DANGER

 

Before installation, read the following instructions care-

fully. Failure to follow instruction and safety information 

could cause serious bodily injury, death and/or property 

damage. Each Ashland Pump is individually factory tested 

to ensure proper performance. Closely following these 

instructions will eliminate potential operating problems 

assuring years of trouble-free service.

Most accidents can be avoided by using common sense.
IMPORTANT - Ashland Pump is not responsible for 

losses, injury or death resulting from failure to observe 

these safety precautions, misuse, abuse or misapplica-

tion of pumps or equipment.
 

 

All returned products must  

 

 

 

be cleaned, sanitized, or    

 

 

decontaminated prior to shipment, to  

 

 

insure employees will not be exposed to  

 

 

health hazards in handling said materials.  

 

 

All applicable laws and regulations shall apply.

   

Bronze/brass fitted pumps may    

   

contain lead levels higher than con-

sidered safe for potable water systems. Government 

agencies have determined that leaded copper alloys 

should not be used in potable water applications. 

   

Installation, wiring, and junction 

   

connections must be in accord-   

ance with the National Electric Code and all applicable 

state and local codes. Requirements may vary depend-

ing on usage and location.

 

   

Installation and servicing is to be    

   

conducted by qualified personnel only.

 

 

Rotating machinery, amputation   

 

 

or severe lacerations can result.   

 

Keep clear of suction and discharge  

 

 

openings. DO NOT insert fingers into pump  

 

with power connected. 

 

 

Always wear eye protection when  

 

 

working on pumps. Do not wear loose 

clothing that may become entangled in moving parts. 
 

 

Pumps build up heat and    

 

 

 

pressure during operation.  

Allow time for pumps to cool before handling or ser-

vicing. 

 

 

Hazardous Voltage can shock,    

 

 

burn or cause death. 

This pump is

  

 not 

intended for use in swimming pools or   

 

water installations where human contact with  

 

pumped fluid is possible. 

 

 

Risk of electrical shock. To  

 

 

 

reduce risk of electrical shock,    

 

always disconnect pump from source  

 

 

before handling.

 Lock out power & tag.

 

 

Sewage Pumps

Model: SWH300/SWH500 & SWHD300/SWHD500

General Safety Information

 

WARNING

 

 

Do Not use these pumps in water  

 

over 145°F. Do not exceed manu-

factures recommended maximum performance, as this 

could cause the motor to overheat.

WARNING

 

   

WARNING

 

WARNING

 

WARNING

 

DANGER

 

DANGER

 

DANGER

 

  

These pumps are NOT to be  

 

 

 

installed in locations classified  

 

 

as hazardous in accordance with the   

 

 

National Electric Code, ANSI/NFPA 70.

WARNING

 

 

Sump and sewage pumps often    

 

handle materials which could cause 

illness or disease. Wear adequate protective clothing 

when working on a used pump or piping. Never enter 

a basin after it has been used.

WARNING

 

 

Do not introduce into any sewer,  

 

either directly, or through a kitchen 

waste disposal unit or toilet: Seafood Shells, Aquarium 

Gravel, Cat Litter, Plastic Objects, Sanitary Napkins or 

Tampons, Diapers, Rags, Disposable Wipes or Cloth, 

Medications, Flammable Material, Oil or Grease, 

Strong Chemicals, Gasoline. 

DANGER

 

DANGER

 

 

 

Do not lift, carry or hang pump by  

 

 

the electrical cables. Damage to    

 

the electrical cables can cause shock, burns or  

 

death. Never handle connected power cords  

 

with wet hands. Use appropriate lifting device.

DANGER

 

  

Failure to permanently ground the  

 

 

pump, motor and controls before   

 

connecting to power can cause shock, burns  

 

or death.

DANGER

 

 

Make sure lifting handles are securely  

 

fastened each time before lifting.

CAUTION

 

•   Operation against a closed discharge valve will cause

 

premature bearing and seal failure on any pump.  

•   Any wiring of pumps should be performed by a  

 

 

qualified electrician.

•  Cable should be protected at all times to avoid  

 

 

punctures, cuts, bruises, and abrasions-inspect  

 

 

frequently.

•  Never handle connected power cords with wet hands.
•   Never let cords or plugs lie in water outside the sump   

 

pit.

•   These pumps are offered in a three phase and single  

 

phase wiring configuration. Voltages will vary

 

according to the application and can be seen in the   

 

tables in this manual.

 

Summary of Contents for SWH300

Page 1: ...hin one year be returned to us with transportation charges prepaid and proved to be defective The above limited warranty takes the place of all other warranties express or implied and correction of su...

