Ashland SWH300 Operation, Performance, Specifications And Parts Manual Download Page 6

6

Sewage Pumps

Model: SWH300/SWH500 & SWHD300/SWHD500 

Receiving and Installation

It is recommended that the level control float should be  

set to insure that the liquid in the sump never drops  

below the top of the motor housing. The level control

should have adequate clearance so it cannot hang up in  

it’s swing and that the pump is completely submerged

when the level control is in the “Off ” mode. Minimum 

tether length is 3.50”. 
By adjusting the cord tether the control level can be 

changed. DO NOT USE THE POWER CABLE TO LIFT 

PUMP. 
 Pump-Down Test - Be sure pump has been plugged in,   

lowered into the basin or sump, check the system by    

filling with liquid and allowing the pump to operate  

 

 through its pumping cycle. The time needed to

 empty the system, or pump-down time along with the    

volume of water, should be recorded.

Thermal Protection

Motors are protected by a thermo-overload or thermo 

sensor depending on the model and single or three 

phase.

 

Maintenance

Minimal maintenance is required. Perform the following 

checks when pump is removed from operation or when 

pump performance deteriorates:

  a).  Inspect motor chambers for oil level and   

 

   

contamination.

  b).  Inspect impeller and body for excessive build-up or  

   

clogging.

  c).  Inspect motor and bearings.

  d). Inspect seal for wear or leakage.
 

Servicing

Cooling Oil

 - Anytime the pump is removed from  

operation, the cooling oil in the motor housing should be 

checked visually for oil level and contamination. To check 

oil, set unit upright. Remove pipe plug from housing. 

With a flashlight, visually inspect the oil in the housing to 

make sure it is clean and clear, light amber in color and 

free from suspended particles. Milky white oil indicates 

the presence of water. Oil level should be just above the 

motor when pump is in vertical position. 

Oil Testing

•  Drain oil into a clean, dry container by placing pump on  

  it’s side. Remove pipe plug, from housing.

•  Check oil for contamination using an oil tester with a   

  range to 30 Kilovolts breakdown.

•  If oil is found to be clean and uncontaminated  

  (measuring above 15 KV. breakdown), refill the housing.

•  If oil is found to be dirty or contaminated (or measures  

  below 15 KV. breakdown), the pump must be carefully  

  inspected for leaks at the shaft seal, cable assembly,   

  o- ring and pipe plug, before refilling with oil. To locate  

  the leak, perform the following pressure tests.
After leak is repaired, dispose of old oil properly, and 

refill with new oil. 

     

Pressure builds up extremely fast, increase    

    

pressure by “TAPPING” air nozzle. Too much

    

pressure will damage seal.    

 

 

    

DO NOT exceed 10 P.S.I.

Motor Housing Pressure Test:

If oil has been drained, fill to normal level before perform-

ing pressure test. Remove pipe plug from motor housing.
Apply pipe sealant to pressure gauge assembly and tight-

en into hole. Pressurize motor housing to 10 P.S.I. Use 

soap solution around the sealed areas above the oil level 

and inspect joints for “air bubbles”. For sealed areas 

below oil level, leeks will seep oil. If, after five minutes, 

the pressure is still holding constant, and no “bubbles” /

oil seepage is observed, slowly bleed the pressure and 

remove the gauge assembly. Replace oil. Leak must be 

located and repaired if pressure does not hold.

Oil Replacement Motor Housing 

Remove pipe plug from motor housing.
Drain all oil (if not already done so) from motor housing  

and dispose of properly per Local Code. Set pump 

upright and refill with new cooling oil, see “Cooling 

Oil” chart. Fill to just above motor (1.2L) as an air space 

must remain in the top of the motor housing to compen-

sate for oil expansion. Apply pipe thread compound to 

threads of pipe plug then assemble to motor housing. 

Check that o-ring is in place and does not need to be 

replaced. Reassemble cord cap to motor housing.
   

DO NOT overfill oil. Overfilling of housing    

   

with oil can create excessive and dangerous  

   

hydraulic pressure which can destroy the    

   

pump and create a hazard. Overfilling  

 

   

oil voids warranty.

 

   

Cooling Oil Recommended Supplier/Grade

  BP  

  Enerpar SE100

  Conoco  

  Pale Paraffin 22

  Mobile  

  D.T.E. Oil Light

  Shell Canada  

  Transformer-10

  Texaco  

  Diala-Oil-AX

   

 

 

       Before any service work is   

   

 

 

       done, disconnect and lock  

   

out electrical power to pump. 

 

WARNING

 

   

Summary of Contents for SWH300

Page 1: ...hin one year be returned to us with transportation charges prepaid and proved to be defective The above limited warranty takes the place of all other warranties express or implied and correction of su...

Page 2: ...h pumped fluid is possible Risk of electrical shock To reduce risk of electrical shock always disconnect pump from source before handling Lock out power tag Sewage Pumps Model SWH300 SWH500 SWHD300 SW...

Page 3: ...D SOW 8AWG 4C 1 0 Cast Iron Cast Iron Cast Iron SS SWHD300M6 20 3 60 208 3 1750 18 0 D SOW 12AWG 4C 7 Cast Iron Cast Iron Cast Iron SS SWH500M2 20 5 60 230 1 1750 40 0 D SOW 6AWG 4C 1 2 Cast Iron Cas...

Page 4: ...GALLONS PER MINUTE SWH300 SWHD300 PERFORMANCE HEAD FEET 70 60 50 40 30 20 10 0 0 50 100 150 200 250 300 350 400 450 GALLONS PER MINUTE Description To pump domestic commercial and light industrial sew...

Page 5: ...se assembly to the pump Discharge piping should be as short as possible and sized no smaller than the pump discharge Do not reduce the discharge pipe size below that which is provided on the pump Both...

Page 6: ...f oil is found to be clean and uncontaminated measuring above 15 KV breakdown refill the housing If oil is found to be dirty or contaminated or measures below 15 KV breakdown the pump must be carefull...

Page 7: ...d the rotor and press the upper bearing on the rotor shaft applying force to the inner race of the bearing only In the same manner replace lower bearing 49 onto rotor shaft Seal Plate Lubricate and se...

Page 8: ...to cool to room temperature Installing Pump in Sump These pumps are usually installed in concrete or fiberglass basins with the lift out rail system Figure 3 shows pump mounted on the rail system Inst...

Page 9: ...and stop several times by plugging and unplugging cord Check for clogged vent hole in pump case Inlet holes in pump base are clogged Remove pump and clean the openings Vertical pumping distance is to...

Page 10: ...10 Sewage Pumps Model SWH300 SWH500 Series Parts MOTOR PARTS GROUP WET END PARTS GROUP...

Page 11: ...091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 11 WASHER 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 1 12 CONDUIT BUSHING 091SW3014 091SW3014 091SW3014 091SW3...

Page 12: ...12 Sewage Pumps Model SWHD300 SWHD500 Series Parts WET END PARTS GROU MOTOR PARTS GROUP WET END PARTS GROUP...

Page 13: ...SWD318 091SWD318 091SWD318 1 19 BEARING 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 20 ROTOR ASSY 091SWD320 091SWD320 091SWD320 091SWD320 091S...

Page 14: ...14 1899 Cottage Street Ashland Ohio 44805 Telephone 855 281 6830 Fax 877 326 1994 ashlandpump com P U M P H o n e s t P r o f e s s i o n a l D e p e n d a b l e AP SWH300 500 SWHD300 500 OM 03 2018...

Page 15: ...ecci n de dichos defectos por sustituci n o reparaci n debe constituir el cumplimiento de todas las obligacciones bajo los t rminos de la garant a cual EXCLUYE espec ficamente cualquier da o incidenta...

Page 16: ...de agua potable Las instalaciones cableado y conex iones de empalmes deben realizarse en concordancia con el C digo de Electricidad Nacional y con todos los c digos estatales y locales pertinentes Los...

Page 17: ...08 1 1750 33 5 D SOW 8AWG 4C 1 0 Hierro Fundido Hierro Fundido Hierro Fundido Acero SWHD300M6 20 3 60 208 3 1750 18 0 D SOW 12AWG 4C 7 Hierro Fundido Hierro Fundido Hierro Fundido Acero SWH500M2 20 5...

Page 18: ...6206 Bombas de Agua Residual Modelo SWH300 SWH500 SWHD300 SWHD500 Especificaciones y Funcionamiento Total Elevar pulgada 0 15 20 30 40 53 GPM 370 320 292 225 130 0 Total Elevar pulgada 0 15 20 30 40...

Page 19: ...la bomba La tuber a de descarga debe ser lo m s corta posible y de tama o no menor Que la descarga de la bomba No reduzca el tama o de tuber a de descarga Debajo de lo que se proporciona la bomba Se...

Page 20: ...encuentra el aceite por limpiar medici n por encima de 15 kv Desglose llene el c rter haga Las siguientes pruebas de presi n Si se encuentra el aceite sucio o contaminado medici n por encima De 15 kv...

Page 21: ...ando fuerza para la carrera interior Del cojinete solamente De la misma manera reemplace el cojinete inferior En el eje del rotor Placa de Sello Lubrique y ponga el o anillo en la parte inferior de la...

