Sewage Pumps

Model: SWH300/SWH500 & SWHD300/SWHD500

Receiving and Installation

Receiving Inspection

Upon receiving the pump, it should be inspected for 

damage or shortages. If damage has occurred, file a claim 

immediately with the company that delivered the pump. 

If the manual is removed from the packaging, do not lose 

or misplace.

 

Storage

Any product that is stored for a period longer than six (6) 

months from the date of purchase should be bench

tested prior to installation. A bench test consists of, 

checking the impeller to assure it is free turning and a run

test to assure the motor (and switch if provided) operate 

properly. Do not pump out of liquid. 

 

IMPORTANT! A clearance under the

 

pump for entrance of sewage solids 

must be a minimum of 2 inches to a maximum of 3.5 

inches.

Submergence

The pump should always be operated in the submerged 

condition. The minimum sump liquid level should never 

be less than above the pump’s motor (see fig. 1), unless 

very briefly.

Installation

  

The sump or basin shall be sealed and vented in accor-

dance with local plumbing codes. This pump is designed 

to pump domestic wastewater, nonexplosive and non-

corrosive liquids and shall NOT be installed in locations 

classified as hazardous in accordance with the

National Electrical Code (NEC) ANSI/ NFPA 70 or Cana-

dian Electric Code  

(CEC). The pump  

should never be 

installed in a 

trench, ditch, 

or hole with  

a dirt bottom.

The legs will 

sink into the  

dirt and the  

suction will 

become 

plugged. 

 

 

Discharge Piping

Install discharge piping or hose assembly to the pump. 

Discharge piping should be as short as possible and sized 

no smaller than the pump discharge. Do not reduce the 

discharge pipe size below that which is provided on the 

pump. Both a check valve and a shut-off valve are recom-

mended for each pump. The check valve is used to pre-

vent backflow into the sump. The shut-off valve is used to 

manually stop system flow during pump servicing. Be sure 

the discharge pipe has a 1/8” diameter hole approx. 5” 

from end nearest volute and oriented towards the pump 

body. 

Control Panel

Single phase series sewage pumps DO NOT require a 

control panel, but do require a level control.

 

 

WARNING

 

FIGURE 1

Motor:

 Each motor is provided with heat sensor thermo-

stats attached directly to the motor windings. The

thermostats open if the motor windings see excessive heat 

and, in turn, open the motor contactor in the control panel 

when used, breaking the power to the pump. When the 

motor is stopped due to an overheated condition, it will 

not start until the motor has cooled.

Minimum 

Submergance

Pre-operation

CHECK VOLTAGE AND PHASE

Before operating pump, check to make sure that voltage 

and phase information stamped on the pump’s identifica-

tion plate matches the available power.

CHECK PUMP ROTATION

Before putting pump into service for the first time, the 

motor rotation must be checked. Improper motor rota-

tion can result in poor pump performance and

can damage the motor and/or pump.

IDENTIFICATION PLATE

Note the numbers on the pumps identification plate and 

record in this manual for future reference.

Electrical Connections

 

Turn circuit breaker off before

 

plugging or unplugging the

 

switch and/or pump.

 

 

Always rely upon a Certified Electrician for installation.

Summary of Contents for SWH300

Page 1: ...hin one year be returned to us with transportation charges prepaid and proved to be defective The above limited warranty takes the place of all other warranties express or implied and correction of su...

Page 2: ...h pumped fluid is possible Risk of electrical shock To reduce risk of electrical shock always disconnect pump from source before handling Lock out power tag Sewage Pumps Model SWH300 SWH500 SWHD300 SW...

Page 3: ...D SOW 8AWG 4C 1 0 Cast Iron Cast Iron Cast Iron SS SWHD300M6 20 3 60 208 3 1750 18 0 D SOW 12AWG 4C 7 Cast Iron Cast Iron Cast Iron SS SWH500M2 20 5 60 230 1 1750 40 0 D SOW 6AWG 4C 1 2 Cast Iron Cas...

Page 4: ...GALLONS PER MINUTE SWH300 SWHD300 PERFORMANCE HEAD FEET 70 60 50 40 30 20 10 0 0 50 100 150 200 250 300 350 400 450 GALLONS PER MINUTE Description To pump domestic commercial and light industrial sew...

Page 5: ...se assembly to the pump Discharge piping should be as short as possible and sized no smaller than the pump discharge Do not reduce the discharge pipe size below that which is provided on the pump Both...

Page 6: ...f oil is found to be clean and uncontaminated measuring above 15 KV breakdown refill the housing If oil is found to be dirty or contaminated or measures below 15 KV breakdown the pump must be carefull...

Page 7: ...d the rotor and press the upper bearing on the rotor shaft applying force to the inner race of the bearing only In the same manner replace lower bearing 49 onto rotor shaft Seal Plate Lubricate and se...

Page 8: ...to cool to room temperature Installing Pump in Sump These pumps are usually installed in concrete or fiberglass basins with the lift out rail system Figure 3 shows pump mounted on the rail system Inst...

Page 9: ...and stop several times by plugging and unplugging cord Check for clogged vent hole in pump case Inlet holes in pump base are clogged Remove pump and clean the openings Vertical pumping distance is to...

Page 10: ...10 Sewage Pumps Model SWH300 SWH500 Series Parts MOTOR PARTS GROUP WET END PARTS GROUP...

Page 11: ...091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 11 WASHER 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 1 12 CONDUIT BUSHING 091SW3014 091SW3014 091SW3014 091SW3...

Page 12: ...12 Sewage Pumps Model SWHD300 SWHD500 Series Parts WET END PARTS GROU MOTOR PARTS GROUP WET END PARTS GROUP...

Page 13: ...SWD318 091SWD318 091SWD318 1 19 BEARING 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 20 ROTOR ASSY 091SWD320 091SWD320 091SWD320 091SWD320 091S...

Page 14: ...14 1899 Cottage Street Ashland Ohio 44805 Telephone 855 281 6830 Fax 877 326 1994 ashlandpump com P U M P H o n e s t P r o f e s s i o n a l D e p e n d a b l e AP SWH300 500 SWHD300 500 OM 03 2018...

Page 15: ...ecci n de dichos defectos por sustituci n o reparaci n debe constituir el cumplimiento de todas las obligacciones bajo los t rminos de la garant a cual EXCLUYE espec ficamente cualquier da o incidenta...

Page 16: ...de agua potable Las instalaciones cableado y conex iones de empalmes deben realizarse en concordancia con el C digo de Electricidad Nacional y con todos los c digos estatales y locales pertinentes Los...

Page 17: ...08 1 1750 33 5 D SOW 8AWG 4C 1 0 Hierro Fundido Hierro Fundido Hierro Fundido Acero SWHD300M6 20 3 60 208 3 1750 18 0 D SOW 12AWG 4C 7 Hierro Fundido Hierro Fundido Hierro Fundido Acero SWH500M2 20 5...

Page 18: ...6206 Bombas de Agua Residual Modelo SWH300 SWH500 SWHD300 SWHD500 Especificaciones y Funcionamiento Total Elevar pulgada 0 15 20 30 40 53 GPM 370 320 292 225 130 0 Total Elevar pulgada 0 15 20 30 40...

Page 19: ...la bomba La tuber a de descarga debe ser lo m s corta posible y de tama o no menor Que la descarga de la bomba No reduzca el tama o de tuber a de descarga Debajo de lo que se proporciona la bomba Se...

Page 20: ...encuentra el aceite por limpiar medici n por encima de 15 kv Desglose llene el c rter haga Las siguientes pruebas de presi n Si se encuentra el aceite sucio o contaminado medici n por encima De 15 kv...

Page 21: ...ando fuerza para la carrera interior Del cojinete solamente De la misma manera reemplace el cojinete inferior En el eje del rotor Placa de Sello Lubrique y ponga el o anillo en la parte inferior de la...

Page 22: ...s bombas sin el sistema ferroviario excepto en sistemas envasados especial de o e m deben instalar las v lvulas de retenci n siempre juntas con v lvulas de cierre Esto permite un servicio m s F cil y...

Page 23: ...rada en la carcasa de la bomba est n obstruidas Retire la bomba y Limpie las aberturas La distancia vertical de bombeo es demasiado alta Reduzca la distancia o cambie Los accesorios de descarga de la...

Page 24: ...24 Bombas de Agua Residual Modelos SWH300 SWH500 Series Piezas GRUPO DE PIEZAS SUMERGIBLES GRUPO DE PIEZAS DEL MOTOR...

Page 25: ...W3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 11 ARANDELA 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 1 12 CASQU...

Page 26: ...26 Bombas de Agua Residual Modelos SWHD300 SWHD500 Series Piezas WET END PARTS GRO GRUPO DE PIEZAS SUMERGIBLES GRUPO DE PIEZAS DEL MOTOR...

Page 27: ...091SWD318 091SWD318 091SWD318 1 19 COJINETE 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 20 EL CONJUNTO DEL ROTOR 091SWD320 091SWD320 091SWD32...

Page 28: ...1899 Cottage Street Ashland Ohio 44805 Telefono 855 281 6830 Fax 877 326 1994 ashlandpump com B O M B A H o n e s t o P r o f e s i o n a l C o n f i a b l e 28 AP SWH300 500 SWHD300 500 OM 03 2018...

Page 29: ...stallation ou 18 mois compter de la date de fabrication selon la premi re ventualit L obligation sous cette garantie est limit la r paration ou au rem placement de toute partie de celle ci qui sont mo...

Page 30: ...la source d alimentation avant de les manipuler Verrouiller l alimentation tag Le puisard et les pompes d eaux us es manipulent souvent des mat riaux qui pourraient causer une maladie ou d une maladi...

Page 31: ...x SWHD300M5 20 3 60 208 1 1750 33 5 D SOW 8AWG 4C 1 0 Fonte Fonte Fonte Inox SWHD300M6 20 3 60 208 3 1750 18 0 D SOW 12AWG 4C 7 Fonte Fonte Fonte Inox SWH500M2 20 5 60 230 1 1750 40 0 D SOW 6AWG 4C 1...

Page 32: ...UR 6206 Pompes d gouts Mod les SWH300 SWH500 SWHD300 Specifi cations et Performance Levage total pieds 0 15 20 30 40 53 GPM 370 320 292 225 130 0 Levage total pieds 0 15 20 30 40 49 GPM 325 280 245 20...

Page 33: ...e La tuyauterie de d charge doit tre le plus courte possible et dimensionn e ne plus petit que le d charge de la pompe Ne r duisez pas la taille du tuyau de d charge inf rieur celui qui est pr vu sur...

Page 34: ...branch e abaiss e dans le bassin ou le puisard v rifiez le syst me en remplissant de liquide et laissant la pompe fonctionner sur tout son cycle de pompage Le temps n cessaire pour vider le syst me ou...

Page 35: ...nt seulement De la m me mani re remplacez le palier inf rieur sur l arbre de rotor Bo tier d Etanch it Graissez et mettez l anneau d O dans la rainure de la plaque d tanch it Placez la plaque d tanch...

Page 36: ...ent souhaitable d installer ces pompes sans le syst me du rai sauf sur les syst mes emball s d OEM sp ciaux Les clapets doivent toujours tre install s avec des vannes d arr t Cela permet de faciliter...

Page 37: ...trous d entr e dans la base de la pompe sont bouch s Retirez la pompe et nettoyez les ouvertures La distance de pompage vertical est trop lev R duisez la distance ou modifiez les raccords de d charge...

Page 38: ...38 Pompes d gouts Mod les SWH300 et SWH500 S ries Pi ces GROUPEDEPI CESD EXTR MIT HUMIDE GROUPE DE PI CES DE MOTEUR...

Page 39: ...R 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 11 RONDELLE 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 091SW3013 1 12...

Page 40: ...40 Pompes d gouts Mod les SWHD300 SWHD500 Series Pi ces WET END PARTS GROU GROUPEDEPI CESD EXTR MIT HUMIDE GROUPE DE PI CES DE MOTEUR...

Page 41: ...1SWD318 091SWD318 091SWD318 1 19 JOINT 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 091SW3011 1 20 ENSEMBLE ROTOR 091SWD320 091SWD320 091SWD320 091SWD320 0...

Page 42: ...1899 Cottage Street Ashland Ohio 44805 T l phone 855 281 6830 Fax 877 326 1994 ashlandpump com P U M P H o n n t e P r o f e s s i o n n e l F i a b l e AP SWH300 500 SWHD300 500 OM 03 2018...

Reviews: