Step 2
Connecting the measuring Water
ASIN Aqua requires connection to the water from your pool. Connect
the supply to your ASIN Aqua after the pump and before the fi lter.
Thread = G 1/4".
For the water connection to your ASIN Aqua, Aseko provides water
valve with a unique Speedfi t connector. To connect, push the clear
plastic tube into the Speedfi t connector. To remove the tube from
the connector, push the collet in, and pull on the tube.
WARNING:
Using pliers or cutters damages
your hose and results in a poor fi tting.
1.
Cut your clear plastic tube at 90 degree
angle to ensure proper fi tting.
Use a sharp knife or razor to cut the tubes cleanly
2.
Connect the water input on the left and the water output
on the right. Make sure the water pressure is not more than 1.5 bar.
3.
The water output from your ASIN Aqua can be connected, on the tubing
before the pump or to the skimmer, the buff er tank or to a drain.
After connecting the water supply, your ASIN Aqua is then set up to take
samples of the water from your pool and analyze them. The analysis allows the
monitoring of chlorine levels and pH levels ensuring your pool hygiene.
WARNING:
Only hand tighten the connections.
Do not use pliers or wrench.
WASTE
WASTE
Water supply
for the probes (IN)
Water outlet from probes (OUT)
Water from the
CLF probe
must led to no pressure.
For example to Buffer
tank, skimmer or waste.
Water from the
REDOX probe
can be
connected before
filtration pump.
*)
Water
supply
*)
Water valve
Thread 1/4”
Tube 6 x 1
Connection
Water and chemical
6 x 1 clear plastic tube
90°
Water valve
Disconnection