Page 22: ...s bombas sin el sistema ferroviario excepto en sistemas envasados especial de o e m deben instalar las v lvulas de retenci n siempre juntas con v lvulas de cierre Esto permite un servicio m s F cil y...

Page 23: ...rada en la carcasa de la bomba est n obstruidas Retire la bomba y Limpie las aberturas La distancia vertical de bombeo es demasiado alta Reduzca la distancia o cambie Los accesorios de descarga de la...

Page 24: ...24 Bombas de Agua Residual Modelos SWH300 SWH500 Series Piezas GRUPO DE PIEZAS SUMERGIBLES GRUPO DE PIEZAS DEL MOTOR...

Page 25: ...W3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 11 ARANDELA 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 1 12 CASQU...

Page 26: ...26 Bombas de Agua Residual Modelos SWHD300 SWHD500 Series Piezas WET END PARTS GRO GRUPO DE PIEZAS SUMERGIBLES GRUPO DE PIEZAS DEL MOTOR...

Page 27: ...091SWD318 091SWD318 091SWD318 1 19 COJINETE 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 20 EL CONJUNTO DEL ROTOR 091SWD320 091SWD320 091SWD32...

Page 28: ...1899 Cottage Street Ashland Ohio 44805 Telefono 855 281 6830 Fax 877 326 1994 ashlandpump com B O M B A H o n e s t o P r o f e s i o n a l C o n f i a b l e 28 AP SWH300 500 SWHD300 500 OM 03 2018...

Page 29: ...stallation ou 18 mois compter de la date de fabrication selon la premi re ventualit L obligation sous cette garantie est limit la r paration ou au rem placement de toute partie de celle ci qui sont mo...

Page 30: ...la source d alimentation avant de les manipuler Verrouiller l alimentation tag Le puisard et les pompes d eaux us es manipulent souvent des mat riaux qui pourraient causer une maladie ou d une maladi...

Page 31: ...x SWHD300M5 20 3 60 208 1 1750 33 5 D SOW 8AWG 4C 1 0 Fonte Fonte Fonte Inox SWHD300M6 20 3 60 208 3 1750 18 0 D SOW 12AWG 4C 7 Fonte Fonte Fonte Inox SWH500M2 20 5 60 230 1 1750 40 0 D SOW 6AWG 4C 1...

Page 32: ...UR 6206 Pompes d gouts Mod les SWH300 SWH500 SWHD300 Specifi cations et Performance Levage total pieds 0 15 20 30 40 53 GPM 370 320 292 225 130 0 Levage total pieds 0 15 20 30 40 49 GPM 325 280 245 20...

Page 33: ...e La tuyauterie de d charge doit tre le plus courte possible et dimensionn e ne plus petit que le d charge de la pompe Ne r duisez pas la taille du tuyau de d charge inf rieur celui qui est pr vu sur...

Page 34: ...branch e abaiss e dans le bassin ou le puisard v rifiez le syst me en remplissant de liquide et laissant la pompe fonctionner sur tout son cycle de pompage Le temps n cessaire pour vider le syst me ou...

Page 35: ...nt seulement De la m me mani re remplacez le palier inf rieur sur l arbre de rotor Bo tier d Etanch it Graissez et mettez l anneau d O dans la rainure de la plaque d tanch it Placez la plaque d tanch...

Page 36: ...ent souhaitable d installer ces pompes sans le syst me du rai sauf sur les syst mes emball s d OEM sp ciaux Les clapets doivent toujours tre install s avec des vannes d arr t Cela permet de faciliter...

Page 37: ...trous d entr e dans la base de la pompe sont bouch s Retirez la pompe et nettoyez les ouvertures La distance de pompage vertical est trop lev R duisez la distance ou modifiez les raccords de d charge...

Page 38: ...38 Pompes d gouts Mod les SWH300 et SWH500 S ries Pi ces GROUPEDEPI CESD EXTR MIT HUMIDE GROUPE DE PI CES DE MOTEUR...

Page 39: ...R 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 11 RONDELLE 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 1 12...

Page 40: ...40 Pompes d gouts Mod les SWHD300 SWHD500 Series Pi ces WET END PARTS GROU GROUPEDEPI CESD EXTR MIT HUMIDE GROUPE DE PI CES DE MOTEUR...

Page 41: ...1SWD318 091SWD318 091SWD318 1 19 JOINT 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 20 ENSEMBLE ROTOR 091SWD320 091SWD320 091SWD320 091SWD320 0...

Page 42: ...1899 Cottage Street Ashland Ohio 44805 T l phone 855 281 6830 Fax 877 326 1994 ashlandpump com P U M P H o n n t e P r o f e s s i o n n e l F i a b l e AP SWH300 500 SWHD300 500 OM 03 2018...

Reviews: