AC55LC-3, AC63LC-3, and AC75LC-3 Operations Manual....
34
6.3
AUTO-RESTART FEATURE
The Auto-Restart feature will safely and automatically bring the shore power converter back on-
line following a power failure and recovery event. Highlights include:
Automatically routes power from the dock to the ships power buss.
Front panel controls allow auto-restart to be enabled or disabled.
Auto-Restart status displayed on the LCD STATUS screen.
Fault tolerant to guarantee safe operation.
Valid shore power verified prior to restart.
Handles repeated power failures without operator intervention.
LETHAL VOLTAGES ARE AUTOMATICALLY ROUTED WITHIN THE CONVERTER
WHEN (1) INPUT POWER IS PRESENT, (2) THE DISCONNECT SWITCH IS IN THE
“ON” POSITION, AND (3) AUTO-RESTART IS ENABLED.
LETHAL VOLTAGES WILL BE AUTOMATICALLY ROUTED TO THE CONVERTER
OUTPUT AND THE OUTPUT CONTACTOR WILL AUTOMATICALLY CLOSE
WHEN (1)
INPUT POWER IS PRESENT, (2) THE DISCONNECT SWITCH IS IN THE “ON”
POSITION, AND (3) AUTO-RESTART IS ENABLED.
NEVER REMOVE ANY PANELS OR COVERS WITHOUT SECURING (REMOVING)
SHORE POWER WHEN AUTO-RESTART IS ENABLED.
NEVER PERFORM MAINTENANCE OR SERVICE WHILE AUTO-RESTART IS
ENABLED.
NEVER ASSUME AUTO-RESTART IS DISABLED.
NEVER USER THE DISCONNECT SWITCH TO TURN THE CONVERTER OFF WITH
AUTO-RESTART ENABLED. THE CONVERTER CANNOT DISTINGUISH BETWEEN A
VALID POWER FAILURE AND IMPROPER USE OF THE DISCONNECT SWITCH.
Summary of Contents for AC55LC-3
Page 42: ...AC55LC 3 AC63LC 3 and AC75LC 3 Operations Manual 42 This page intentionally left blank ...
Page 62: ...AC55LC 3 AC63LC 3 and AC75LC 3 Operations Manual 62 11 MSDS SHEET COOLANT OIL ...
Page 63: ...AC55LC 3 AC63LC 3 and AC75LC 3 Operations Manual 63 11 MSDS SHEET COOLANT OIL cont ...
Page 64: ...AC55LC 3 AC63LC 3 and AC75LC 3 Operations Manual 64 11 MSDS SHEET COOLANT OIL cont ...
Page 65: ...AC55LC 3 AC63LC 3 and AC75LC 3 Operations Manual 65 11 MSDS SHEET COOLANT OIL cont ...
Page 66: ...AC55LC 3 AC63LC 3 and AC75LC 3 Operations Manual 66 11 MSDS SHEET COOLANT OIL cont ...
Page 67: ...AC55LC 3 AC63LC 3 and AC75LC 3 Operations Manual 67 11 MSDS SHEET COOLANT OIL cont ...
Page 68: ...AC55LC 3 AC63LC 3 and AC75LC 3 Operations Manual 68 11 MSDS SHEET COOLANT OIL cont ...