Page 2: ...h pumped fluid is possible Risk of electrical shock To reduce risk of electrical shock always disconnect pump from source before handling Lock out power tag Sewage Pumps Model SWH300 SWH500 SWHD300 SW...

Page 3: ...D SOW 8AWG 4C 1 0 Cast Iron Cast Iron Cast Iron SS SWHD300M6 20 3 60 208 3 1750 18 0 D SOW 12AWG 4C 7 Cast Iron Cast Iron Cast Iron SS SWH500M2 20 5 60 230 1 1750 40 0 D SOW 6AWG 4C 1 2 Cast Iron Cas...

Page 4: ...GALLONS PER MINUTE SWH300 SWHD300 PERFORMANCE HEAD FEET 70 60 50 40 30 20 10 0 0 50 100 150 200 250 300 350 400 450 GALLONS PER MINUTE Description To pump domestic commercial and light industrial sew...

Page 5: ...se assembly to the pump Discharge piping should be as short as possible and sized no smaller than the pump discharge Do not reduce the discharge pipe size below that which is provided on the pump Both...

Page 6: ...f oil is found to be clean and uncontaminated measuring above 15 KV breakdown refill the housing If oil is found to be dirty or contaminated or measures below 15 KV breakdown the pump must be carefull...

Page 7: ...d the rotor and press the upper bearing on the rotor shaft applying force to the inner race of the bearing only In the same manner replace lower bearing 49 onto rotor shaft Seal Plate Lubricate and se...

Page 8: ...to cool to room temperature Installing Pump in Sump These pumps are usually installed in concrete or fiberglass basins with the lift out rail system Figure 3 shows pump mounted on the rail system Inst...

Page 9: ...and stop several times by plugging and unplugging cord Check for clogged vent hole in pump case Inlet holes in pump base are clogged Remove pump and clean the openings Vertical pumping distance is to...

Page 10: ...10 Sewage Pumps Model SWH300 SWH500 Series Parts MOTOR PARTS GROUP WET END PARTS GROUP...

Page 11: ...091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 11 WASHER 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 1 12 CONDUIT BUSHING 091SW3014 091SW3014 091SW3014 091SW3...

Page 12: ...12 Sewage Pumps Model SWHD300 SWHD500 Series Parts WET END PARTS GROU MOTOR PARTS GROUP WET END PARTS GROUP...

Page 13: ...SWD318 091SWD318 091SWD318 1 19 BEARING 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 20 ROTOR ASSY 091SWD320 091SWD320 091SWD320 091SWD320 091S...

Page 14: ...14 1899 Cottage Street Ashland Ohio 44805 Telephone 855 281 6830 Fax 877 326 1994 ashlandpump com P U M P H o n e s t P r o f e s s i o n a l D e p e n d a b l e AP SWH300 500 SWHD300 500 OM 03 2018...

Page 15: ...ecci n de dichos defectos por sustituci n o reparaci n debe constituir el cumplimiento de todas las obligacciones bajo los t rminos de la garant a cual EXCLUYE espec ficamente cualquier da o incidenta...

Page 16: ...de agua potable Las instalaciones cableado y conex iones de empalmes deben realizarse en concordancia con el C digo de Electricidad Nacional y con todos los c digos estatales y locales pertinentes Los...

Page 17: ...08 1 1750 33 5 D SOW 8AWG 4C 1 0 Hierro Fundido Hierro Fundido Hierro Fundido Acero SWHD300M6 20 3 60 208 3 1750 18 0 D SOW 12AWG 4C 7 Hierro Fundido Hierro Fundido Hierro Fundido Acero SWH500M2 20 5...

Page 18: ...6206 Bombas de Agua Residual Modelo SWH300 SWH500 SWHD300 SWHD500 Especificaciones y Funcionamiento Total Elevar pulgada 0 15 20 30 40 53 GPM 370 320 292 225 130 0 Total Elevar pulgada 0 15 20 30 40...

Page 19: ...la bomba La tuber a de descarga debe ser lo m s corta posible y de tama o no menor Que la descarga de la bomba No reduzca el tama o de tuber a de descarga Debajo de lo que se proporciona la bomba Se...

Page 20: ...encuentra el aceite por limpiar medici n por encima de 15 kv Desglose llene el c rter haga Las siguientes pruebas de presi n Si se encuentra el aceite sucio o contaminado medici n por encima De 15 kv...

Page 21: ...ando fuerza para la carrera interior Del cojinete solamente De la misma manera reemplace el cojinete inferior En el eje del rotor Placa de Sello Lubrique y ponga el o anillo en la parte inferior de la...

Page 22: ...s bombas sin el sistema ferroviario excepto en sistemas envasados especial de o e m deben instalar las v lvulas de retenci n siempre juntas con v lvulas de cierre Esto permite un servicio m s F cil y...

Page 23: ...rada en la carcasa de la bomba est n obstruidas Retire la bomba y Limpie las aberturas La distancia vertical de bombeo es demasiado alta Reduzca la distancia o cambie Los accesorios de descarga de la...

Page 24: ...24 Bombas de Agua Residual Modelos SWH300 SWH500 Series Piezas GRUPO DE PIEZAS SUMERGIBLES GRUPO DE PIEZAS DEL MOTOR...

Page 25: ...W3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 11 ARANDELA 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 1 12 CASQU...

Page 26: ...26 Bombas de Agua Residual Modelos SWHD300 SWHD500 Series Piezas WET END PARTS GRO GRUPO DE PIEZAS SUMERGIBLES GRUPO DE PIEZAS DEL MOTOR...

Page 27: ...091SWD318 091SWD318 091SWD318 1 19 COJINETE 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 20 EL CONJUNTO DEL ROTOR 091SWD320 091SWD320 091SWD32...

Page 28: ...1899 Cottage Street Ashland Ohio 44805 Telefono 855 281 6830 Fax 877 326 1994 ashlandpump com B O M B A H o n e s t o P r o f e s i o n a l C o n f i a b l e 28 AP SWH300 500 SWHD300 500 OM 03 2018...

Page 29: ...stallation ou 18 mois compter de la date de fabrication selon la premi re ventualit L obligation sous cette garantie est limit la r paration ou au rem placement de toute partie de celle ci qui sont mo...

Page 30: ...la source d alimentation avant de les manipuler Verrouiller l alimentation tag Le puisard et les pompes d eaux us es manipulent souvent des mat riaux qui pourraient causer une maladie ou d une maladi...

Page 31: ...x SWHD300M5 20 3 60 208 1 1750 33 5 D SOW 8AWG 4C 1 0 Fonte Fonte Fonte Inox SWHD300M6 20 3 60 208 3 1750 18 0 D SOW 12AWG 4C 7 Fonte Fonte Fonte Inox SWH500M2 20 5 60 230 1 1750 40 0 D SOW 6AWG 4C 1...

Page 32: ...UR 6206 Pompes d gouts Mod les SWH300 SWH500 SWHD300 Specifi cations et Performance Levage total pieds 0 15 20 30 40 53 GPM 370 320 292 225 130 0 Levage total pieds 0 15 20 30 40 49 GPM 325 280 245 20...

Page 33: ...e La tuyauterie de d charge doit tre le plus courte possible et dimensionn e ne plus petit que le d charge de la pompe Ne r duisez pas la taille du tuyau de d charge inf rieur celui qui est pr vu sur...

Page 34: ...branch e abaiss e dans le bassin ou le puisard v rifiez le syst me en remplissant de liquide et laissant la pompe fonctionner sur tout son cycle de pompage Le temps n cessaire pour vider le syst me ou...

Page 35: ...nt seulement De la m me mani re remplacez le palier inf rieur sur l arbre de rotor Bo tier d Etanch it Graissez et mettez l anneau d O dans la rainure de la plaque d tanch it Placez la plaque d tanch...

Page 36: ...ent souhaitable d installer ces pompes sans le syst me du rai sauf sur les syst mes emball s d OEM sp ciaux Les clapets doivent toujours tre install s avec des vannes d arr t Cela permet de faciliter...

Page 37: ...trous d entr e dans la base de la pompe sont bouch s Retirez la pompe et nettoyez les ouvertures La distance de pompage vertical est trop lev R duisez la distance ou modifiez les raccords de d charge...

Page 38: ...38 Pompes d gouts Mod les SWH300 et SWH500 S ries Pi ces GROUPEDEPI CESD EXTR MIT HUMIDE GROUPE DE PI CES DE MOTEUR...

Page 39: ...R 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 11 RONDELLE 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 1 12...

Page 40: ...40 Pompes d gouts Mod les SWHD300 SWHD500 Series Pi ces WET END PARTS GROU GROUPEDEPI CESD EXTR MIT HUMIDE GROUPE DE PI CES DE MOTEUR...

Page 41: ...1SWD318 091SWD318 091SWD318 1 19 JOINT 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 20 ENSEMBLE ROTOR 091SWD320 091SWD320 091SWD320 091SWD320 0...

Page 42: ...1899 Cottage Street Ashland Ohio 44805 T l phone 855 281 6830 Fax 877 326 1994 ashlandpump com P U M P H o n n t e P r o f e s s i o n n e l F i a b l e AP SWH300 500 SWHD300 500 OM 03 2018...

Reviews: