asecos UFA.025.030 User Manual Download Page 10

10

EN

8. TECHNICAL DATA

UFA.025.030

UFA.025.030.XL

External dimensions W x D x H

mm

308 x 555 x 256

308 x 555 x 256

Nominal voltage

V

85-265

85-265

Frequency

Hz

50/60

50/60

Weight

kg

17

19

Power consumption in operation

W

8,5

8,5

Maximum current consumption

A

0.13

0.13

Max. volume flow

m³/h

10

17

Min. volume flow

m³/h

10

17

Emission sound pressure level

dB

23.0

23.0

Potential-free alarm contact: maximum continous current

A

10

10

Potential-free alarm contact: maximun nominal voltage AC

V

230

230

Potential-free alarm contact: maximum nominal voltage DC

V

30

30

Potential-free alarm contact: single-phase motor load

W

185

185

Potential-free alarm contact: max. switching capacity (electromagnetic)

VA

300

300

Potential-free alarm contact: max. switching capacity (ohmic)

VA

1500

1500

* including adapter

PLEASE NOTE 

The data are approximate values and as such are not to be used in the sense of guaranteed properties. 
They correspond to the state of the art at the time of publication of the operating instructions. Further 
technical development expressly permits changes to these values without prior notice.

9. TECHNICAL DRAWING

1

2

4

3

5

1

2

5

3

4

5

45

 Ø 75

45

38

(256)

211

151

ventilator

Sensor

activated carbon filter

Activated carbon 

secondary filter

Potential-free alarm 

contact

Fresh air

Cleaned exhaust air

Summary of Contents for UFA.025.030

Page 1: ...EN EP V 34660 01 05 2022 USER MANUAL Recirculating air filter unit UFA 025 030 XL...

Page 2: ...ting monitoring 4 2 5 Potential free alarm contact 5 3 ERECTION COMMISSIONING 5 3 1 Commissioning 5 3 2 Self test 6 4 DISPLAY AND MENU 6 4 1 Power indicator 6 4 2 Overview of the menu icons 7 4 3 Show...

Page 3: ...ELOPMENT AND MANUFACTURER asecos GmbH Weiherfeldsiedlung 16 18 63584 Gr ndau Germany The type plate with the serial number is located on the outside of the unit s housing 1 4 PURPOSE OF USE The unit i...

Page 4: ...ther materials are to be stored Safe and faultless function is shown by the ventilation and filter monitoring mechanism which is fitted as standard 3 2 ventilator 2 4 VENTILATION SETTING MONITORING Th...

Page 5: ...nternal alarm contact Connector External connection Contact position Normal operation L and 1 are connected Alarm or mains failure L and 2 are connected CAUTION The potential free alarm contact must n...

Page 6: ...begins during which all safety relevant compo nents are checked If there is a fault the unit will not start An error F7 is displayed alternating with the relevant faulty safety element F1 F4 4 DISPLAY...

Page 7: ...y Symbols in the Settings menu and sub items Set contrast Carry out filter change Set air monitoring parameters Replace sensor Exit current display 4 3 SHOW SYSTEM INFORMATION ATTENTION For a simplifi...

Page 8: ...fan has been switched off It is now imperative to change the filter at short notice Main filter and secondary filter change necessary Please contact your specialist dealer or our service hotline 01805...

Page 9: ...toring so that a function check of the recirculation filter attachment is carried out permanently during operation The activat ed charcoal main filter of the recirculation filter attachment must be re...

Page 10: ...DC V 30 30 Potential free alarm contact single phase motor load W 185 185 Potential free alarm contact max switching capacity electromagnetic VA 300 300 Potential free alarm contact max switching capa...

Page 11: ...in undisturbed operation nA non functioning 4 Explosion groups according to EN 60079 0 2019 09 IIB the group has a limiting gap width MESG 0 5 0 9 mm suitable e g for use with ethylene 5 Unit categori...

Page 12: ...Perp tua de Mogoda Barcelona 34 902 300385 34 902 300395 info asecos es asecos bv Veiligheid en milieubescherming Tuinderij 15 NL 2451 GG Leimuiden 31 172 506476 31 172 506541 info asecos nl asecos S...

Reviews: