Sigma
due
- sigmaPAC CU-02 -
User manual
14
3-2-7
CPU Setup Menu
Figure 3.8 - CPU Setup Menu
Startup Timeout Setup:
To set the startup timeouts;
Persistency Setup:
To set the parameters that control the saving of PLC pro-
gram in the retentive memory;
CLOCK Setup:
To set the parameters of the CPU real time clock;
Exit:
To exit this menu and return to the previous menu.
3-2-8
Startup Setup Menu
Figure 3.9 - Startup Setup Menu
Startup Timeout:
To set the Startup Timeout;
Inactivity Timeout:
To set the Inactivity Timeout;
DO1 used by watchdog
If enabled, the digital output DO1 could be connected to
a software function block to signal a watchdog event
Exit:
To exit this menu and return to the previous one;
To change the value of an item, the user has to select the item number and press
ENTER. The screen will then change, asking the user to “
insert new value:
”.
CPU SETUP MENU
1. Startup Timeout Setup
2. Persistency Setup
3. Clock Setup
4. Exit
Enter Selection:
Ascon S.p.a.
SigmaPAC Control Unit CU-02
Device configuration
STARTUP TIMEOUT MENU
Ascon S.p.a.
SigmaPAC Control Unit CU-02
Device configuration
1. Startup Timeout (2..120s): 10
2. Inactivity Timeout (2..120s): 30
3. DO1 used for watchdog (0..1): Disabled
4. Exit
Enter Selection: