INCORRECT  INSTALLATIONS

P: 1800 807 604    
F: 1800 807 609   
E: [email protected]

© Ascento Group Australia, 2016

INCORRECT! 

PUMP IS INSTALLED 

WITHOUT BARREL UNION’S, CHECKVALVE 

Y-STRAINER & A BALL VALVE.

!

DIAGRAM 3

INCORRECT!

VSRM PUMP IS 

NOT SUITABLE 

FOR SUCTION 

LIFT.

!

WRONG!

DIAGRAM 4

WRONG!

CORRECT  INSTALLATIONS

(1)

BARREL UNION

(2)

Y-STRAINER OR PRE-FILTER

(3)

BALL VALVE OR GATE VALVE

(4) SWING 

CHECK VALVE

(5)

PRESSURE TANK 

(5)

MIN

100mm

(1)

(2)

(3)

KEY

ALWAYS INSTALL YOUR PUMP ON A LEVEL CONCRETE OR PAVED SURFACE!

DIAGRAM 1

DIAGRAM 2

IMPORTANT!

 CLEAN THE Y-STRAINER MONTHLY TO ENSURE PEAK 

PERFORMANCE. SIMPLY UNDO THE BUNG AND LET IT FLUSH OUT. 

MAKE SURE YOU RE-FIT THE MESH FILTER.

TIP!

 IF PUMP STARTS FREQUENTLY, 

THERE IS MOST LIKELY SOMETHING 

LEAKING, IT WILL NOT BE A PUMP FAULT. 

ALL VSRM PUMPS 

MUST HAVE A 

CHECKVALVE 

INSTALLED IN THE 

SUCTION PIPE. 

WARNING!

WARNING! VSRM PUMPS MUST NOT BE USED FOR SUCTION LIFT.

(4)

(1)

Model

Recommended Pressure 

Setting – flooded suction

Max Pressure setting - 

flooded suction

Max Pressure setting - Mains boosting

VSRM38-72

2.5Bar

3.0Bar

3.0Bar above existing mains pressure (cannot exceed 10.0Bar)

VSRM48-72

3.1Bar

4.0Bar

4.0Bar above existing mains pressure (cannot exceed 10.0Bar)

VSRM39-102

2.6Bar

3.0Bar

3.0Bar above existing mains pressure (cannot exceed 10.0Bar)

VSRM58-102

3.7Bar

4.9Bar

4.9Bar above existing mains pressure (cannot exceed 10.0Bar)

VSRM50-270

3.9Bar

4.2Bar

4.0Bar above existing mains pressure (cannot exceed 10.0Bar)

IMPORTANT RE PRESSURE SETTINGS:  

The higher the Pressure setting (“Setting Pressure” on the pump control panel) the more power 

you will use – set the pressure at the lowest pressure that is acceptable for the application.  The recommended setting is 65% of the max 
head pressure and the MAXIMUM settings is 80% of the max head pressure (refer to the label on the pump and also the table below)   IF 
THE PRESSURE IS SET TOO HIGH THE PUMP WILL RUN CONTINUOUSLY – this will cost you a lot of wasted power and void the warranty.  

REEFE® VSRM INVERTER 

CONSTANT PRESSURE SYSTEM