ASG DTT-10 User Manual Download Page 16

ASG, Division of Jergens, Inc.  

15700

 S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: [email protected] | www.asg-jergens.com

Page 16 of 23

Main Menu (Continued)

Delete All

Upload All

This is used to delete all saved records.  
•  To access the Delete All menu, press and hold the 

MENU/ESC

 key to access the 

main menu. Use the 

UP

 or 

DOWN

 arrow keys to move the cursor to 

MEMORY

 

and press 

ENTER

.  Use the 

UP

 or 

DOWN

 arrow keys to move the cursor to 

DELETE ALL 

and press 

ENTER.

•  Press 

ESC

 key to return to the memory menu page

•  Press the 

UP

 or 

DOWN

 arrow keys to select 

NO

 or 

YES

.  If you select 

NO

 and 

press the 

ENTER

 key, the meter will return to the memory menu page.  If you 

select 

YES

 and press the 

ENTER

 key, the meter will delete all saved records and 

return to the memory menu page.

This is used to transfer memory to a computer.
•  To transfer memory to a computer, press and hold the 

MENU/ESC

 key to 

access the main menu. Use the 

UP

 or 

DOWN

 arrow keys to move the cursor 

to 

MEMORY

 and press 

ENTER

.  Use the 

UP

 or 

DOWN

 arrow keys to move the 

cursor to 

UPLOAD ALL 

and press 

ENTER.

•  The display will show the transfer memory menu page
•  Press the 

ESC

 key to return to the memory menu page

DTT Series Digital Torque Testers 

User Manual

Delete Last 

This is used to delete the last saved record.  
•  To access the Delete Last menu, press and hold the 

MENU 

key to access the 

main menu. Use the 

UP

 or 

DOWN

 arrow keys to move the cursor to 

MEMORY

 

and press 

ENTER

.  Use the 

UP

 or 

DOWN

 arrow keys to move the cursor to 

DELETE LAST 

and press 

ENTER.

•  The display will show 

DELETE LAST

 menu page

•  Press the 

ESC

 key to return to the memory menu page

•  Press the 

UP

 and 

DOWN

 arrow keys to select 

NO

 or 

YES

.  If you select 

NO

 and 

press the 

ENTER

 key, the monitor will return to the memory menu page.  If you 

select 

YES

 and press the 

ENTER

 key, the meter will delete last saved record and 

return to the memory menu page.

Summary of Contents for DTT-10

Page 1: ...H 44110 3898 Phone 888 486 6163 Fax 216 481 4519 Email asginfo asg jergens com Web www asg jergens com Page 1 of 23 2017 Jergens Inc All Rights Reserved Revision Date 04 10 17 DTT Series Digital Torqu...

Page 2: ...own Adapter 7 Usage 8 Procedure for Manual Torque Screwdrivers 8 Procedure for Power Screwdrivers 8 Battery Indicator 9 Basic Function 9 Display of Clockwise Counter Clockwise 9 Zeroing the Tester 10...

Page 3: ...asg jergens com Page 3 of 23 Table of Contents Continued DTT Series Digital Torque Testers User Manual Statistics 17 Calibration 17 Transducer State 17 Date and Time 18 About 18 Software 19 TorqueLink...

Page 4: ...disclaimed and excluded from this transaction and shall not apply to the goods sold hereunder The ASG DTT meter is an electronic instrument and should be treated with the same care given any sensitive...

Page 5: ...to USB RS 232 Key Button 4 Buttons Unit of Measure 6 7 User Selectable Torque Units Depending on Model Mode of Measure 3 Modes Track Peak and First Peak Display Digits 6 Digits Maximum Special Functio...

Page 6: ...g Color lbf in N m 66620 Adapter w Spring 4mm HIOS 0 25 2 0 0 03 0 23 Black CP66612 Adapter 1 4 Hex N A N A N A CP66614 Spring N A 1 3 5 0 0 15 0 56 Yellow CP66616 Spring N A 4 5 26 0 0 51 2 9 Black I...

Page 7: ...5 26 0 0 51 2 94 66618 1 4 Hex 25 0 80 0 2 8 9 03 66639 5 mm Hex 25 0 80 0 2 8 9 03 66634 3 8 Hex 50 0 200 0 5 65 22 6 66642 3 8 Hex 50 0 500 0 5 65 56 5 Below is a list of all rundown adapters ASG o...

Page 8: ...ings are consistent The proper reading may be an average of several readings Procedure for Power Screwdrivers Put the appropriate rundown adapter into the unit s female 3 8 square socket This is also...

Page 9: ...ery Empty message will be displayed and the tester will power down automatically When battery charger is connected and battery is charging the plug icon will blink Charging time is about 2 3 hours for...

Page 10: ...ressed it will select the next available unit until the tester returns to its original setting The DTT automatically converts readings as new units of measure are selected NOTE All units may not be di...

Page 11: ...unction Continued Saved Reading to Memory Output Signal Command Action Pressing PRINT key If current mode is track mode send live reading value with unit If current mode is first peak torque mode send...

Page 12: ...the RESET key since the peak value will automatically reset This feature works in peak mode only If this feature is activated the icon AR will display on main display To access the Auto Reset menu pr...

Page 13: ...DOWN arrow keys to move the cursor to SETTING and press ENTER Use the UP or DOWN arrow keys to move the cursor to PASS FAIL and press ENTER Press and hold the DOWN arrow key to toggle between the uppe...

Page 14: ...se torque is applied the tester will reset the reading and the tester will be ready to take new reading If COUNTER CLOCKWISE is selected in this mode the tester will only record counter clockwise torq...

Page 15: ...e Factory Reset menu press and hold the MENU key to access the main menu Use the UP or DOWN arrow keys to move the cursor to SETTING and press ENTER Use the UP or DOWN arrow keys to move the cursor to...

Page 16: ...r To transfer memory to a computer press and hold the MENU ESC key to access the main menu Use the UP or DOWN arrow keys to move the cursor to MEMORY and press ENTER Use the UP or DOWN arrow keys to m...

Page 17: ...contact ASG to arrange a recalibration of your tester If the offset is greater than 10 please contact ASG to arrange for repair or replacement These values are given only as an indicator the need for...

Page 18: ...and hold these keys PREV and NEXT to toggle between the category Press the ENTER key to save information Press the ESC key to return to the main menu page This shows the information regarding your tes...

Page 19: ...files to the table Save For data storage in the form of torque file tl Print Command to print directly to the printer Export to Excel Save and export the data to Excel spreadsheet Click To Connect Co...

Page 20: ...User Manual No Shows the sequence of data Mode Indicates the mode of operation when the reading was taken Direction Indicates the direction of the force CW represents the clockwise rotation CCW repre...

Page 21: ...Shows the highest value in the table Min Shows the smallest value in the table Mean Values on average SD Values of the standard deviation COV Coefficient of variation PASS Shows number of torque readi...

Page 22: ...Torque Testers User Manual 1 Plug the USB cable into the DTT meter and the PC 2 Turn on the DTT meter 3 On the menu bar in Torque Link 2 4 select Click to Connect TorqueLink will automatically find an...

Page 23: ...TT meter and the PC 2 Turn on the DTT meter 3 On the menu bar in Torque Link 2 4 select the Click to Connect TorqueLink will automatically find and connect with the DTT meter 4 When DTT is in Peak or...

Reviews: