Z31Y  Z31SY

 

DIGITAL ELECTRONIC

REFRIGERATION UNITS

CONTROLLER

OPERATING INSTRUCTIONS

Vr. 02 (ENG) - 04/12 - cod.: ISTR-MZ31YENG02

ASCON TECNOLOGIC S.r.l.

VIA INDIPENDENZA 56

27029 VIGEVANO (PV) ITALY

TEL.:  +39 0381 69871

FAX: +39 0381 698730

http:\\www.ascontecnologic.com

e-mail: [email protected]

FOREWORD

This manual contains the information
necessary for the product to be installed
correctly and also instructions for its
maintenance and use; we therefore recommend
that the utmost attention is paid to the following

instructions and to save it.
This document is the exclusive property of ASCON
TECNOLOGIC which forbids any reproduction and divulgation
, even in part, of the document, unless expressly authorized. 
ASCONT ECNOLOGIC reserves the right to make any formal or
functional changes at any moment and without  any notice.
Whenever a failure or a malfunction of the device may cause
dangerous situations for persons, thing or animals, please
remember that the plant has to be equipped with additional
devices which will guarantee safety.
ASCON TECNOLOGIC and its legal representatives do not
assume any responsibility for any damage to people, things or
animals deriving from violation, wrong or improper use or in
any case not in compliance with the instrument’s features.

INDEX

INSTRUMENT ORDERING CODE

7.5

FUNCTIONAL DATA

7.4

MECHANICAL DIMENSIONS, PANEL CUT-OUT AND
MOUNTING

7.3

MECHANICAL DATA

7.2

ELECTRICAL DATA

7.1

TECHNICAL DATA

7

GUARANTEE AND REPAIRS

6.3

CLEANING

6.2

SIGNALLING

6.1

PROBLEMS , MAINTENANCE AND GUARANTEE

6

PROGRAMMABLE PARAMETERS TABLE

5

PARAMETERS CONFIGURATION BY “A01”

4.12.3

RS 485 SERIAL INTERFACE BY “TLCNV”

4.12.2

“TVR Y”  REMOTE DISPLAY

4.12.1

PARAMETERS CONFIGURATION BY “A01”

4.12

FUNCTION OF KEYS “U” AND “DOWN/AUX”

4.11

OPEN DOOR ALARM

4.10.3

EXTERNAL ALARM (DIGITAL INPUT)

4.10.2

TEMPERATURE ALARMS

4.10.1

ALARM FUNCTIONS

4.10

EVAPORATOR FANS CONTROL

4.9

DEFROST DISPLAY LOCK

4.8.4

END DEFROST

4.8.3

MANUAL DEFROST

4.8.2

AUTOMATIC DEFROST STARTS

4.8.1

DEFROST CONTROL

4.8

COMPRESSOR PROTECTION FUNCTION AND DELAY
AT POWER-ON

4.7

TEMPERATURE CONTROL

4.6

ACTIVE SET POINT SELECTION

4.5

OUTPUTS AND BUZZER CONFIGURATION

4.4

DIGITAL INPUT

4.3

MEASURING AND VISUALIZATION

4.2

ON / STAND-BY FUNCTION

4.1

FUNCTIONS

4

ELECTRICAL WIRING DIAGRAM

3.4

ELECTRICAL CONNECTIONS

3.3

MECHANICAL MOUNTING

3.2

PERMITTED USE

3.1

INFORMATION ON INSTALLATION AND USE 

3

KEYBOARD LOCK FUNCTION

2.6

RESET PARAMETERS TO DEFAULT VALUE/LEVEL

2.5

CUSTOMIZED MODE PARAMETER PROGRAMMING 
(PARAMETERS PROGRAMMING LEVEL)

2.4

PARAMETER PROTECTION USING THE PASSWORD

2.3

STANDARD MODE  PARAMETERS PROGRAMMING 

2.2

FAST PROGRAMMING OF SET POINT

2.1

PROGRAMMING

2

FRONT PANEL DESCRIPTION

1.2

GENERAL DESCRIPTION

1.1

INSTRUMENT DESCRIPTION

1

1 - INSTRUMENT DESCRIPTION

1.1 - GENERAL DESCRIPTION

The model 

Z31Y

 is a digital controller with microprocessor that is

typically used in cooling applications that have temperature control
with ON/OFF regulation and defrosting control at intervals time or
at reaching temperature by stopping compressor or by means of
electrical heating or hot gas/reverse cycle.
The instrument has up to 2 relay outputs, up to 2 inputs for PTC or
NTC temperature probes and a digital input (aternative to an
temperature input), in addition can be equipped with an internal
buzzer that is the sound system for alarms.
The 2 outputs can be can all be configured for controlling the
compressor or the temperature control device and the defrosting
device or ,alternatively any of the previous functions,  the
evaporation fan or using an auxiliary device or an alarm.
The 2 inputs for temperature probes can be used to measure the
control temperature, the evaporator temperature, products or aux
temperature,  while the digital input alternative to evaporator or aux

ASCON TECNOLOGIC - Z31Y 

 

- OPERATING INSTRUCTIONS - Vr. 02 - 04/12 -  ISTR-MZ31YENG02 -  PAG. 1

Summary of Contents for Z31SY

Page 1: ...4 10 1 ALARM FUNCTIONS 4 10 EVAPORATOR FANS CONTROL 4 9 DEFROST DISPLAY LOCK 4 8 4 END DEFROST 4 8 3 MANUAL DEFROST 4 8 2 AUTOMATIC DEFROST STARTS 4 8 1 DEFROST CONTROL 4 8 COMPRESSOR PROTECTION FUNCT...

Page 2: ...status on off off and silenced or memorized flashing 11 Led AUX Indicates AUX output status on on off off or inhibited flashing 12 Led Stand By Indicate the Stand by status 2 PROGRAMMING 2 1 FAST PROG...

Page 3: ...identifiable by the printed code 103AT 11 visible on the sensor part is compliant with standard EN 13485 Thermometers for measuring the air and product temperature for the transport storage and distr...

Page 4: ...nt is switched off peak values are always re set However it is also possible to reset these values if the instrument is switched on by using the DOWN key hold for 3 sec during peak visualization The d...

Page 5: ...put will be on in normal mode Set Point SP active and off in economy mode operation Set Point SP2 active 4 Internal Light output managed by digital input This output will be on when door is opened i F...

Page 6: ...lts that currently used in the refrigerators systems ct intervals with counts only the compressor function time output ot switched on Mode typically used in the positive temperature refrigerators syst...

Page 7: ...1 differential Hysteresis The active defrost is shown on the instrument display with the lighting up of the DEFROST led At the end of defrosting it is possible to delay the new start up of the compre...

Page 8: ...s the alarm signal when the alarm status ends To cancel the alarm memory signal press any key It must be remembered that if an output function is desired with an alarm memory An or An it is necessary...

Page 9: ...cessary that the device or instrument are being supplied USB SUPPLY AC SUPPLY SUPPLY ADAPTER 12 VDC USB For additional info please have a look at the A01 instruction manual 4 12 2 TVRY REMOTE DISPLAY...

Page 10: ...obe Calibration i C2 10 oF oF 0 01 9 59 min sec Fan delay after defrost F Fd 37 oF oF on Fan status during defrost F FE 36 1 0 0 0 30 0 C F Differential fan control F dF 35 99 9 99 9 999 C F Low tempe...

Page 11: ...rs relative to compressor protection and power on delay 99 5 min sec x10 1 0 255 MODBUS Station address for serial communication t AS 60 oF oF 999 Access Password to parameter functions t PP 59 oF oF...

Page 12: ...21 990 25 C or NTC 103AT 2 10K 25 C 1 digital input for free voltage contacts alternative to Pr2 input Output s up to 2 relay outputs 5 A Res 6 4 A 8 3 A Out2 SPDT 8A 1 2HP 250V 1 3HP 125 VAC 12 A Res...

Page 13: ...1000 4 4 2KV supply and relay outputs 1KV inputs EN61000 4 5 supply 2KV com mode 1 KV diff mode EN61000 4 6 3V Directive 2006 95 CE EN 60730 1 EN 60730 2 9 Regulation 37 2005 CE EN13485 air S A 2 50 C...