Asema M2 User Manual Download Page 4

Safety

Please read this before proceeding and follow the safety precautions below when installing and operating

the system.

Retain and follow all product safety and operating instructions.

Observe all warnings in the operating instructions on the product.

Operate your appliances responsibly, especially when controlling them with remote controls or over the Inter-
net. Remote control of appliances in an Asema system is disabled by default to prevent accidental damage.
Enable remote control only on devices where you can be certain damage cannot occur due to for instance
heat, fire, smoke or water you do not notice while not present.

Always use an authorized and qualified electrician when installing products that involve rewiring electrical
connections, changes to the distribution box, or opening wall sockets or other components embedded into
walls, floors, or ceilings. Live cables can only be accessed by a qualified electrician.

Do  not  force  or  bend  the  cables  at  any  point  during  installation.  Do  not  drop,  throw  or  try  to  bend  the
product. If you are worried or have any concerns about the installation, please contact a qualified electrician
immediately.

Slots and openings in the product are provided for ventilation. These openings must not be blocked or covered.
Loss of ventilation may cause the product to overheat.

If you notice anything unusual about the product such as loose wires, exposed cabling, burn marks, holes in
the insulating materials or damage to the product, stop immediately.

When a power supply unit is included with the product only use the designated power supply unit. Other
usage may be dangerous and will invalidate any approval given to this product.

Unless specifically indicated otherwise, the product is designed to operate in room temperature under dry
conditions. Keep the device dry and away from excessive moisture, water or any liquid as it may cause a
short circuit. Keep the device away from extreme temperatures.

If this product is equipped with a USB port for connecting to a power or a computer, note that connecting
to improperly grounded equipment can result in an electric shock to your device. Be sure your computer is
properly grounded (earthed) before connecting this product to a computer.

Do not use this product in gas stations, fuel depots, chemical plants or where blasting operations are in
progress, or in potentially explosive atmospheres such as fueling areas, fuel storehouses, below deck on
boats, chemical plants, fuel or chemical transfer or storage facilities, and areas where the air contains chemi-
cals or particles, such as grain, dust, or metal powders. Please be aware that sparks in such areas could cause
an explosion or fire resulting in bodily injury or even death.

This product may cause medical equipment to malfunction. The use of this device is forbidden in most hos-
pitals and medical clinics.

There is no need to open the product. YOUR WARRANTY IS INVALIDATED IF YOU DISASSEMBLE OR AT-
TEMPT TO DISASSEMBLE THE DEVICE.

Summary of Contents for M2

Page 1: ...English Asema M2 User Manual ...

Page 2: ...on may be reproduced published stored in an electronic database or transmitted in any form or by any means electronic mechanical recording or otherwise for any purpose without the prior written permission from Asema Electronics Ltd Asema E is a registered trademark of Asema Electronics Ltd ...

Page 3: ...cating the leads and attaching the clamps 2 1 2 Connecting to power 2 2 Pairing and communicating with Asema E 3 2 1 Pairing the meter 3 2 2 Test reading with radio quality measurement 3 2 3 Removing the meter 3 2 4 Resetting the meter 4 2 5 Mesh networking 4 3 Troubleshooting 5 ...

Page 4: ...wires exposed cabling burn marks holes in the insulating materials or damage to the product stop immediately When a power supply unit is included with the product only use the designated power supply unit Other usage may be dangerous and will invalidate any approval given to this product Unless specifically indicated otherwise the product is designed to operate in room temperature under dry condit...

Page 5: ...cated by the installation diagram on the device The clamps are attached to the lead only do not attach them to the neutral Note the numbering on the clamps this must match the numbering of the phases to correctly display the power consumption of that phase 1 2 Connecting to power The Asema M2 is powered by 230V power from one of the phases You may freely choose the phase Do not take power from the...

Page 6: ...ems it is recommended to take a test reading from it Enter the Central Meter menu in the Main Setup and press the Test button This will attempt to read the current measured value from the meter You will be shown the radio quality statistics as well as whether the test reading was successful If the test fails 1 Ensure that the Asema M meter is still connected to the mains power and within radio ran...

Page 7: ... M2 the reset button is the gray button in front marked with RESET 2 5 Mesh networking Mesh networking means that Asema controllers and meters with a radio can relay messages auto matically between them and this way extend the range of communication or go around obstacles Thus they work automatically as repeaters of messages for each other Asema S series controllers and Asema M series meters will ...

Page 8: ... meter is properly connected to mains power The ensure there are no inter fering obstacles between the meter and an Asema E and the distance between the two does not exceed 30 meters Check that the meter is not already paired A paired meter no longer sends a beacon and cannot therefore be detected To have the meter send beacon again reset it either from the Asema E in case of a meter paired to tha...

Page 9: ...uch hazardous waste Isolated collection and proper recovery of your electronic and electrical waste equipment at the time of disposal will allow us to help conserving natural resources Moreover proper recycling of the electronic and electrical waste equipment will ensure safety of human health and environment RoHS compliance This product is in compliance with Directive 2002 95 EC of the European P...

Reviews: