2) Prepare a twisted pair Ethernet cable with RJ-45 plugs on each end. Use Cat 3, 4 or 5 cable 
for standard 10Mbps Ethernet connections, or Cat 5 cable for 100Mbps Fast Ethernet 
connections.

 

3) Plug one end of the cable into the PC's NIC and plug the other end into any RJ-45 port of 
the AT-52-EDFA series. All the AT-52-EDFA RJ-45 port supports both 10Mbps and 100Mbps 
Ethernet connections. Ensure that the plug's locking tab clicks into proper position to make 
good access.

 

Caution: Do not plug a phone jack connector into the RJ-45 port. This may damage the EDFA. 
Instead, use only twisted-pair cables with RJ-45 connectors that conform to FCC standards.

 

Note:

 

1) Connect other compatible AT-52-EDFA series or network hub, adopt direct or across cable 
to connect MDI port in other device.

 

2) Ensure that the twisted pair cable length does not exceed 100 meters.

 

3) Cat 5 cable is recommended for all network connections to avoid confusion or 
inconvenience, when upgrading to Fast Ethernet devices in the future.

 

4) Cascade length provision: IEEE 802.3 standard prescribes that through twisted pair at most 
4 hub (such as repeaters) can be cascade, and IEEE 802.3u standard has more strict order for 
high-speed Ethernet. So, when cascade device except for this AT-52-EDFA series, please 
following the above connection regulation. But please pay attention because AT-52-EDFA 
series divide the connected path into unattached port, don’t reckon in the AT-52-EDFA series 
or connected cable related device in cascade length.

 

 

Connection Management (Out-Band)

 

Remote management can be performed through the dedicated LAN port (10/100BASE-TX 
port) on the front of the AT-52-EDFA or any 10/100BASE port of AT-52-EDFA.

 

Before the Management port be accessed through LAN port, please configure the IP address 
and subnet mask by serial port according to network configuration requirement.

 

 

 

Port Description

 

 

Figure DB9 interface 

DB9 interface is a standard connector used in RS232 in series communication connects. OLT 
adopt 9 pin standard connector which is the same as the connector of PC Com interface.

 

1

 

8

 

Summary of Contents for AT5200 FTTX EDFA

Page 1: ...ACT AT5200 FTTX Multiport EDFA Quick Reference Guide Revision H...

Page 2: ...forbidden This document is produced to assist professional and properly trained personnel with installation and maintenance issues for the product The capabilities system requirements and or compatib...

Page 3: ...ion 9 3 3 Power and Cooling Requirements 9 3 4 Module Installation and Adjustment 10 3 5 Front Panel Layout Layout May Vary 11 3 6 Rear Panel Layouts 12 4 Technical Description 13 4 1 Overview 13 4 2...

Page 4: ...optical connectors when not in use The typical connectors fitted are SC APC 8 Note 8 angle polished connectors must be used Cleaning Use only a damp cloth for cleaning the front panel Use a soft dry...

Page 5: ...up to 16 output ports in 1RU setting and 64 output ports in 2RU setting Combined with our AT5000 1550nm direct or externally modulated laser transmitter MSOs can quickly deploy and activate advanced...

Page 6: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 6 of 29 Application Diagram...

Page 7: ...Insertion Loss Transmission band 0 8dB Reflection band 0 6dB Polarization Dependence Loss dB 0 1 Polarization Dependence Gain dB 0 4 Polarization Mode Dispersion ps 0 1 Input Output Isolation dB 40 Ec...

Page 8: ...port EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 8 of 29 The maximum output power per port is 26dBm Output power is measured after WDM Contact ACT Sales Representative for...

Page 9: ...n and the system will recover automatically The unit should be located in an environment not exceeding a temperature range from 0 to 50 C The internal temperature should never reach 70 C If the temper...

Page 10: ...rts to the system Always place protective dust caps on all optical ports when not in use Connect the optical input signal to the input port of the EDFA Ensure the input optical power is within the ran...

Page 11: ...aking selections with the user interface ENT Button Start the menu by pushing ENT first refer to 5 2 4 5 6 LASER ON OFF OPT IN Dual OPT IN optional OPT OUT Key switch for laser activation Optical inpu...

Page 12: ...ut power 90 to 265 Vac 50 60 Hz fused IEC input includes spare fuse Or 30 to 72 VDC input Inputs 1 to 2 for power redundancy IEC Main Input Power 2 Optional Special order Mains input power 90 to 265 V...

Page 13: ...s shown in Section 3 5 The Optical Gain Block has an input optical signal range of 10 to 10dBm for which the output will be stable at its nominated optical power Although the pump lasers will operate...

Page 14: ...3 Pressing ENT bottom to display parameters 4 If any fault listed above occurred there will be an alarm Red flashing Microprocessor will shut off the laser pump automatically and digital panel will sh...

Page 15: ...eset these in case of a power failure The factory default setting of the unit is to have an IP address of 192 168 1 50 The factory default setting is to have the laser switched off for all models LCD...

Page 16: ...net mask R GW Adjustable list display the gateway address S TR1 Adjustable list display the TRAP1 address T TR2 Adjustable list display the TRAP2 address U LCD Contrast Level Adjustable list display t...

Page 17: ...ement ports RS232 port be suitable for examining AT 52 EDFA parameters and some system configuration by PC machine RS232 port SNMP Simple network management protocol Before connection AT 52 EDFA serie...

Page 18: ...8 Nonuse Nonuse RJ 45 Pin assignment Straight Cross AT 52 EDFA Adapter AT 52 EDFA HUB AT 52 EDFA 1 IRD 1 OTD 1 IRD 1 IRD 2 IRD 2 OTD 2 IRD 2 IRD 3 OTD 3 IRD 3 OTD 3 OTD 6 OTD 6 IRD 6 OTD 6 OTD Straig...

Page 19: ...r all network connections to avoid confusion or inconvenience when upgrading to Fast Ethernet devices in the future 4 Cascade length provision IEEE 802 3 standard prescribes that through twisted pair...

Page 20: ...DB9 connector in AT 52 EDFA series and PC side According to the following steps to connect cables 1 Through RS232 DB9 cable connect a super terminal program PC to RS232 port in AT 52 EDFA series back...

Page 21: ...e web browser to check the working condition and basic parameters of the amplifier it supports IE Chrome Firefox opera and other main web browser The following example are based on Opera browser 1 Fin...

Page 22: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 22 of 29...

Page 23: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 23 of 29 2 Open web browser input the IP add For example 192 168 0 22 Then login version...

Page 24: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 24 of 29 User Name admin Password 123456 3 The working condition version...

Page 25: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 25 of 29 4 Items guide on the left click to enter...

Page 26: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 26 of 29...

Page 27: ...AT5200 FTTX Multiport EDFA Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 27 of 29...

Page 28: ...duce the amplifier s performance and can result in permanent damage to the device It is recommended that the fiber connectors be cleaned prior to connection or reconnection to the system No lights ON...

Page 29: ...Unit 1907 600 Luban Road 2710 Thomes Ave 200023 Shanghai CHINA Cheyenne WY 82001 USA Phone 86 21 60232616 Phone 1 203 816 5188 EUROPE VIETNAM Pfarrer Bensheimer Strasse 7a 15 F TTC Building Duy Tan S...

Reviews: