EN
8
Ø 1 mm
Ø 6,35 mm
T-part with Inserting
DN50 plug
G1/4” threaded
Pool Chemicals Connection
At this step is necessary to connect the injecting valves of chemicals to the
dosing pump and dosed agent.
Place the injecting valve in the T-joint, blinded with the
DN50 G1/4” threaded
plug #12134.
1.
Cut the PE tube at 90 ° angle to ensure proper fi tting.
•
Use the sharp knife to cut plastic. The cut must be clean and smooth.
2.
Drill the 6 mm hole and the 1 mm hole (air suction) into the canister cap.
Push the PE tube through the cap. Select the tube distance so that the
tube reaches the canister bottom and can be connected to the pump as
straight as possible. A long tube in the canister would bend and produce
air bubbles.
3.
Put a weight on the tube end and dive it in the canister.
4.
Connect the plastic tube from the canister to the left connection of the
peristaltic pump.
5.
Connect the plastic tube to the right connection of the pump and the
injection valve on the other end.
6.
Hand screw the injection valve in the specifi ed mounting hole (see
diagram).
•
The injection valve is installed in G 1/4” thread.
•
Check throughput of the injection valves and tightness of the entire
system.
WARNING:
Only hand tighten. Do not use tongs or any other tools.