30
ASIN Aqua NET
Item
Maintenance Procedure
Recommendation
pH and Chlor
ine D
osing
Valv
es
Check your valves regularly for
blockages, damaged rubber seals
and the build up of limescale.
Check for damage to the
clear plastic tubes.
In case of very hard water, swop
the clear plastic tube connecting
the pH and chlorine to the valves
every 2 weeks. This prevents
the build up of limescale.
WARNING: Mixing the pH and
chlorine agents is extremely
dangerous. Always wear personal
protective safety equipment,
gloves glasses and mask. After
disconnecting tubes rinse in
clean water before reconnecting.
Change your injection valves
every 2 years for private pool use
or every 1 year for public pools.
# 12005
Chlor
ine and
pH A
gen
t
Regularly check the level.
Chlorine agent decomposes with
time. Replace every 6 months
PH and Chlor
ine
Pumps
Check inside the pumps for
damage. The clear plastic tubes
wear out during operation.
Replace tubes every
12 months. # 12073
Item
Maintenance Procedure
Recommendation
CLF P
robe
Remove your CLF probe from
your ASIN Aqua and clean
off any dust and debris.
Clean your probe with
fresh water and wipe with
a clean soft material.
Check the sensitivity in mV
in CALIBRATION MENU.
If this is at 0,5 mg/l under
10 mV change the electrolyte
or membrane module.
Change the electrolyte
every 6 months. # 12071
Change the membrane module
every 1 years. # 12029
Redo
x P
robe
Remove your Redox probe
from your ASIN Aqua and clean
off any dust and debris.
Clean your probe with
fresh water and wipe with
a clean soft material.
Change your Redox probe
every 1 – 2 years. # 12015
pH P
robe
Remove your pH probe from
your ASIN Aqua and clean
off any dust and debris
Clean your probe with
fresh water and wipe with
a clean soft material.
Change the pH probes
every 1 – 2 years. # 12014