Peristaltic pump PP60 pH
PP60 pH automatically regulates the pH value of the pool water, measured
by a standard pH probe. The set pH value is shown on the red LED display.
LED display also serves to set all the necessary parameters. During
operation, the required dose of the reagent is calculated from the measured
value and the dose is then disposed into the pool water. The PP60 pH is
composed of a control unit, a measuring probe, and a dosing pump with a
maximum pump power of 60 ml / min.
Technical information
Power supply
230 V / 50 Hz
Power consumption
20 VA
Fuse
T80 mA
Overvoltage category
II
Protection
IP30
Operating temperature
+5 to +40°C
Weight
2268g
Installation
Wall mounted
Pump power
60 ml / min
Max water pressurey
1 bar
Installation PP60 pH
PP60 pH is to be wall mounted in dry and dust-free environment with
temperature ranging from +5 °C to +40 °C. To mount the device, use the
mounting holes that are accessible after opening the front cover of the
device. To mount the device use screws supplied with the device.
WARNING:
The location temperature should permanently be in the range
from +5 °C to +40 °C.
Direct sunlight, high humidity and dust may lead to damage to PP60 pH.
•
Before installing, ensure that pool water is chemically clean and free
of dirt.
•
The maximum distance of injection valves from peristaltic pump of
PP60 pH must not be greater than 8 m.
•
Vertical distance between PP60 pH and the bottom of containers must
not exceed 2 m.
40 °C
m
ax
.
5 °C
m
in
.
40cm
0cm
40cm
40cm
150cm
40 °C
m
ax
.
5 °C
m
in
.
13,5 cm
40 °C
m
ax
.
5 °C
m
in
.
max 8m
max 2m
WARNING
PP60 pH power supply must be connected together with the power sup-
ply of the circulation pump. Switching off the circulation pump must switch
off the PP60 pH, otherwise inaccurate measurement and incorrect dosing
would occur.