Running time of the filter sensor longer than 54 months.
Sensor drift and thus safe operation can no longer be guaranteed. The
sensor must be replaced.
Please contact your responsible specialist dealer
or to our service hotline 01805 - 92 20 9
F 1
Differential pressure sensor error
Please contact your responsible specialist dealer
or to our service hotline 01805 - 92 20 9
F 2
Error temperature/humidity sensor
Please contact your responsible specialist dealer
or to our service hotline 01805 - 92 20 9
F 3
Filter sensor defective
Please contact your responsible specialist dealer
or to our service hotline 01805 - 92 20 9
F 4
Fan defective (blocked)
Please contact your responsible specialist dealer
or to our service hotline 01805 - 92 20 9
F 7
Self test error
Display F7 alternating with the respective error F1 to F4
Please contact your responsible specialist dealer
or to our service hotline 01805 - 92 20 9
14 ct/called minute from the Deutsche Telekom AG fixed network, from mobile phones a maximum of 42 ct/minute.
6. REPAIRS
ATTENTION
Repairs are only to be carried out by specialists specifically trained for this.
Given damage the appliance is to be repaired or replaced by the manufacturer.
7. FUNCTIONAL CHECK • MAINTENANCE • CARE
To ensure safety, the recirculation filter attachment should be serviced at least once a year and its function
checked by a specialist. At the same time, the built-in filter unit must be replaced at least once a year, and
immediately when the saturation limit is reached.
The functionality is checked electronically by the integrated ventilation and filter saturation monitoring, so that
a function check of the recirculation filter attachment is carried out permanently during operation. The activat-
ed charcoal main filter of the recirculation filter attachment must be replaced with a new filter at short notice
if the corresponding maintenance indicator (red screen) is shown. The filter can only be replaced by one of
our trained service technicians and must be requested promptly on the service hotline. Filter replacement by
asecos service personnel ensures that the contaminated activated carbon is fed into a defined disposal chain.
7.1. SENSORS AND MONITORING ELECTRONICS
The UFA contains sensitive sensors and complex monitoring electronics. The device must be designed as a
“continuous 24/7" and was also designed for this purpose. The sensitive gas sensor system in particular is
heavily stressed by continuous operation and, according to experience, can deliver unreliable measurement
results after a certain period of operation (drift) after approx. 40,000 operating hours.
The UFA can then no longer be used safely (possible monitoring errors).
In this case, a visual warning is given. In this case, please contact the customer service for replacement of the
sensor unit.
7.2. CLEANING
For external cleaning of the recirculating air filter attachment, please use common, mild household cleaners
and a soft cloth.
Disconnect your recirculating air filter attachment from the mains by unplugging
the power cable before cleaning! Make sure that no moisture gets into the inside of the recircu-