RUN
CAPACITOR
START
CAPACITOR
5
2
1
B
B
W
W
R
G
RELAY
TERMINAL
CONNECTOR
R
RUN CAPACITOR
R
START
CAPACITOR
RELAY
MAIN
MOTOR
START
IRIN CONNECTIONS
PO E R
COR
FIGURE 6
POWER
CORD
11
Grinder Pumps
Model: AGP200 Series
Wiring Diagram
WIRING CONNECTIONS
1. All electrical wiring must be in accordance with local
code and only qualified electricians should make the
installations.
2. Three phase pumps - instructions for wiring to control
panel will be included with control panel.
All wires should be checked for shorts to ground with an
ohmmeter or megger after the connections are made. This
is IMPORTANT, as one grounded wire can cause failure of
the pump, control panel or personal injury.
208/230 VOLT, I PHASE 60HZ
WITH CAPACITORS IN PANEL
START CAPACITORS
RUN CAPACITOR
RELAY
G
R
1
2
5
OL
T3
T2
T1
BR
W
M
BW
CB
L1
S
R
L2
FIGURE 5
SINGLE PHASE
208/230 VOLT, 1 PHASE 60HZ
WITH CAPACITORS IN PUMP
WARNING
208/230