MAINS / TOWN SUPPLY
DISCHARGE
TO HOUSE
REEFE® VSRM
SERIES VARIABLE
SPEED PRESSURE
PUMP
DUAL
CHECK
VALVE
BALL
VALVE
BARREL UNION
IMPORTANT
• The pump must be installed
between the water meter and
the first point of discharge.
• This set up is designed so that
the pump does not need to
start for minor use - saving
the owner money through
reduced running costs.
• Set the pressure of the pump
as:
MAINS PR
INCREASE DESIRED* =
SETTING PRESSURE
• *Note: The “increase desired”
must not exceed the suggest-
ed maximum operating pres-
sure for the pump, or it will
never turn off! See diagam-
matic installation instructions
for VSRM pumps.
MAINS WATER PRESSURE
BOOSTING SYSTEM
Installation Guide
Ascento Group Australia
•
REEFE Pumps
37 Export St LYTTON Q 4178
Phone 1800 807 604 Fax 1800 807 609
Email [email protected] Visit www.reefe.com.au
IMPORTANT:
It is the installers responsibility to ensure compliance with all applicable Plumbing and Electrical Regulations.
NOTES
1) Total pressure must
not exceed the pumps
stated maximum.
2) This configuration
is also acceptable for
other pumps with
pressure switch setup.