: ...d one Carefully clean the available gasket groove apply a high temperature silicone sold for this purpose and install the new gasket You may light up your stove again approximately 24 hours after having completed this operation This unit s door uses a 1 2 diameter rope gasket HIGH TEMPERATURE STOVE PAINT REPAIR If the painted portions of your stove need re coating it is possible to give those piec...

Page 19: ...rushed Nickel 1 8 69767 Ash Pan Weldment 1 9 40589 Front 1 10 40588 Side 2 11 40292A 6 Flue Collar 1 12 40587 Top 1 13 26934 Air Deflector 1 14 891841 Assembly AFS Blower 1 15 26335 Heat Shield 1 16 69768 Weldment Ash Pan Housing 1 17 40566 Leg Cast Iron 4 In order to maintain warranty components must be replaced using original manufacturers parts purchased through your dealer or directly from the...

Page 20: ...Key Part No Description Qty 1 891414 Half Firebrick 2 2 89066 Firebrick 4 1 2 X 9 14 3 24103 Firebrick Half 4 1 2 X 4 1 2 2 4 40561 Ash Plug 1 5 86643 Tube Ø5 32 Secondary Air 1 6 86645 Tube Ø7 32 Secondary Air 2 7 88146 Board Ceramic Fiber 1 4 3 3 1 6 7 5 In order to maintain warranty components must be replaced using original manufacturers parts purchased through your dealer or directly from the...

Page 21: ...protector system is equal to or greater than the floor protector specifications given the alternate is acceptable Definitions Thermal conductance C Thermal conductivity k Thermal resistance R Example The specs of floor protector material should be 3 4 inch thick material with a k factor of 0 84 The proposed alternative material is 4 brick with a C factor of 1 25 over 1 8 inch mineral board with a ...

Page 22: ... 22 NOTES ...

Page 23: ...tten warranty or any implied warranty 2 Should the heater be replaced by United States Stove Company free of charge all further warranty obligations are thereby met 3 Parts and or service replacements made under the terms of this warranty are warranted only for the remaining period of the original heater warranty 4 Without specific written exclusionary waivers no one has authority to add to or vary...

Page 24: ...ompany ________________________________________ Telephone No ______________________________________ Stove Inspected Chimney Swept Items Replaced ____________________________________ Service 05 Date ________________________ Engineer Name _____________________________________ Company __________________________________________ Telephone No ______________________________________ Stove Inspected Chimne...

Page 25: ...ous écrivez veuillez indiquer le numéro complet du modèle qui figure sur la plaque signalétique de l appareil de chauffage Lorsque vous commandez des pièces de rechange veuillez toujours fournir les renseignements suivants tels que montrés dans cette nomenclature 1 The part number Le numéro de pièce_____________________________________________________________ 2 The part description La description ...

Page 26: ...___________________ Company__________________________________________ N de téléphone ___________________________________ Poêle Inspecté Cheminée Swept Articles Remplacé __________________________________ Date________________________ Ingénieur Nom _____________________________________ Service de 06 Refustratuib No ____________________________________ Company_________________________________________...

Page 27: ... dommages éventuels que quiconque pourrait subir à la suite d une violation de cette garantie écrite ou de toute garantie implicite 2 Si l appareil de chauffage est remplacé gratuitement par United States Stove Company toutes les autres obligations de garantie sont ainsi satisfaites 3 Le remplacement des pièces et ou le service effectués en vertu des modalités de cette garantie sont garantis uniqu...

Page 28: ...R globale Si la valeur R globale du système de protection du plancher est égale ou supérieure aux spécifications de protection de plancher données les matériaux sont alors acceptables Définitions Conductance thermique C Conductivité thermique k Résistance thermique R Exemple Les spécifications de matériau du protecteur de plancher doivent être un matériau d une épaisseur de 3 4 po avec un facteur ...

Page 29: ...scription Qté 1 891414 Demi brique 2 2 89066 Brique de feu 4 1 2 X 9 14 3 24103 Brique de feu moitié 4 1 2 X 4 1 2 2 4 40561 Bouchon de cendres 1 5 86643 Tube Ø5 32 air secondaire 1 6 86645 Tube Ø7 32 air secondaire 2 7 88146 Panneau fibre céramique 1 4 3 3 1 6 7 5 Afin de maintenir la garantie les composants doivent être remplacés à l aide des pièces d origine du fabricant achetées par le biais d...

Page 30: ...ossé 1 8 69767 Soudage de cendres 1 9 40589 De face 1 10 40588 Côté 2 11 40292A Collier de fumée de 6 po 1 12 40587 Haut 1 13 26934 Déflecteur d air 1 14 891841 Assemblée AFS Souffleur 1 15 26335 Bouclier thermique 1 16 69768 Soudure Cendrier 1 17 40566 Jambe fonte 4 Afin de maintenir la garantie les composants doivent être remplacés à l aide des pièces d origine du fabricant achetées par le biais...

Page 31: ...égratigner Utilisez un produit spécialisé offert dans les magasins où les poêles à bois sont vendus Le verre ne doit être lavé que lorsqu il est froid JOINTS D ÉTANCHÉITÉ Il est recommandé de remplacer le joint d étanchéité qui assure l étanchéité du poêle une fois par an afin d assurer un bon contrôle de la combustion ainsi qu un maximum d efficacité et de sécurité Pour remplacer le joint de port...

Page 32: ...es et que le feu est éteint et froid retirez les cendres en excès Laissez un lit de cendres d environ 3 cm 1 po d épaisseur sur le fond de la boîte à feu pour aider à conserver une couche chaude de charbon Les cendres doivent être placées dans un récipient en métal recouvert d un couvercle bien ajusté Le récipient de cendres fermé doit être placé sur un plancher incombustible ou sur le sol loin de...

Page 33: ... atteindre des efficacités optimales est d apprendre les caractéristiques de brûlage de votre appareil et du bois bien séché Des taux de combustion plus élevés ne sont pas toujours les meilleurs taux de combustion après qu un bon feu est établi un taux de combustion plus bas peut être la meilleure option pour un chauffage efficace Un taux de combustion plus bas ralentit la sortie du flux de chaleu...

Page 34: ...on de votre poêle N ouvrez jamais le régulateur d air plus que nécessaire pour obtenir une vitesse de combustion moyenne Assurez vous qu il y ait une circulation d air suffisante lorsque vous traitez la peinture du poêle Des odeurs peuvent être senties au cours des 3 ou 4 premiers feux N allumez jamais votre poêle à l extérieur Vous ne serez pas en mesure de voir s il surchauffe ALLUMAGE La méthod...

Page 35: ... séché Le bois mort peut normalement être considéré comme sec à 66 Fendre et empiler le bois avant de l entreposer accélère son séchage Entreposez le bois sur une surface surélevée du sol et sous un espace abrité de la pluie ou de la neige accélèrera le temps de séchage Un bon indicateur pour savoir si le bois est prêt à brûler est de vérifier les extrémités du morceau Si elles sont fendues de tou...

Page 36: ...onctionnement de retours de fumée lors de l ouverture du poêle ou de refoulements d air qu il y ait de la combustion ou pas Ouvrez légèrement une fenêtre lors d une journée sans vent atténue tous ces symptômes La maison est dotée d une barrière à vapeur bien scellée et des fenêtres hermétiques et ou des dispositifs électriques qui évacuent l air de la maison Une concentration excessive de condensa...

Page 37: ...ment de 50 8 mm 2 po par rapport à un composant de mur combustible commencez par une section de cheminée préfabriquée homologuée Solid Pak d au moins 304 mm 12 po de longueur avec isolation de 25 4 mm 1 po ou plus et d un diamètre interne de 8 po 2 po 51 mm plus grand que le conduit de raccordement de la cheminée de 6 po 152 4 mm Utilisez cette section en tant que passage pour un conduit de raccor...

Page 38: ...on et d obstruction Faites nettoyer la cheminée avant l installation ou l utilisation du poêle Des méthodes spéciales sont requises lors du raccordement du poêle par un mur combustible à une cheminée en maçonnerie Chapeau en béton Dégagement de 1 po avec le coupe feu Chevron Solin Boisseau en argile réfractaire avec espace d air Solin Dégagement de 25 mm 1 po Revêtement Porte de nettoyage étanche ...

Page 39: ...agements appropriés par rapport à la structure tel que recommandé par le fabricant La cheminée doit être à la hauteur exigée au dessus du toit ou de toute obstruction afin d assurer un fonctionnement sécuritaire et approprié du tirage Écran d isolation du grenier Dégagement spécifié Support de plafond Vers le poêle Vers le poêle Conduit de raccordement de cheminée Support de plafond Cheminée homol...

Page 40: ...ie de cheminée Veuillez prendre note que c est la cheminée et non le poêle qui crée l effet de tirage Le rendement de votre cheminée est donc directement dépendant d un tirage adéquat de la cheminée Les recommandations suivantes peuvent s avérer utiles lors de l installation de la cheminée 1 Ne reliez pas cet appareil à un conduit de fumée utilisé pour un autre appareil 2 Elle doit dépasser le toi...

Page 41: ...erticales de style toit cathédrale où le système d évacuation de la fumée peut être plus long et raccordé sans problème à la cheminée au niveau du plafond de la pièce L installation du système d évacuation de la fumée ne doit pas comporter plus de deux coudes de 90 degrés Il est interdit d installer un stabilisateur de tirage barométrique registre de cheminée sur un système d évacuation de la fumé...

Page 42: ...plancher et un plafond Pour les installations au Canada lorsqu on souhaite passer un tuyau dans un mur ou une cloison de construction combustible l installation doit alors se conformer à CAN CSA B365 Le dégagement minimum d un tuyau de raccordement passant par un mur combustible est de 457 2 mm 18 po Communiquez avec le département local de sécurité si vous souhaitez réduire les dégagements entre ...

Page 43: ...cteur de plancher doit passer sous la section horizontale et au delà de 5 cm 2 po chaque côté Pour calculer les valeurs R pour d autres méthodes consultez la section CALCULS POUR D AUTRES PROTECTEURS DE PLANCHER dans ce manuel Le protecteur de plancher doit excéder le poêle comme suit Dimensions En pouces En mm H Avant 16 635 J Gauche 6 153 K Droite 6 153 L Arrière 1 25 M Largeur totale 46 1169 N ...

Page 44: ...tribution d air Au besoin fournissez une source d air frais dans la pièce ou à un espace chauffé POSITIONNEMENT DU POÊLE Il est très important de choisir un emplacement le plus près possible de la cheminée dans une zone favorisant la meilleure distribution de chaleur possible à travers la maison Par conséquent le poêle doit être installé dans la pièce où les occupants de la maison passent le plus ...

Page 45: ...TATION PRÈS OU À TRAVERS DES SURFACES CHAUDES Étape 1 Fixez la soufflante à l arrière du poêle à l aide des quatre boulons fournis LES EXTRÉMITÉS COUPÉES DU JOINT DE VERRE DOIVENT SE RENCONTRER AU BAS ET AU CENTRE DU VERRE C LES EXTRÉMITÉS COUPÉES DU JOINT DE VERRE DOIVENT SE RENCONTRER ENTRE LES PATTES D ARTICULATION 8 4 9 6 5 Panier à braise Retirez le panier à braise du foyer Deux supports sont...

Page 46: ... la page 13 ASSEMBLAGE Buse 1 Installer la buse au haut de l appareil tel que montré en utilisant les 3 boulons 5 16 18 x 1 1 2 boulons 3 rondelles et 3 patte soudée fournis dans la boîte de pièces Déflecteur d air ambiant 1 Localiser le déflecteur d air ambiant À l aide des trois 3 boulons Tek de 1 2 po fournies installez le déflecteur sur l unité tel que montré sur le schéma Disposition de la br...

Page 47: ...n brûlant du bois de corde MISES EN GARDE Chaud lors du fonctionnement Gardez les enfants les vêtements et les meubles éloignés de l appareil Un contact peut causer des brûlures à la peau N utilisez pas de produits chimiques ou de fluides pour allumer le feu Ne laissez jamais le poêle sans surveillance lorsque la porte est ouverte même légèrement Ne brûlez pas de déchets ou de fluides inflammables...

Page 48: ...tion peut annuler la garantie CONFORME À LA NORME UL 1482 ET CERTIFIÉ À LA NORME ULC S627 POÊLE À BOIS CERTIFIÉ ENVIRONMENTAL PROTECTION AGENCY É U PHASE II INSTALLATION APPROUVÉE PAR L ÉTAT DE WASHINGTON INSTALLATION APPROUVÉE DANS LES MAISONS MOBILES É U SEUL United States Stove Company 227 Industrial Park Road P O Box 151 South Pittsburg TN 37380 CONSERVEZ CES INSTRUCTIONS CE MANUEL VOUS AIDERA...