asecos UFA.025.030 User Manual Download Page 9

9

EN

Ser

 4

Running time of the filter sensor longer than 54 months.  

Sensor drift and thus safe operation can no longer be guaranteed. The 

sensor must be replaced.

Please contact your responsible specialist dealer 

or to our service hotline 01805 - 92 20 9

F 1

Differential pressure sensor error

Please contact your responsible specialist dealer 

or to our service hotline 01805 - 92 20 9

F 2

Error temperature/humidity sensor

Please contact your responsible specialist dealer 

or to our service hotline 01805 - 92 20 9

F 3

Filter sensor defective

Please contact your responsible specialist dealer 

or to our service hotline 01805 - 92 20 9

F 4

Fan defective (blocked)

Please contact your responsible specialist dealer 

or to our service hotline 01805 - 92 20 9

F 7

Self test error 

Display F7 alternating with the respective error F1 to F4

Please contact your responsible specialist dealer 

or to our service hotline 01805 - 92 20 9

14 ct/called minute from the Deutsche Telekom AG fixed network, from mobile phones a maximum of 42 ct/minute.

6. REPAIRS

ATTENTION 

Repairs are only to be carried out by specialists specifically trained for this. 
Given damage the appliance is to be repaired or replaced by the manufacturer.

7. FUNCTIONAL CHECK • MAINTENANCE • CARE

To ensure safety, the recirculation filter attachment should be serviced at least once a year and its function 

checked by a specialist. At the same time, the built-in filter unit must be replaced at least once a year, and 

immediately when the saturation limit is reached. 

The functionality is checked electronically by the integrated ventilation and filter saturation monitoring, so that 

a function check of the recirculation filter attachment is carried out permanently during operation. The activat-

ed charcoal main filter of the recirculation filter attachment must be replaced with a new filter at short notice 

if the corresponding maintenance indicator (red screen) is shown. The filter can only be replaced by one of 

our trained service technicians and must be requested promptly on the service hotline. Filter replacement by 

asecos service personnel ensures that the contaminated activated carbon is fed into a defined disposal chain. 

7.1.  SENSORS AND MONITORING ELECTRONICS

The UFA contains sensitive sensors and complex monitoring electronics. The device must be designed as a 

“continuous 24/7" and was also designed for this purpose. The sensitive gas sensor system in particular is 

heavily stressed by continuous operation and, according to experience, can deliver unreliable measurement 

results after a certain period of operation (drift) after approx. 40,000 operating hours. 

The UFA can then no longer be used safely (possible monitoring errors). 

In this case, a visual warning is given. In this case, please contact the customer service for replacement of the 

sensor unit.

7.2.  CLEANING

For external cleaning of the recirculating air filter attachment, please use common, mild household cleaners 

and a soft cloth. 

Disconnect your recirculating air filter attachment from the mains by unplugging 

the power cable before cleaning! Make sure that no moisture gets into the inside of the recircu-

lating air filter attachment during cleaning.

CONTACT: 

In the case of defects or complaints about our products (within and also after the warranty period), and for 
requesting safety checks or taking out a service contract, please contact our service hotline on: 
Tel: +44 1785 22 70-90 [email protected]

Summary of Contents for UFA.025.030

Page 1: ...EN EP V 34660 01 05 2022 USER MANUAL Recirculating air filter unit UFA 025 030 XL...

Page 2: ...ting monitoring 4 2 5 Potential free alarm contact 5 3 ERECTION COMMISSIONING 5 3 1 Commissioning 5 3 2 Self test 6 4 DISPLAY AND MENU 6 4 1 Power indicator 6 4 2 Overview of the menu icons 7 4 3 Show...

Page 3: ...ELOPMENT AND MANUFACTURER asecos GmbH Weiherfeldsiedlung 16 18 63584 Gr ndau Germany The type plate with the serial number is located on the outside of the unit s housing 1 4 PURPOSE OF USE The unit i...

Page 4: ...ther materials are to be stored Safe and faultless function is shown by the ventilation and filter monitoring mechanism which is fitted as standard 3 2 ventilator 2 4 VENTILATION SETTING MONITORING Th...

Page 5: ...nternal alarm contact Connector External connection Contact position Normal operation L and 1 are connected Alarm or mains failure L and 2 are connected CAUTION The potential free alarm contact must n...

Page 6: ...begins during which all safety relevant compo nents are checked If there is a fault the unit will not start An error F7 is displayed alternating with the relevant faulty safety element F1 F4 4 DISPLAY...

Page 7: ...y Symbols in the Settings menu and sub items Set contrast Carry out filter change Set air monitoring parameters Replace sensor Exit current display 4 3 SHOW SYSTEM INFORMATION ATTENTION For a simplifi...

Page 8: ...fan has been switched off It is now imperative to change the filter at short notice Main filter and secondary filter change necessary Please contact your specialist dealer or our service hotline 01805...

Page 9: ...toring so that a function check of the recirculation filter attachment is carried out permanently during operation The activat ed charcoal main filter of the recirculation filter attachment must be re...

Page 10: ...DC V 30 30 Potential free alarm contact single phase motor load W 185 185 Potential free alarm contact max switching capacity electromagnetic VA 300 300 Potential free alarm contact max switching capa...

Page 11: ...in undisturbed operation nA non functioning 4 Explosion groups according to EN 60079 0 2019 09 IIB the group has a limiting gap width MESG 0 5 0 9 mm suitable e g for use with ethylene 5 Unit categori...

Page 12: ...Perp tua de Mogoda Barcelona 34 902 300385 34 902 300395 info asecos es asecos bv Veiligheid en milieubescherming Tuinderij 15 NL 2451 GG Leimuiden 31 172 506476 31 172 506541 info asecos nl asecos S...

Reviews: